MEASURING ACTIVITY IN PATIENTS WITH SARCOIDOSIS - A PILOT TRIAL OF TWO WRIST-WORN ACCELEROMETER DEVICES

被引:0
|
作者
Atkins, Christopher P. [1 ,2 ]
Jones, Andy P. [1 ]
Wilson, Andrew M. [1 ,2 ]
机构
[1] Univ East Anglia, Norwich Med Sch, Norwich NR4 7TJ, Norfolk, England
[2] Norfolk & Norwich Univ Hosp, Colney Lane, Norwich NR4 7UQ, Norfolk, England
关键词
sarcoidosis; activity; accelerometers; PHYSICAL-ACTIVITY; SEDENTARY BEHAVIOR; UNITED-STATES; FATIGUE; FEATURES; TIME; HIP;
D O I
暂无
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Introduction: Increasing physical activity is associated with health benefits. Reduced physical activity has been noted in sarcoidosis, particularly where fatigue co-exists. Monitoring physical activity is possible with wrist-worn devices. This study compared two available devices to determine patient preference and compare wear-time, with a secondary outcome of comparing device outputs with fatigue scores. Methods: Patients with sarcoidosis wore two wrist-worn activity monitors (GENEActiv actiwatch and Actigraph GT3X-bt) separately for seven days each. Participants were randomly allocated to receive either device first. Participants completed the Fatigue Assessment Scale (FAS) questionnaire immediately before wearing the first device. All participants completed a questionnaire of their perception regarding each device after the wear period. Data from the devices was analysed for total wear time, time spent in moderate or vigorous activity (MVPA) and for time spent in sedentary behaviours. Results: Twelve patients with sarcoidosis were included. The GENEActiv device was preferred by ten (83.3%) participants. Wear time was greater with the GENEActiv device (1354 minutes/day vs 1079 minutes/day). Time spent in MVPA was slightly higher when recorded by the GENEActiv compared with the Actigraph. Moderately strong correlation was seen between FAS scores and sedentary time (r=-0.554), light activity (r=-0.585) and moderate activity (r=0.506). Discussion: A clear preference was demonstrated for the GENEActiv. This was reflected in higher wear time and suggests the device can be comfortably worn 24 hours per day. Data from this small cohort also suggests there is correlation between fatigue and activity scores in patients with sarcoidosis.
引用
收藏
页码:62 / 68
页数:7
相关论文
共 50 条
  • [41] Wrist-worn Versus Thigh-worn Accelerometers: Compliance And Participant Perspectives On Accelerometer Placement
    Hidde, Mary C.
    Bandera, Victoria
    Lyden, Kate
    Braun, Barry
    Leach, Heather J.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2021, 53 (08): : 233 - 233
  • [42] WRIST-WORN ACTIVITY MONITORING DEVICES OVERESTIMATE SLEEP DURATION AND EFFICIENCY IN HEALTHY ADULTS
    Jumabhoy, R.
    Dao, P. D.
    Maskevich, S.
    Stout, J. C.
    Drummond, S. P.
    SLEEP, 2017, 40 : A288 - A289
  • [43] Are Activity Wrist-Worn Devices Accurate for Determining Heart Rate during Intense Exercise?
    Martin-Escudero, Pilar
    Cabanas, Ana Maria
    Dotor-Castilla, Maria Luisa
    Galindo-Canales, Mercedes
    Miguel-Tobal, Francisco
    Fernandez-Perez, Cristina
    Fuentes-Ferrer, Manuel
    Giannetti, Romano
    BIOENGINEERING-BASEL, 2023, 10 (02):
  • [44] Estimating Free-living Physical Activity Using A Wrist-worn Actigraph Accelerometer: Can It Be Done?
    Petrucci, Greg J., Jr.
    Marcotte, Robert T.
    Cox, Melanna F.
    Staudenmayer, John
    Freedson, Patty S.
    Sirard, John R.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2019, 51 (06): : 164 - 165
  • [45] Understanding Same-Side Interactions with Wrist-Worn Devices
    Kerber, Frederic
    Lochtefeld, Markus
    Krueger, Antonio
    McIntosh, Jess
    McNeill, Charlie
    Fraser, Mike
    PROCEEDINGS OF THE NORDICHI '16: THE 9TH NORDIC CONFERENCE ON HUMAN-COMPUTER INTERACTION - GAME CHANGING DESIGN, 2016,
  • [46] Accuracy of wrist-worn wearable devices for determining exercise intensity
    Ho, Wei-Te
    Yang, Yi-Jen
    Li, Tung-Chou
    DIGITAL HEALTH, 2022, 8
  • [47] Can Wrist-Worn Medical Devices Correctly Identify Ovulation?
    Niggli, Angela
    Rothenbuhler, Martina
    Sachs, Maike
    Leeners, Brigitte
    SENSORS, 2023, 23 (24)
  • [48] WristRotate - A Personalized Motion Gesture Delimiter for Wrist-Worn Devices
    Kerber, Frederic
    Schardt, Philipp
    Loechtefeld, Markus
    PROCEEDINGS OF THE 14TH INTERNATIONAL CONFERENCE ON MOBILE AND UBIQUITOUS MULTIMEDIA (MUM 2015), 2015, : 218 - 222
  • [49] Multi-phased Step Detection Algorithm For A Wrist-worn Triaxial Accelerometer
    McCullough, Aston K.
    Tudor-Locke, Catrine
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2019, 51 (06): : 369 - 370
  • [50] Sedentary Sphere: Wrist-Worn Accelerometer-Brand Independent Posture Classification
    Rowlands, Alex V.
    Yates, Thomas
    Olds, Tim S.
    Davies, Melanie
    Khunti, Kamlesh
    Edwardson, Charlotte L.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2016, 48 (04): : 748 - 754