Field performance of the RespiCon™ for size-selective sampling of industrial wood processing dust

被引:19
|
作者
Rando, R
Poovey, H
Mokadam, D
Brisolara, J
Glindmeyer, H
机构
[1] Tulane Univ, Sch Publ Hlth & Trop Med, Dept Environm Sci, New Orleans, LA 70112 USA
[2] Tulane Univ, Sch Med, Sect Pulm Dis & Environm Med, New Orleans, LA 70118 USA
关键词
IOM sampler; RespiCon; size-selective sampling; wood dust;
D O I
10.1080/15459620590930309
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The RespiCon (TM) sampler is a multistage virtual impactor that simultaneously collects the ISO/CEN/ACGIH size fractions of inhalable, thoracic, and respirable particulate matter. The field performance of the device for measurement of industrial wood processing dust was evaluated against reference size-selective samplers: the IOM sampler (inhalable dust), the GK 2.69 cyclone (thoracic dust), and the SKC aluminum cyclone (respirable dust). Seventy-one sets of area samples were collected from 10 wood processing plants, with the samplers mounted either in the free-field or on a two-dimensional "bluff body." The geometric mean (range) dust levels across all plants measured by the reference samplers were: inhalable, 1.35 mg/ m 3 (0.11-11.06); thoracic, 0.31 mg/m(3) (0.05-1.38); and respirable, 0.10 mg/m(3) (0.02-0.54). In comparing the RespiCon with the reference samplers, there was no significant difference between sampling in the free-field versus bluff-body modes. For inhalable dust, there was no significant difference between the RespiCon and the IOM sampler after applying a correction factor of 1.5x to the extrathoracic data obtained from the RespiCon. Without the correction factor the RespiCon under-sample inhalable dust by an average of 23%. For thoracic dust, the RespiCon was shown to oversample the extrathoracic dust fraction resulting in an overall error of 48%. A simple correction based on the inhalable and thoracic dust levels reported by the RespiCon is proposed. For respirable dust, there was a significant difference between the RespiCon and the SKC cyclone, but the data were equivocal due to imprecision in measurement of the low respirable dust concentrations encountered and the likelihood of bias in the reference sampler. Overall, the RespiCon sampler appears to be a suitable size-selective sampling device for industrial wood processing dust, although adjustments should be made to the inhalable and thoracic dust results.
引用
收藏
页码:219 / 226
页数:8
相关论文
共 50 条
  • [21] DEVELOPMENT OF IMPACTOR SIZE-SELECTIVE DUST SAMPLERS AT THE ELLIOT-LAKE-LABORATORY
    KNIGHT, G
    AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1991, 52 (04): : 164 - 171
  • [22] Processing-Structure-Performance Relationships of Microporous Metal-Organic Polymers for Size-Selective Separations
    Huang, Jen-Yu
    Xu, Yuanze
    Milner, Phillip J.
    Hanrath, Tobias
    ACS APPLIED MATERIALS & INTERFACES, 2021, 13 (03) : 3521 - 3527
  • [24] High-volume sampler for size-selective sampling of bioaerosols including viruses
    Lim, Jun-Hyung
    Nam, Sang Hwan
    Kim, Jongwoo
    Kim, Nam Hoon
    Park, Gun-Soo
    Maeng, Jin-Soo
    Yook, Se-Jin
    ATMOSPHERIC ENVIRONMENT, 2021, 265
  • [25] Development of a single cyclone separator with three stages for size-selective sampling of particles
    Park, Chun-Woo
    Song, Dae-Hyun
    Yook, Se-Jin
    JOURNAL OF AEROSOL SCIENCE, 2015, 89 : 18 - 25
  • [26] Evaluation of Pump Pulsation in Respirable Size-Selective Sampling: Part II. Changes in Sampling Efficiency
    Lee, Eun Gyung
    Lee, Taekhee
    Kim, Seung Won
    Lee, Larry
    Flemmer, Michael M.
    Harper, Martin
    ANNALS OF OCCUPATIONAL HYGIENE, 2014, 58 (01): : 74 - 84
  • [27] Size-selective accretion of dust on to CPDs: low CPD masses and filtration of larger grains
    Karlin, Samuel M.
    Panic, Olja
    van Loo, Sven
    MONTHLY NOTICES OF THE ROYAL ASTRONOMICAL SOCIETY, 2023, 520 (01) : 1258 - 1270
  • [28] The dust holding capacity of porous plastic foam used in particle size-selective smapling
    Breum, N.O., 1600, Elsevier Science Ltd, Exeter (31):
  • [29] A TECHNIQUE FOR ASSESSING SIZE-SELECTIVE DUST SAMPLERS USING THE APS AND POLYDISPERSE TEST AEROSOLS
    KENNY, LC
    LIDEN, G
    JOURNAL OF AEROSOL SCIENCE, 1991, 22 (01) : 91 - 100
  • [30] EFFECTS OF SIZE-SELECTIVE MORTALITY AND SAMPLING BIAS ON ESTIMATES OF GROWTH MORTALITY PRODUCTION AND YIELD
    RICKER, WE
    JOURNAL OF THE FISHERIES RESEARCH BOARD OF CANADA, 1969, 26 (03): : 479 - &