Determination of arsenic and cadmium in crude oil by direct sampling graphite furnace atomic absorption spectrometry

被引:26
|
作者
de Jesus, Alexandre [1 ]
Zmozinski, Ariane Vanessa [1 ]
Ferreira Damin, Isabel Cristina [2 ]
Silva, Marcia Messias [1 ,3 ]
Rodrigues Vale, Maria Goreti [1 ,3 ]
机构
[1] Univ Fed Rio Grande do Sul, Inst Quim, BR-91501970 Porto Alegre, RS, Brazil
[2] Fac Dom Bosco Porto Alegre, BR-90520280 Porto Alegre, RS, Brazil
[3] Univ Fed Bahia, Inst Natl Ciencia & Tecnol CNPq, INCT Energia & Ambiente, BR-40170115 Salvador, BA, Brazil
关键词
Arsenic; Cadmium; Direct sampling; Graphite furnace atomic absorption spectrometry; PETROLEUM; VANADIUM; METALS; COPPER; NICKEL; LEAD; STABILIZATION; NAPHTHA; FILTER;
D O I
10.1016/j.sab.2012.03.010
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
In this work, a direct sampling graphite furnace atomic absorption spectrometry method has been developed for the determination of arsenic and cadmium in crude oil samples. The samples were weighed directly on the solid sampling platforms and introduced into the graphite tube for analysis. The chemical modifier used for both analytes was a mixture of 0.1% Pd + 0.06% Mg + 0.06% Triton X-100. Pyrolysis and atomization curves were obtained for both analytes using standards and samples. Calibration curves with aqueous standards could be used for both analytes. The limits of detection obtained were 5.1 mu g kg(-1) for arsenic and 0.2 mu g kg(-1) for cadmium, calculated for the maximum amount of sample that can be analyzed (8 mg and 10 mg) for arsenic and cadmium, respectively. Relative standard deviations lower than 20% were obtained. For validation purposes, a calibration curve was constructed with the SRM 1634c and aqueous standards for arsenic and the results obtained for several crude oil samples were in agreement according to paired t-test. The result obtained for the determination of arsenic in the SRM against aqueous standards was also in agreement with the certificate value. As there is no crude oil or similar reference material available with a certified value for cadmium, a digestion in an open vessel under reflux using a "cold finger" was adopted for validation purposes. The use of paired t-test showed that the results obtained by direct sampling and digestion were in agreement at a 95% confidence level. Recovery tests were carried out with inorganic and organic standards and the results were between 88% and 109%. The proposed method is simple, fast and reliable, being appropriated for routine analysis. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:86 / 91
页数:6
相关论文
共 50 条
  • [41] Determination of cadmium in marine sediment by graphite furnace atomic absorption spectrometry using a slurry sampling with ultrasonic agitation
    Cheng, Xiang-Sheng
    Xu, Ren
    Su, Yao-Dong
    Zhang, Bing-Ru
    Ni, Ya-Ming
    Kao Teng Hsueh Hsiao Hua Heush Hsueh Pao/ Chemical Journal of Chinese Universities, 1999, 20 (5 Suppl):
  • [42] Determination of cadmium, copper and lead in mineral coal using solid sampling graphite furnace atomic absorption spectrometry
    Vale, MGR
    Silva, MM
    Welz, B
    Lima, ÉC
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2001, 56 (10) : 1859 - 1873
  • [43] Method for cadmium and lead longitudinal profiles determination in hair by solid sampling graphite furnace atomic absorption spectrometry
    Nomura, Cassiana Seimi
    Oliveira, Pedro Vitoriano
    ANALYTICAL METHODS, 2010, 2 (01) : 49 - 53
  • [44] Slurry sampling for the determination of arsenic, cadmium, and lead in mainstream cigarette smoke condensate by graphite furnace–atomic absorption spectrometry and inductively coupled plasma–mass spectrometry
    K. Torrence
    R. McDaniel
    D. Self
    M. Chang
    Analytical and Bioanalytical Chemistry, 2002, 372 : 723 - 731
  • [45] THE DETERMINATION OF ARSENIC BY ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY WITH A GRAPHITE-FURNACE .1. DIFFICULTIES IN THE DIRECT DETERMINATION
    CHAKRABORTI, D
    DEJONGHE, W
    ADAMS, F
    ANALYTICA CHIMICA ACTA, 1980, 119 (02) : 331 - 340
  • [46] Multivariate optimization for the determination of cadmium and lead in crude palm oil by graphite furnace atomic absorption spectrometry after extraction induced by emulsion breaking
    Valasques, Gisseli S.
    dos Santos, Ana Maria P.
    de Souza, Valdinei S.
    Teixeira, Leonardo S. G.
    Alves, Juscelia P. S.
    Santos, Mirela de Jesus
    dos Santos, Wagna P. C.
    Bezerra, Marcos A.
    MICROCHEMICAL JOURNAL, 2020, 153
  • [47] Development of methods for the determination of cadmium and thallium in oil shale by-products with graphite furnace atomic absorption spectrometry using direct analysis
    Oliveira, Helen R.
    Mesko, Marcia F.
    Vale, Maria Goreti R.
    Silveira, Carlos Augusto P.
    Picoloto, Rochele S.
    Becker, Emilene M.
    MICROCHEMICAL JOURNAL, 2014, 116 : 55 - 61
  • [48] DIRECT DETERMINATION OF CADMIUM IN DRINKING-WATER SUPPLIES BY GRAPHITE-FURNACE ATOMIC-ABSORPTION SPECTROMETRY
    MERANGER, JC
    SUBRAMANIAN, KS
    CANADIAN JOURNAL OF SPECTROSCOPY, 1979, 24 (05): : 132 - 137
  • [49] DETERMINATION OF ARSENIC, CADMIUM, LEAD AND SELENIUM IN HIGHLY MINERALIZED WATERS BY GRAPHITE-FURNACE ATOMIC-ABSORPTION SPECTROMETRY
    BOZSAI, G
    SCHLEMMER, G
    GROBENSKI, Z
    TALANTA, 1990, 37 (06) : 545 - 553