Novel Computerized Method for Automated Determination of Ventilatory Threshold and Respiratory Compensation Point

被引:8
|
作者
Kim, Kyoung Jae [1 ]
Rivas, Eric [1 ]
Prejean, Brian [1 ]
Frisco, Dillon [2 ]
Young, Millennia [3 ]
Downs, Meghan [3 ]
机构
[1] KBR, Houston, TX 77002 USA
[2] JES Technol, Houston, TX USA
[3] NASA, Johnson Space Ctr, Houston, TX USA
基金
美国国家航空航天局;
关键词
incremental exercise; noninvasive measurement; ventilatory threshold; respiratory compensation point; automated determination; ANAEROBIC THRESHOLD; GAS-EXCHANGE; GENDER-DIFFERENCES; EXERCISE; LACTATE; ADAPTATION; DETECT; POWER; SEX;
D O I
10.3389/fphys.2021.782167
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Introduction: The ventilatory threshold (named as VT1) and the respiratory compensation point (named as VT2) describe prominent changes of metabolic demand and exercise intensity domains during an incremental exercise test.Methods: A novel computerized method based on the optimization method was developed for automatically determining VT1 and VT2 from expired air during a progressive maximal exercise test. A total of 109 peak cycle tests were performed by members of the US astronaut corps (74 males and 35 females). We compared the automatically determined VT1 and VT2 values against the visual subjective and independent analyses of three trained evaluators. We also characterized VT1 and VT2 and the respective absolute and relative work rates and distinguished differences between sexes.Results: The automated compared to the visual subjective values were analyzed for differences with t test, for agreement with Bland-Altman plots, and for equivalence with a two one-sided test approach. The results showed that the automated and visual subjective methods were statistically equivalent, and the proposed approach reliably determined VT1 and VT2 values. Females had lower absolute O-2 uptake, work rate, and ventilation, and relative O-2 uptake at VT1 and VT2 compared to men (p <= 0.04). VT1 and VT2 occurred at a greater relative percentage of their peak VO2 for females (67 and 88%) compared to males (55 and 74%; main effect for sex: p < 0.001). Overall, VT1 occurred at 58% of peak VO2, and VT2 occurred at 79% of peak VO2 (p < 0.0001).Conclusion: Improvements in determining of VT1 and VT2 by automated analysis are time efficient, valid, and comparable to subjective visual analysis and may provide valuable information in research and clinical practice as well as identifying exercise intensity domains of crewmembers in space.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Characterization of the Performance of a Novel, Easily Automated Total Nucleic Acid Isolation Method for Respiratory Specimens
    Jost, M.
    Nelson, L.
    Mytton, S.
    Tuggle, T.
    Douglass, P.
    Visuri, S.
    Kolk, D.
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2012, 14 (06): : 693 - 693
  • [42] Determination of the Impact Damage Threshold Point of Composite Material Using Fuzzy-Base Taguchi Method
    Erbayrak, Seda
    Erbayrak, Engin
    JOURNAL OF ENGINEERING RESEARCH, 2020, 8 (03): : 153 - 171
  • [43] Fabrication of a novel electrochemical aptasensor assisted by a novel computerized monitoring system for real-time determination of the prostate specific antigen: A computerized experimental method brought elegancy
    Soleimani, Shokoufeh
    Arkan, Elham
    Jalalvand, Ali R.
    Goicoechea, Hector C.
    MICROCHEMICAL JOURNAL, 2020, 157
  • [44] A novel automated method for the determination of membrane permeability in gas-liquid transfer applications
    Ritchie, AC
    Bowry, K
    Fisher, AC
    Gaylor, JDS
    JOURNAL OF MEMBRANE SCIENCE, 1996, 121 (02) : 169 - 174
  • [45] A step towards standardization: A method for end-point titer determination by fluorescence index of an automated microscope. End-point titer determination by fluorescence index
    Carbone, Teresa
    Gilio, Michele
    Padula, Maria Carmela
    Tramontano, Giuseppina
    D'Angelo, Salvatore
    Pafundi, Vito
    JOURNAL OF IMMUNOLOGICAL METHODS, 2018, 456 : 67 - 71
  • [46] A novel flow injection chemiluminescence method for automated and miniaturized determination of phenols in smoked food samples
    Vakh, Christina
    Evdokimova, Ekaterina
    Pochivalov, Aleksei
    Moskvin, Leonid
    Bulatov, Andrey
    FOOD CHEMISTRY, 2017, 237 : 929 - 935
  • [47] ORPHAN PEAK ANALYSIS - A NOVEL METHOD FOR DETECTION OF POINT MUTATIONS USING AN AUTOMATED FLUORESCENCE DNA SEQUENCER
    HATTORI, M
    SHIBATA, A
    YOSHIOKA, K
    SAKAKI, Y
    GENOMICS, 1993, 15 (02) : 415 - 417
  • [48] A Novel Intelligent Load Control Switch Based on Dynamic Compensation Method for Current Zero-crossing Point
    Zheng, Guilin
    Zhang, Zhifu
    MATERIALS SCIENCE AND INFORMATION TECHNOLOGY, PTS 1-8, 2012, 433-440 : 4717 - 4724
  • [49] Surface Charge and Isoelectric Point of Leather: A Novel Determination Method and its Application in Leather Making
    Wang, Ya-nan
    Huang, Wanli
    Zhang, Hongshou
    Tian, Ling
    Zhou, Jianfei
    Shi, Bi
    JOURNAL OF THE AMERICAN LEATHER CHEMISTS ASSOCIATION, 2017, 112 (07): : 224 - 231
  • [50] Surface charge and isoelectric point of leather: A novel determination method and its application in leather making
    Zhou, Jianfei (zhouamao2004@126.com), 1600, American Leather Chemists Association (112):