Field performance of the RespiCon™ for size-selective sampling of industrial wood processing dust

被引:19
|
作者
Rando, R
Poovey, H
Mokadam, D
Brisolara, J
Glindmeyer, H
机构
[1] Tulane Univ, Sch Publ Hlth & Trop Med, Dept Environm Sci, New Orleans, LA 70112 USA
[2] Tulane Univ, Sch Med, Sect Pulm Dis & Environm Med, New Orleans, LA 70118 USA
关键词
IOM sampler; RespiCon; size-selective sampling; wood dust;
D O I
10.1080/15459620590930309
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The RespiCon (TM) sampler is a multistage virtual impactor that simultaneously collects the ISO/CEN/ACGIH size fractions of inhalable, thoracic, and respirable particulate matter. The field performance of the device for measurement of industrial wood processing dust was evaluated against reference size-selective samplers: the IOM sampler (inhalable dust), the GK 2.69 cyclone (thoracic dust), and the SKC aluminum cyclone (respirable dust). Seventy-one sets of area samples were collected from 10 wood processing plants, with the samplers mounted either in the free-field or on a two-dimensional "bluff body." The geometric mean (range) dust levels across all plants measured by the reference samplers were: inhalable, 1.35 mg/ m 3 (0.11-11.06); thoracic, 0.31 mg/m(3) (0.05-1.38); and respirable, 0.10 mg/m(3) (0.02-0.54). In comparing the RespiCon with the reference samplers, there was no significant difference between sampling in the free-field versus bluff-body modes. For inhalable dust, there was no significant difference between the RespiCon and the IOM sampler after applying a correction factor of 1.5x to the extrathoracic data obtained from the RespiCon. Without the correction factor the RespiCon under-sample inhalable dust by an average of 23%. For thoracic dust, the RespiCon was shown to oversample the extrathoracic dust fraction resulting in an overall error of 48%. A simple correction based on the inhalable and thoracic dust levels reported by the RespiCon is proposed. For respirable dust, there was a significant difference between the RespiCon and the SKC cyclone, but the data were equivocal due to imprecision in measurement of the low respirable dust concentrations encountered and the likelihood of bias in the reference sampler. Overall, the RespiCon sampler appears to be a suitable size-selective sampling device for industrial wood processing dust, although adjustments should be made to the inhalable and thoracic dust results.
引用
收藏
页码:219 / 226
页数:8
相关论文
共 50 条
  • [1] The dust holding capacity of porous plastic foam used in particle size-selective sampling
    Breum, NO
    JOURNAL OF AEROSOL SCIENCE, 2000, 31 (03) : 379 - 385
  • [2] A REFERENCE SIZE-SELECTIVE SAMPLER FOR RESPIRABLE DUST
    KNIGHT, G
    AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1988, 49 (05): : 248 - 254
  • [3] SIZE-SELECTIVE GRAVIMETRIC SAMPLING IN DUSTY INDUSTRIES
    AYER, HE
    SUTTON, GW
    DAVIS, IH
    AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1968, 29 (04): : 336 - &
  • [4] A CYCLONE FOR SIZE-SELECTIVE SAMPLING OF AMBIENT AIR
    JOHN, W
    REISCHL, G
    JOURNAL OF THE AIR POLLUTION CONTROL ASSOCIATION, 1980, 30 (08): : 872 - 876
  • [5] SIZE-SELECTIVE SAMPLING OF PLUTONIUM AND URANIUM AEROSOLS
    FERRAN, GH
    HYATT, EC
    AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1969, 30 (02): : 113 - &
  • [6] RATIONALE OF ACGIH RECOMMENDATIONS FOR SIZE-SELECTIVE SAMPLING
    SODERHOLM, SC
    ANNALS OF OCCUPATIONAL HYGIENE, 1986, 30 (04): : 518 - 520
  • [7] SIZE-SELECTIVE SAMPLING OF PLUTONIUM AND URANIUM AEROSOLS
    FERRAN, GH
    HYATT, EC
    AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1970, 31 (03): : 282 - &
  • [8] Laboratory and field testing of particle size-selective sampling methods for mineral dusts
    Teikari, M
    Linnainmaa, M
    Laitinen, J
    Kalliokoski, P
    Vincent, J
    Tiita, P
    Raunemaa, T
    AIHA JOURNAL, 2003, 64 (03): : 312 - 318
  • [9] Size-selective sampling of particulates using a physiologic sampling pump
    Lee, Larry A.
    Lee, Eun Gyung
    Lee, Taekhee
    Kim, Seung Won
    Slaven, James E.
    Harper, Martin
    JOURNAL OF ENVIRONMENTAL MONITORING, 2011, 13 (03): : 527 - 535
  • [10] PROPOSED INTERNATIONAL CONVENTIONS FOR PARTICLE SIZE-SELECTIVE SAMPLING
    SODERHOLM, SC
    ANNALS OF OCCUPATIONAL HYGIENE, 1989, 33 (03): : 301 - 320