Memory effects in combining isotope ratio monitoring with isotope dilution mass spectrometry

被引:0
|
作者
Dube, G [1 ]
Henrion, A [1 ]
Ohlendorf, R [1 ]
机构
[1] Phys Tech Bundesanstalt, D-38116 Braunschweig, Germany
关键词
D O I
10.1002/(SICI)1097-0231(19990630)13:12<1186::AID-RCM635>3.0.CO;2-8
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Combining isotope ratio monitoring with isotope dilution techniques provides very accurate results in the quantitative analysis of volatile organic chemical compounds by gas chromatography/mass spectrometry (GC/MS). However, this method requires that spikes highly enriched in C-13 be used. This may lead to memory effects which will be investigated in more detail. They occur when the component of the mixture to be investigated exhibits an isotope ratio which is different from that of the component eluted earlier from the column during the chromatographic separation process. A residue of this component, which is shown in the gas chromatogram as tailing, falsifies the result of the isotope ratio measurement. This also leads to false amount-of-substance measurement results. Memory effects can be avoided by using spikes of low C-13 content, by adjusting the composition of the reference solution to that of the sample, or by ensuring effective sample preparation, thus separating disturbing mixture components prior to the measurement. Copyright (C) 1999 John Whey & Sons, Ltd.
引用
收藏
页码:1186 / 1188
页数:3
相关论文
共 50 条
  • [1] Application of the combination of isotope ratio monitoring with isotope dilution mass spectrometry to the determination of glucose in serum
    Dube, G
    Henrion, A
    Ohlendorf, R
    Vidal, C
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2001, 15 (15) : 1322 - 1326
  • [2] Isotope ratio monitoring gas chromatography mass spectrometry of D H by high temperature conversion isotope ratio mass spectrometry
    Hilkert, AW
    Douthitt, CB
    Schlüter, HJ
    Brand, WA
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1999, 13 (13) : 1226 - 1230
  • [3] Combining isotope ratio monitoring with isotope dilution techniques for high accuracy quantification in organic chemical analysis
    Dube, G
    Henrion, A
    Ohlendorf, R
    Richter, W
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1998, 12 (01) : 28 - 32
  • [4] Combining Isotope Ratio Monitoring with Isotope Dilution Techniques for High Accuracy Quantification in Organic Chemical Analysis
    Dube, G.
    Henrion, A.
    Ohlendorf, R.
    Richter, W.
    [J]. Rapid Communications in Mass Spectrometry, 12 (01):
  • [5] Isotope ratio mass spectrometry
    Muccio, Zeland
    Jackson, Glen P.
    [J]. ANALYST, 2009, 134 (02) : 213 - 222
  • [6] Isotope ratio monitoring of small molecules and macromolecules by liquid chromatography coupled to isotope ratio mass spectrometry
    Godin, JP
    Hau, J
    Fay, LB
    Hopfgartner, G
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2005, 19 (18) : 2689 - 2698
  • [7] High precision isotope ratio monitoring techniques in mass spectrometry
    Brand, WA
    [J]. JOURNAL OF MASS SPECTROMETRY, 1996, 31 (03): : 225 - 235
  • [8] Carbon and nitrogen determinations using an isotope dilution ratio mass spectrometry approach
    Carkeet, C
    Dueker, SR
    Follett, JR
    Correa, TE
    Clifford, AJ
    [J]. FASEB JOURNAL, 2001, 15 (04): : A260 - A260
  • [9] Detection limit of isotope dilution mass spectrometry
    Yu, LL
    Fassett, JD
    Guthrie, WF
    [J]. ANALYTICAL CHEMISTRY, 2002, 74 (15) : 3887 - 3891
  • [10] ISOTOPE-DILUTION MASS-SPECTROMETRY
    HEUMANN, KG
    [J]. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1992, 118 : 575 - 592