MEASURING ACTIVITY IN PATIENTS WITH SARCOIDOSIS - A PILOT TRIAL OF TWO WRIST-WORN ACCELEROMETER DEVICES

被引:0
|
作者
Atkins, Christopher P. [1 ,2 ]
Jones, Andy P. [1 ]
Wilson, Andrew M. [1 ,2 ]
机构
[1] Univ East Anglia, Norwich Med Sch, Norwich NR4 7TJ, Norfolk, England
[2] Norfolk & Norwich Univ Hosp, Colney Lane, Norwich NR4 7UQ, Norfolk, England
关键词
sarcoidosis; activity; accelerometers; PHYSICAL-ACTIVITY; SEDENTARY BEHAVIOR; UNITED-STATES; FATIGUE; FEATURES; TIME; HIP;
D O I
暂无
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Introduction: Increasing physical activity is associated with health benefits. Reduced physical activity has been noted in sarcoidosis, particularly where fatigue co-exists. Monitoring physical activity is possible with wrist-worn devices. This study compared two available devices to determine patient preference and compare wear-time, with a secondary outcome of comparing device outputs with fatigue scores. Methods: Patients with sarcoidosis wore two wrist-worn activity monitors (GENEActiv actiwatch and Actigraph GT3X-bt) separately for seven days each. Participants were randomly allocated to receive either device first. Participants completed the Fatigue Assessment Scale (FAS) questionnaire immediately before wearing the first device. All participants completed a questionnaire of their perception regarding each device after the wear period. Data from the devices was analysed for total wear time, time spent in moderate or vigorous activity (MVPA) and for time spent in sedentary behaviours. Results: Twelve patients with sarcoidosis were included. The GENEActiv device was preferred by ten (83.3%) participants. Wear time was greater with the GENEActiv device (1354 minutes/day vs 1079 minutes/day). Time spent in MVPA was slightly higher when recorded by the GENEActiv compared with the Actigraph. Moderately strong correlation was seen between FAS scores and sedentary time (r=-0.554), light activity (r=-0.585) and moderate activity (r=0.506). Discussion: A clear preference was demonstrated for the GENEActiv. This was reflected in higher wear time and suggests the device can be comfortably worn 24 hours per day. Data from this small cohort also suggests there is correlation between fatigue and activity scores in patients with sarcoidosis.
引用
收藏
页码:62 / 68
页数:7
相关论文
共 50 条
  • [31] Measuring Physical Activity in Spinal Cord Injury Using Wrist-Worn Accelerometers
    Murphy, Susan L.
    Kratz, Anna L.
    Zynda, Aaron J.
    AMERICAN JOURNAL OF OCCUPATIONAL THERAPY, 2019, 73 (01):
  • [32] Enabling Hand Gesture Customization on Wrist-Worn Devices
    Xu, Xuhai
    Gong, Jun
    Brum, Carolina
    Liang, Lilian
    Suh, Bongsoo
    Gupta, Shivam Kumar
    Agarwal, Yash
    Lindsey, Laurence
    Kang, Runchang
    Shahsavari, Behrooz
    Tu Nguyen
    Nieto, Heriberto
    Hudson, Scott E.
    Maalouf, Charlie
    Mousavi, Jax Seyed
    Laput, Gierad
    PROCEEDINGS OF THE 2022 CHI CONFERENCE ON HUMAN FACTORS IN COMPUTING SYSTEMS (CHI' 22), 2022,
  • [33] Step-length Estimation using Wrist-worn Accelerometer and GPS
    Kao, Wei-Wen
    Chen, Ching-Kun
    Lin, Jing-Shian
    PROCEEDINGS OF THE 24TH INTERNATIONAL TECHNICAL MEETING OF THE SATELLITE DIVISION OF THE INSTITUTE OF NAVIGATION (ION GNSS 2011), 2011, : 3274 - 3280
  • [34] Objective Assessment of Strength Training Exercises using a Wrist-Worn Accelerometer
    Conger, Scott A.
    Guo, Jun
    Fulkerson, Scott M.
    Pedigo, Lauren
    Chen, Hao
    Bassett, David R., Jr.
    MEDICINE & SCIENCE IN SPORTS & EXERCISE, 2016, 48 (09) : 1847 - 1855
  • [35] A Novel Method Of Assessing Dietary Behavior Using a Wrist-Worn Accelerometer
    Winfree, Kyle N.
    Dmitrieva, Natalia O.
    Behrens, Timothy K.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2017, 49 (05): : 14 - 14
  • [36] Levels of Activity Identification & Sleep Duration Detection with a Wrist-Worn Accelerometer-Based Device
    Verma, Vijay Kumar
    Lin, Wen-Yen
    Lee, Ming-Yih
    Lai, Chao-Sung
    2017 39TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2017, : 2369 - 2372
  • [37] Sleep Measurement Using Wrist-Worn Accelerometer Data Compared with Polysomnography
    Chase, John D.
    Busa, Michael A.
    Staudenmayer, John W.
    Sirard, John R.
    SENSORS, 2022, 22 (13)
  • [38] Estimating Sedentary Time from a Hip- and Wrist-Worn Accelerometer
    Marcotte, Robert T.
    Petrucci, Greg J.
    Cox, Melanna F.
    Freedson, Patty S.
    Staudenmayer, John W.
    Sirard, John R.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2020, 52 (01): : 225 - 232
  • [39] The Influence Of Wrist-worn Accelerometer Wear Location On Free-living Physical Activity In Adolescents
    Davila, Edward M.
    Heil, Daniel P.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2012, 44 : 491 - 492
  • [40] uLift: Adaptive Workout Tracker Using a Single Wrist-Worn Accelerometer
    Lim, Jongkuk
    Oh, Youngmin
    Choi, Younggeun
    IEEE ACCESS, 2024, 12 : 21710 - 21722