van Lummel, Rob C. [1 ,2 ]
Walgaard, Stefan [1 ]
Hobert, Markus A. [3 ,4 ,5 ]
Maetzler, Walter [3 ,4 ,5 ]
van Dieen, Jaap H. [2 ]
Galindo-Garre, Francisca [6 ,7 ]
Terwee, Caroline B. [6 ,7 ]
机构
[1] McRoberts BV, The Hague, Netherlands
[2] Vrije Univ Amsterdam, Dept Human Movement Sci, MOVE Res Inst Amsterdam, Amsterdam, Netherlands
[3] Univ Tubingen, Ctr Neurol, Tubingen, Germany
[4] Univ Tubingen, Dept Neurodegenerat, Hertie Inst Clin Brain Res, Tubingen, Germany
[5] German Ctr Neurodegenerat Dis, DZNE, Tubingen, Germany
[6] Vrije Univ Amsterdam, Med Ctr, Dept Epidemiol & Biostat, Amsterdam, Netherlands
[7] Vrije Univ Amsterdam, Med Ctr, EMGO Inst Hlth & Care Res, Amsterdam, Netherlands
来源
PLOS ONE | 2016年 / 11卷 / 03期
关键词
FUNCTIONAL REACH; STAND; PERFORMANCE; VALIDITY; BALANCE; PEOPLE;
D O I
10.1371/journal.pone.0151881
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background The "Timed Up and Go" (TUG) is a widely used measure of physical functioning in older people and in neurological populations, including Parkinson's Disease. When using an inertial sensor measurement system (instrumented TUG [iTUG]), the individual components of the iTUG and the trunk kinematics can be measured separately, which may provide relevant additional information. Objective The aim of this study was to determine intra-rater, inter-rater and test-retest reliability of the iTUG in patients with Parkinson's Disease. Methods Twenty eight PD patients, aged 50 years or older, were included. For the iTUG the DynaPort Hybrid (McRoberts, The Hague, The Netherlands) was worn at the lower back. The device measured acceleration and angular velocity in three directions at a rate of 100 samples/s. Patients performed the iTUG five times on two consecutive days. Repeated measurements by the same rater on the same day were used to calculate intra-rater reliability. Repeated measurements by different raters on the same day were used to calculate intra-rater and inter-rater reliability. Repeated measurements by the same rater on different days were used to calculate test-retest reliability. Results Nineteen ICC values (15%) were >= 0.9 which is considered as excellent reliability. Sixty four ICC values (49%) were >= 0.70 and <0.90 which is considered as good reliability. Thirty one ICC values (24%) were >= 0.50 and < 0.70, indicating moderate reliability. Sixteen ICC values (12%) were >= 0.30 and < 0.50 indicating poor reliability. Two ICT values (2%) were < 0.30 indicating very poor reliability. Conclusions In conclusion, in patients with Parkinson's disease the intra-rater, inter-rater, and test-retest reliability of the individual components of the instrumented TUG (iTUG) was excellent to good for total duration and for turning durations, and good to low for the sub durations and for the kinematics of the SiSt and StSi. The results of this fully automated analysis of instrumented TUG movements demonstrate that several reliable TUG parameters can be identified that provide a basis for a more precise, quantitative use of the TUG test, in clinical practice.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Inter-rater, intra-rater, and test-retest reliability of photonumeric grading scales using photographs
    Korgavkar, K.
    Weinstock, M. A.
    Lee, K.
    [J]. JOURNAL OF INVESTIGATIVE DERMATOLOGY, 2017, 137 (05) : S29 - S29
  • [2] TEST-RETEST AND INTER-RATER RELIABILITY OF THE 20-METER AMBULATION TEST IN PATIENTS WITH PARKINSON?S DISEASE
    Hutin, Emilie
    Ghedira, Mouna
    Mardale, Valentina
    Boutou, Mina
    Santiago, Tharaga
    Joudoux, Sandrine
    Gault-Colas, Caroline
    Gracies, Jean-Michel
    Bayle, Nicolas
    [J]. JOURNAL OF REHABILITATION MEDICINE, 2023, 55
  • [3] Imagined Timed Up and Go test (iTUG) in people with Parkinson's Disease: test-retest reliability and validity
    Moreno-Verdu, Marcos
    del Rosario Ferreira-Sanchez, Maria
    Martin-Casas, Patricia
    Atin-Arratibel, Maria Angeles
    [J]. DISABILITY AND REHABILITATION, 2024, 46 (05) : 1005 - 1015
  • [4] Test-retest intra-rater reliability of grip force in patients with stroke
    Hammer, A
    Lindmark, B
    [J]. JOURNAL OF REHABILITATION MEDICINE, 2003, 35 (04) : 189 - 194
  • [5] Inter-rater and intra-rater reliability of the extended TUG test in elderly participants
    Bedoya-Belmonte, Juan Jose
    Rodriguez-Gonzalez, Maria del Mar
    Gonzalez-Sanchez, Manuel
    Pitarch, Jose Miguel Barreda
    Galan-Mercant, Alejandro
    Cuesta-Vargas, Antonio I.
    [J]. BMC GERIATRICS, 2020, 20 (01)
  • [6] The functional analysis checklist: Inter-rater and test-retest reliability
    Sturmey, P
    [J]. JOURNAL OF APPLIED RESEARCH IN INTELLECTUAL DISABILITIES, 2001, 14 (02) : 141 - 146
  • [7] Test-retest, inter- and intra-rater reliability of the flexicurve for evaluation of the spine in children
    Sedrez, Juliana A.
    Candotti, Claudia T.
    Rosa, Maria I. Z.
    Medeiros, Fernanda S.
    Marques, Mariana T.
    Loss, Jefferson F.
    [J]. BRAZILIAN JOURNAL OF PHYSICAL THERAPY, 2016, 20 (02) : 142 - 147
  • [8] Inter-Rater Reliability and Intra-Rater Reliability of Assessing the 2-Minute Push-Up Test
    Fielitz, Lynn
    Coelho, Jeffrey
    Horne, Thomas
    Brechue, William
    [J]. MILITARY MEDICINE, 2016, 181 (02) : 167 - 172
  • [9] Test-retest, intra- and inter-rater reliability of the reactive balance test in patients with chronic ankle instability
    Maricot, Alexandre
    Lathouwers, Elke
    Verschueren, Jo
    De Pauw, Kevin
    Meeusen, Romain
    Roelands, Bart
    Tassignon, Bruno
    [J]. FRONTIERS IN NEUROLOGY, 2024, 15
  • [10] Intra-rater reliability of timed 'up and go' test for children diagnosed with cerebral palsy
    Sanjivani, Dhote
    Prema, Khatri
    [J]. INTERNATIONAL JOURNAL OF THERAPY AND REHABILITATION, 2012, 19 (10): : 575 - 580