Compositional and beam-size-dependent effects on pressure baseline in clumped isotope mass spectrometry

被引:1
|
作者
Venturelli, Ryan A. [1 ]
Rosenheim, Brad E. [1 ]
机构
[1] Univ S Florida, Coll Marine Sci, 140 7th Ave South, St Petersburg, FL 33701 USA
关键词
MULTIPLY SUBSTITUTED ISOTOPOLOGUES; CARBONATE MINERALS; C-13-O-18; BONDS; REFERENCE FRAME; CO2; VARIABILITY; DELTA(47); CALIBRATION; CORAL; FRACTIONATION;
D O I
10.1002/rcm.8303
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Rationale The analysis of carbonate samples for the application of clumped isotopes to paleoclimate reconstruction necessitates smaller beam intensities. However, there is a relationship between beam intensity and pressure-dependent baseline (PBL), and therefore between beam intensity and the correction for PBL. Here we explain the relationship between PBL and beam intensity to develop a better correction protocol and an improved understanding of clumped isotope mass spectrometry. Methods We describe a beam size experiment using our Isoprime isotope ratio mass spectrometer in which samples of the carbonate standard IAEA-C1 were analyzed at 30, 50, and 70 nA to establish an optimal protocol and a new method to correct for PBL using the theoretical constraint of invariable Delta(47) over a range of delta(47) (bulk isotope composition) values. We also explore the effects of both over- and under-correction of PBL on equilibrated and heated gas samples to understand the effect of mis-correction of PBL. Results The results of our beam size experiments showed that a direct measurement of the baseline consistently introduced variability to measurements of the Delta(47) of heated gases, equilibrated gases, and carbonate standards. These results necessitated a new protocol to account for PBL in our system. Our new approach flattens the reference frame line slope to 0 and, importantly, reduces the variability of data points about the heated gas line. We also describe, for the first time, an empirically derived description of the compositional effect of PBL. Conclusions A seemingly small change in our isotope ratio mass spectrometer resulted in a better understanding of PBL, for which we have developed an empirically based correction protocol to apply. Our new protocol has the potential to reduce analytical time for laboratories measuring PBL, and supports the need for carbonate mineral-based clumped isotope standards.
引用
收藏
页码:140 / 148
页数:9
相关论文
共 50 条
  • [31] BORON IMPLANTATION IN SILICON - ISOTOPE EFFECTS STUDIED BY SECONDARY ION MASS-SPECTROMETRY
    SVENSSON, BG
    LINNROS, JT
    HOLMEN, G
    [J]. JOURNAL OF APPLIED PHYSICS, 1990, 68 (01) : 73 - 77
  • [32] Matrix effects in plutonium isotope ratio measurements using thermal ionization mass spectrometry
    Mathew, Kattathu Joseph
    Ottenfeld, Chelsea
    Levesque, Steven
    Keller, Russ
    [J]. JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2022, 331 (02) : 1005 - 1017
  • [33] Determination of kinetic isotope effects for nucleoside hydrolases using gas chromatography/mass spectrometry
    Kline, PC
    Rezaee, M
    Lee, TA
    [J]. ANALYTICAL BIOCHEMISTRY, 1999, 275 (01) : 6 - 10
  • [34] Adsorption in gas mass spectrometry II. Effects on the measurement of isotope amount ratios
    Gonfiantini, R
    Valkiers, S
    Taylor, PDP
    De Bievre, P
    [J]. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 1997, 171 (1-3) : 231 - 242
  • [35] Matrix effects in plutonium isotope ratio measurements using thermal ionization mass spectrometry
    Kattathu Joseph Mathew
    Chelsea Ottenfeld
    Steven Levesque
    Russ Keller
    [J]. Journal of Radioanalytical and Nuclear Chemistry, 2022, 331 : 1005 - 1017
  • [36] NON MASS-DEPENDENT CALCIUM ISOTOPE EFFECTS IN AND AMONG PLANETARY MATERIALS
    Simon, J. I.
    Armytage, R. M. G.
    Tappa, M. J.
    [J]. METEORITICS & PLANETARY SCIENCE, 2019, 54
  • [37] Mass spectrometry mapping and quantitation of stimulation-dependent phosphorylation of EGF receptor by stable isotope labeling
    Erba, E. Boeri
    Matthiesen, R.
    Bunkenborg, J.
    Schulze, W.
    Di Stefano, P.
    Defilippi, P.
    Norregaard, O. Jensen
    [J]. MOLECULAR & CELLULAR PROTEOMICS, 2005, 4 (08) : S274 - S274
  • [38] ISOTOPE-DILUTION LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY USING A PARTICLE-BEAM INTERFACE
    DOERGE, DR
    [J]. ANALYTICAL CHEMISTRY, 1993, 65 (10) : 1489 - 1490
  • [39] Isotope fractionation during ion beam formation in multi-collector inductively coupled plasma mass spectrometry
    Kivel, Niko
    Guenther-Leopold, Ines
    Vanhaecke, Frank
    Guenther, Detlef
    [J]. SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2012, 76 : 126 - 132
  • [40] Size selective effects in ion clusters probed via tandem mass spectrometry
    Garvey, James F.
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2005, 230 : U2847 - U2847