The RespiCon (TM) sampler is a multistage virtual impactor that simultaneously collects the ISO/CEN/ACGIH size fractions of inhalable, thoracic, and respirable particulate matter. The field performance of the device for measurement of industrial wood processing dust was evaluated against reference size-selective samplers: the IOM sampler (inhalable dust), the GK 2.69 cyclone (thoracic dust), and the SKC aluminum cyclone (respirable dust). Seventy-one sets of area samples were collected from 10 wood processing plants, with the samplers mounted either in the free-field or on a two-dimensional "bluff body." The geometric mean (range) dust levels across all plants measured by the reference samplers were: inhalable, 1.35 mg/ m 3 (0.11-11.06); thoracic, 0.31 mg/m(3) (0.05-1.38); and respirable, 0.10 mg/m(3) (0.02-0.54). In comparing the RespiCon with the reference samplers, there was no significant difference between sampling in the free-field versus bluff-body modes. For inhalable dust, there was no significant difference between the RespiCon and the IOM sampler after applying a correction factor of 1.5x to the extrathoracic data obtained from the RespiCon. Without the correction factor the RespiCon under-sample inhalable dust by an average of 23%. For thoracic dust, the RespiCon was shown to oversample the extrathoracic dust fraction resulting in an overall error of 48%. A simple correction based on the inhalable and thoracic dust levels reported by the RespiCon is proposed. For respirable dust, there was a significant difference between the RespiCon and the SKC cyclone, but the data were equivocal due to imprecision in measurement of the low respirable dust concentrations encountered and the likelihood of bias in the reference sampler. Overall, the RespiCon sampler appears to be a suitable size-selective sampling device for industrial wood processing dust, although adjustments should be made to the inhalable and thoracic dust results.
引用
收藏
页码:219 / 226
页数:8
相关论文
共 50 条
  • [41] Evaluation of procedures to reduce bias in fish growth parameter estimates resulting from size-selective sampling
    Gwinn, Daniel C.
    Allen, Micheal S.
    Rogers, Mark W.
    FISHERIES RESEARCH, 2010, 105 (02) : 75 - 79
  • [42] A field comparison of inhalable and thoracic size selective sampling techniques
    Davies, HW
    Teschke, K
    Demers, PA
    ANNALS OF OCCUPATIONAL HYGIENE, 1999, 43 (06): : 381 - 392
  • [43] Respirable size-selective sampler for end-of-shift quartz measurement: Development and performance
    Lee, Taekhee
    Lee, Larry
    Cauda, Emanuele
    Hummer, Jon
    Harper, Martin
    JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2017, 14 (05) : 335 - 342
  • [44] Wood Dust Sampling: Field Evaluation of Personal Samplers When Large Particles Are Present
    Lee, Taekhee
    Harper, Martin
    Slaven, James E.
    Lee, Kiyoung
    Rando, Roy J.
    Maples, Elizabeth H.
    ANNALS OF OCCUPATIONAL HYGIENE, 2011, 55 (02): : 180 - 191
  • [45] A SIZE-SELECTIVE DUST SAMPLER WHICH CONFORMS TO LUNG MODEL PROPOSED BY ICRP TASK GROUP ON LUNG DYNAMICS
    STEPHENS.J
    HEALTH PHYSICS, 1970, 19 (01): : 68 - +
  • [46] Influence of Suspending Liquid, Impactor Type, and Substrate on Size-Selective Sampling of MS2 and Adenovirus Aerosols
    Appert, Jessica
    Raynor, Peter C.
    Abin, Martha
    Chander, Yogesh
    Guarino, Helena
    Goyal, Sagar M.
    Zuo, Zhili
    Ge, Song
    Kuehn, Thomas H.
    AEROSOL SCIENCE AND TECHNOLOGY, 2012, 46 (03) : 249 - 257
  • [47] Evaluation of Pump Pulsation in Respirable Size-Selective Sampling: Part III. Investigation of European Standard Methods
    Soo, Jhy-Charm
    Lee, Eun Gyung
    Lee, Larry A.
    Kashon, Michael L.
    Harper, Martin
    ANNALS OF OCCUPATIONAL HYGIENE, 2014, 58 (08): : 1006 - 1017
  • [48] Size-selective downstream processing of virus particles and non-enveloped virus-like particles
    Hillebrandt, Nils
    Hubbuch, Juergen
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2023, 11
  • [49] FIELD PERFORMANCE OF A NEW DESIGN OF A TOTAL INHALABLE DUST SAMPLING HEAD
    MARLEY, KA
    ANNALS OF OCCUPATIONAL HYGIENE, 1994, 38 (06): : 895 - 902
  • [50] Fabrication of Ni nanoparticles and their size-selective self-assembly into chains under external magnetic field
    Singamaneni, S
    Bliznyuk, V
    APPLIED PHYSICS LETTERS, 2005, 87 (16) : 1 - 3