摘要
Radial variation of the gas holdup and mean holdups were investigated in a 0. 160 m W. bubble column using electrical resistance tomography with two axial locations (Plane 1 and Plane 2). In all the experiments tap water was used the liquid phase and air was the gas phase. Superficial gas velocity was varied from 0.02 to 0.25 m/s, and superficial liquid velocity varied from 0 to 0.011 m/s. The effect of liquid velocity on the mean holdups and radial gas holdup distribution was discussed. The experimental results showed the liquid velocity slightly influence the mean holdup and radial hold-ups distribution in the operating condition, and the liquid flow can improve the transition gas velocity for the homogeneous regime to heterogeneous regime. Meanwhile the mean gas holdups as a function of gas velocity were derived from using differential pressure method and electrical resistance tomography method. The agreement between results obtained by these two methods is generally very good in the homogeneous regime. But in the transition regime and heterogeneous regime, results with ERT are slightly larger than one with the differential pressure method. According to the experimental results, a correlation for the centreline holdup is obtained. (c) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:191 / 196
页数:6
相关论文
共 50 条
  • [32] Gas Holdup Characteristics in a Tapered Bubble Column
    Zhang, Kai
    Zhao, Yulong
    Zhang, Bijiang
    INTERNATIONAL JOURNAL OF CHEMICAL REACTOR ENGINEERING, 2003, 1
  • [33] Studies of gas holdup in bubble column reactors
    Jamialahmadi, M.
    Müller-Steinhagen, H.
    Sarrafi, A.
    Smith, J.M.
    Chemical Engineering and Technology, 2000, 23 (10): : 919 - 921
  • [34] Studies of gas holdup in bubble column reactors
    Jamialahmadi, M
    Müller-Steinhagen, H
    Sarrafi, A
    Smith, JM
    CHEMICAL ENGINEERING & TECHNOLOGY, 2000, 23 (10) : 919 - 921
  • [35] Gas holdup in trayed bubble column reactors
    Alvaré, J
    Al-Dahhan, MH
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2006, 45 (09) : 3320 - 3326
  • [36] Improved gas holdup in novel bubble column
    Dhanasekaran, S.
    Karunanithi, T.
    CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 2012, 90 (01): : 126 - 136
  • [37] Effect of fiber length distribution on gas holdup in a cocurrent air-water-fiber bubble column
    Tang, Chengzhi
    Heindel, Theodore J.
    CHEMICAL ENGINEERING SCIENCE, 2007, 62 (05) : 1408 - 1417
  • [38] Gas holdup profiles within annular section in a double tube bubble column
    Ohira, Y
    Takahashi, H
    Ando, K
    KAGAKU KOGAKU RONBUNSHU, 1997, 23 (02) : 181 - 187
  • [39] Gas holdup in bubble column bioreactors of small dimensions with gas-liquid-solid dispersions
    Gavrilescu, M
    Tudose, RZ
    REVUE ROUMAINE DE CHIMIE, 1997, 42 (07) : 551 - 563
  • [40] COCURRENT DOWNFLOW BUBBLE COLUMN WITH SIMULTANEOUS GAS-LIQUID INJECTION NOZZLE
    BANDO, Y
    KURAISHI, M
    NISHIMURA, M
    HATTORI, M
    ASADA, T
    JOURNAL OF CHEMICAL ENGINEERING OF JAPAN, 1988, 21 (06) : 607 - 612