Compositional and beam-size-dependent effects on pressure baseline in clumped isotope mass spectrometry

被引:1
|
作者
Venturelli, Ryan A. [1 ]
Rosenheim, Brad E. [1 ]
机构
[1] Univ S Florida, Coll Marine Sci, 140 7th Ave South, St Petersburg, FL 33701 USA
关键词
MULTIPLY SUBSTITUTED ISOTOPOLOGUES; CARBONATE MINERALS; C-13-O-18; BONDS; REFERENCE FRAME; CO2; VARIABILITY; DELTA(47); CALIBRATION; CORAL; FRACTIONATION;
D O I
10.1002/rcm.8303
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Rationale The analysis of carbonate samples for the application of clumped isotopes to paleoclimate reconstruction necessitates smaller beam intensities. However, there is a relationship between beam intensity and pressure-dependent baseline (PBL), and therefore between beam intensity and the correction for PBL. Here we explain the relationship between PBL and beam intensity to develop a better correction protocol and an improved understanding of clumped isotope mass spectrometry. Methods We describe a beam size experiment using our Isoprime isotope ratio mass spectrometer in which samples of the carbonate standard IAEA-C1 were analyzed at 30, 50, and 70 nA to establish an optimal protocol and a new method to correct for PBL using the theoretical constraint of invariable Delta(47) over a range of delta(47) (bulk isotope composition) values. We also explore the effects of both over- and under-correction of PBL on equilibrated and heated gas samples to understand the effect of mis-correction of PBL. Results The results of our beam size experiments showed that a direct measurement of the baseline consistently introduced variability to measurements of the Delta(47) of heated gases, equilibrated gases, and carbonate standards. These results necessitated a new protocol to account for PBL in our system. Our new approach flattens the reference frame line slope to 0 and, importantly, reduces the variability of data points about the heated gas line. We also describe, for the first time, an empirically derived description of the compositional effect of PBL. Conclusions A seemingly small change in our isotope ratio mass spectrometer resulted in a better understanding of PBL, for which we have developed an empirically based correction protocol to apply. Our new protocol has the potential to reduce analytical time for laboratories measuring PBL, and supports the need for carbonate mineral-based clumped isotope standards.
引用
收藏
页码:140 / 148
页数:9
相关论文
共 50 条
  • [1] Background effects on Faraday collectors in gas-source mass spectrometry and implications for clumped isotope measurements
    Bernasconi, Stefano M.
    Hu, Bin
    Wacker, Ulrike
    Fiebig, Jens
    Breitenbach, Sebastian F. M.
    Rutz, Tanja
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2013, 27 (05) : 603 - 612
  • [2] Methods and limitations of 'clumped' CO2 isotope (Δ47) analysis by gas-source isotope ratio mass spectrometry
    Huntington, K. W.
    Eiler, J. M.
    Affek, H. P.
    Guo, W.
    Bonifacie, M.
    Yeung, L. Y.
    Thiagarajan, N.
    Passey, B.
    Tripati, A.
    Daeron, M.
    Came, R.
    [J]. JOURNAL OF MASS SPECTROMETRY, 2009, 44 (09): : 1318 - 1329
  • [3] Memory effects in combining isotope ratio monitoring with isotope dilution mass spectrometry
    Dube, G
    Henrion, A
    Ohlendorf, R
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1999, 13 (12) : 1186 - 1188
  • [4] Choice of 17O correction affects clumped isotope (Δ47) values of CO2 measured with mass spectrometry
    Schauer, Andrew J.
    Kelson, Julia
    Saenger, Casey
    Huntington, Katharine W.
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2016, 30 (24) : 2607 - 2616
  • [5] Considerations for uranium isotope ratio analysis by atmospheric pressure ionization mass spectrometry
    Forbes, Thomas P.
    Szakal, Christopher
    [J]. ANALYST, 2019, 144 (01) : 317 - 323
  • [6] Atmospheric pressure plasma analysis by modulated molecular beam mass spectrometry
    Gonzalvo, YA
    Whitmore, TD
    Rees, JA
    Seymour, DL
    Stoffels, E
    [J]. JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A, 2006, 24 (03): : 550 - 553
  • [7] Probing the unusual isotope effects in ozone formation: Bath gas and pressure dependence of the non-mass-dependent isotope enrichments in ozone
    Feilberg, K. L.
    Wiegel, A. A.
    Boering, K. A.
    [J]. CHEMICAL PHYSICS LETTERS, 2013, 556 : 1 - 8
  • [8] CHLORINE ISOTOPE EFFECTS IN MASS-SPECTROMETRY BY MULTIPLE REACTION MONITORING
    ZAKETT, D
    FLYNN, RGA
    COOKS, RG
    [J]. JOURNAL OF PHYSICAL CHEMISTRY, 1978, 82 (22): : 2359 - 2362
  • [9] A modified procedure for gas-source isotope ratio mass spectrometry: the long-integration dual-inlet (LIDI) methodology and implications for clumped isotope measurements
    Hu, Bin
    Radke, Jens
    Schlueter, Hans-Juergen
    Heine, Frank Torsten
    Zhou, Liping
    Bernasconi, Stefano M.
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2014, 28 (13) : 1413 - 1425
  • [10] A pyrolysis mass spectrometry study of temperature-dependent compositional shifts in Xanthomonas (Pseudomonas) maltophilia
    Magee, JT
    Hindmarch, JM
    Winstanley, TG
    [J]. ZENTRALBLATT FUR BAKTERIOLOGIE-INTERNATIONAL JOURNAL OF MEDICAL MICROBIOLOGY VIROLOGY PARASITOLOGY AND INFECTIOUS DISEASES, 1997, 285 (02): : 299 - 304