Novel Computerized Method for Automated Determination of Ventilatory Threshold and Respiratory Compensation Point

被引:8
|
作者
Kim, Kyoung Jae [1 ]
Rivas, Eric [1 ]
Prejean, Brian [1 ]
Frisco, Dillon [2 ]
Young, Millennia [3 ]
Downs, Meghan [3 ]
机构
[1] KBR, Houston, TX 77002 USA
[2] JES Technol, Houston, TX USA
[3] NASA, Johnson Space Ctr, Houston, TX USA
基金
美国国家航空航天局;
关键词
incremental exercise; noninvasive measurement; ventilatory threshold; respiratory compensation point; automated determination; ANAEROBIC THRESHOLD; GAS-EXCHANGE; GENDER-DIFFERENCES; EXERCISE; LACTATE; ADAPTATION; DETECT; POWER; SEX;
D O I
10.3389/fphys.2021.782167
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Introduction: The ventilatory threshold (named as VT1) and the respiratory compensation point (named as VT2) describe prominent changes of metabolic demand and exercise intensity domains during an incremental exercise test.Methods: A novel computerized method based on the optimization method was developed for automatically determining VT1 and VT2 from expired air during a progressive maximal exercise test. A total of 109 peak cycle tests were performed by members of the US astronaut corps (74 males and 35 females). We compared the automatically determined VT1 and VT2 values against the visual subjective and independent analyses of three trained evaluators. We also characterized VT1 and VT2 and the respective absolute and relative work rates and distinguished differences between sexes.Results: The automated compared to the visual subjective values were analyzed for differences with t test, for agreement with Bland-Altman plots, and for equivalence with a two one-sided test approach. The results showed that the automated and visual subjective methods were statistically equivalent, and the proposed approach reliably determined VT1 and VT2 values. Females had lower absolute O-2 uptake, work rate, and ventilation, and relative O-2 uptake at VT1 and VT2 compared to men (p <= 0.04). VT1 and VT2 occurred at a greater relative percentage of their peak VO2 for females (67 and 88%) compared to males (55 and 74%; main effect for sex: p < 0.001). Overall, VT1 occurred at 58% of peak VO2, and VT2 occurred at 79% of peak VO2 (p < 0.0001).Conclusion: Improvements in determining of VT1 and VT2 by automated analysis are time efficient, valid, and comparable to subjective visual analysis and may provide valuable information in research and clinical practice as well as identifying exercise intensity domains of crewmembers in space.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] A Novel Point Target Attitude Compensation Method Using Electromagnetic Reflectance Theory
    Han, Yonghui
    Lu, Pingping
    Hou, Wentao
    Gao, Yao
    Wang, Robert
    REMOTE SENSING, 2023, 15 (09)
  • [32] A novel respiratory gating method based on automated analysis of ultrasonic diaphragm motion
    Xu, Q
    Hamilton, R
    MEDICAL PHYSICS, 2005, 32 (06) : 2124 - 2124
  • [33] A novel respiratory detection method based on automated analysis of ultrasound diaphragm video
    Xu, QY
    Hamilton, RJ
    MEDICAL PHYSICS, 2006, 33 (04) : 916 - 921
  • [34] A Novel Ambiguity Acceptance Test Threshold Determination Method with Controllable Failure Rate
    Wang, Lei
    Verhagen, Sandra
    Feng, Yanming
    PROCEEDINGS OF THE 27TH INTERNATIONAL TECHNICAL MEETING OF THE SATELLITE DIVISION OF THE INSTITUTE OF NAVIGATION (ION GNSS 2014), 2014, : 2494 - 2502
  • [35] Determination of the Respiratory Compensation Point by Detecting Changes in Intercostal Muscles Oxygenation by Using Near-Infrared Spectroscopy
    Contreras-Briceno, Felipe
    Espinosa-Ramirez, Maximiliano
    Keim-Bagnara, Vicente
    Carreno-Roman, Matias
    Rodriguez-Villagra, Rafael
    Villegas-Belmar, Fernanda
    Viscor, Gines
    Gabrielli, Luigi
    Andia, Marcelo E.
    Araneda, Oscar F.
    Hurtado, Daniel E.
    LIFE-BASEL, 2022, 12 (03):
  • [36] A novel automated computerized method measuring joint space narrowing in rheumatoid arthritis in a longitudinal study.
    de Pablo, P
    Finckh, A
    Katz, JN
    Wolfe, F
    Neumann, G
    Duryea, J
    ARTHRITIS AND RHEUMATISM, 2004, 50 (09): : S168 - S168
  • [37] The time from anaerobic threshold (AT) to respiratory compensation point reflects the rate of aerobic and anaerobic metabolism after the AT in chronic heart failure patients
    Tanehata, M
    Adachi, H
    Oshima, S
    Taniguchi, K
    Itoh, H
    Hasegawa, A
    Nagai, R
    JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1999, 63 (04): : 274 - 277
  • [38] A Novel Pallet Detection Method for Automated Guided Vehicles Based on Point Cloud Data
    Shao, Yiping
    Fan, Zhengshuai
    Zhu, Baochang
    Zhou, Minlong
    Chen, Zhihui
    Lu, Jiansha
    SENSORS, 2022, 22 (20)
  • [39] Determination of respiratory point compensation in healthy adults: Can non-invasive near-infrared spectroscopy help?
    Fontana, Federico Y.
    Keir, Daniel A.
    Bellotti, Cecilia
    De Roia, Gabriela F.
    Murias, Juan M.
    Pogliaghi, Silvia
    JOURNAL OF SCIENCE AND MEDICINE IN SPORT, 2015, 18 (05) : 590 - 595
  • [40] HPLC Method for Determination of Enantiomeric Purity of a Novel Respiratory Fluoroquinolone: WCK 1152
    Yeole, R. D.
    Lawand, S. V.
    Bhavsar, S. B.
    Deshpande, P. K.
    INDIAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2008, 70 (03) : 357 - 361