Adsorption in gas mass spectrometry II. Effects on the measurement of isotope amount ratios

被引:18
|
作者
Gonfiantini, R [1 ]
Valkiers, S [1 ]
Taylor, PDP [1 ]
De Bievre, P [1 ]
机构
[1] Commiss European Communities, Joint Res Ctr, Inst Reference Mat & Measurements, B-2440 Geel, Belgium
关键词
adsorption-desorption; adsorption isotopic effects; gas mass spectrometry; isotope amount ratios; leak rate; silicon tetrafluoride;
D O I
10.1016/S0168-1176(97)00129-8
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
Gas adsorption in the mass spectrometer inlet system (equipped with molecular leak) causes a deviation from linearity of the measured InRi/l data versus time, which affects the extrapolation to time t = 0 required to obtain the isotope amount ratios of a sample. The model first presented in (R. Gonfiantini, S. Valkiers, P.D.P. Taylor, P. De Bievre, Adsorption in gas mass spectrometry. I. Effects on the measurement of individual isotopic species, Int. J. Mass Spectrom. Ion Proc. (1997) in press) is further developed in order to show the effects of adsorption on the data obtained in long measurements of SiF4 samples and improve the extrapolation of InRi/l values to t = 0. The model enables to estimate the isotope fractionation factors for the processes of gas effusion through the molecular leak, and for adsorption and desorption on the inlet system walls. The fractionation factors obtained for gas effusion and adsorption are close to the expected value of (M-l/M-i)(1/2), where M-l and M-i are the molar masses of the isotopic species considered. The isotope fractionation factor for desorption, which can be evaluated only indirectly from the data fitting, indicates that the heavy isotopes are preferentially retained in the adsorbate. Model extrapolation of data obtained during the first 10 hours of measurement gives values of R-i/l(0) which are slightly but significantly smaller than those given by linear extrapolation of the first two hour data. The difference is, in relative terms, -(1.88 +/- 0.23) x 10(-4) for the Si-29/Si-28 ratio and -(3.25 +/- 0.47) x 10(-4) for the Si-30/Si-28 ratio. The resulting molar mass for silicon is (1.0 +/- 0.1) x 10(-6) parts lower than that obtained with the isotope amount ratios of the linear extrapolation. This effect is not negligible but it cancels by using synthetic isotope mixtures for the measurement calibration. The model does not match the data after 15 h of measurement. This may imply that more than one adsorption mode occurs. Effects related to molecule fragmentation and the space charge distribution in the ion source are discussed. (C) 1997 Elsevier Science B.V.
引用
收藏
页码:231 / 242
页数:12
相关论文
共 50 条
  • [1] Accurate Measurement of Isotope Amount Ratios of Lead in Bronze with Multicollector Inductively Coupled Plasma Mass Spectrometry
    Lee, Kyoung-Seok
    Kim, Jin-il
    Yim, Yong-Hyeon
    Hwang, Euijin
    Kim, Tae Kyu
    [J]. MASS SPECTROMETRY LETTERS, 2013, 4 (04) : 87 - 90
  • [2] Measurement of platinum isotope amount ratios by negative thermal ionization mass spectrometry using a thermionic quadrupole mass spectrometer
    Briche, CSJ
    Taylor, PDP
    DeBievre, P
    [J]. ANALYTICAL CHEMISTRY, 1997, 69 (04) : 791 - 793
  • [3] Absolute measurements of isotope amount ratios on gases Part II.: Application of the measurement models developed on real gases
    Valkiers, S.
    Varlam, M.
    Berglund, M.
    Taylor, P.
    Gonfiantini, R.
    De Bievre, P.
    [J]. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2008, 269 (1-2) : 71 - 77
  • [4] Measurement of Tin Isotope Ratios by Laser Resonance Ionization Mass Spectrometry
    Xie Yue
    Zhou Cheng
    Tu Cong
    Zhang Zu-Liang
    Wang Jian-Fei
    [J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2017, 45 (03) : 363 - 368
  • [5] High precision measurement of titanium isotope ratios by plasma source mass spectrometry
    Zhu, XK
    Makishima, A
    Guo, Y
    Belshaw, NS
    O'Nions, RK
    [J]. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2002, 220 (01) : 21 - 29
  • [6] MEASUREMENT OF ISOTOPE RATIOS IN SOLIDS BY GLOW-DISCHARGE MASS-SPECTROMETRY
    ECKER, KH
    PRITZKOW, W
    [J]. FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1994, 349 (1-3): : 207 - 208
  • [7] Is measurement of Si isotope ratios by inductively coupled plasma mass spectrometry realistic?
    Linge, K. L.
    Jarvis, K. E.
    [J]. GEOCHIMICA ET COSMOCHIMICA ACTA, 2006, 70 (18) : A361 - A361
  • [8] Capabilities of inductively coupled plasma mass spectrometry for the measurement of Fe isotope ratios
    Vanhaecke, F
    Balcaen, L
    De Wannemacker, G
    Moens, L
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2002, 17 (08) : 933 - 943
  • [9] SOME INSTRUMENTAL EFFECTS IN THE DETERMINATION OF STABLE CARBON ISOTOPE RATIOS BY GAS-CHROMATOGRAPHY ISOTOPE RATIO MASS-SPECTROMETRY
    EAKIN, PA
    FALLICK, AE
    GERC, J
    [J]. CHEMICAL GEOLOGY, 1992, 101 (1-2) : 71 - 79
  • [10] Adsorption in gas mass spectrometry .1. Effects on the measurement of individual isotopic species
    Gonfiantini, R
    Valkiers, S
    Taylor, PDP
    DeBievre, P
    [J]. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1997, 163 (03): : 207 - 219