Effect of fiber length distribution on gas holdup in a cocurrent air-water-fiber bubble column

被引:4
|
作者
Tang, Chengzhi [1 ]
Heindel, Theodore J. [1 ]
机构
[1] Iowa State Univ, Dept Mech Engn, Ames, IA 50011 USA
关键词
bubble column; fiber length distribution; fiber suspension; hydrodynamics; multiphase flow; voidage;
D O I
10.1016/j.ces.2006.11.042
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
An experimental investigation is reported on the effect of fiber length distribution on gas holdup in a cocurrent air-water-fiber bubble column. Different combinations of 1 and 3mm Rayon fibers are used to simulate different fiber length distributions. At a constant total fiber mass fraction, gas holdup generally decreases with increasing mass fraction of the 3mm Rayon fiber while other conditions remain constant. Crowding factors estimated using four different methods (N-c = N-c,N-A, N*(c), N-c,N-L, and N-c,N-M) and the parameters (Nc,LNf0.2)-N-0.8 and N-c,M(N,f)0.8(0.2) are tested on their performance to quantify the overall effects of fiber mass fraction and fiber length and its distribution on gas holdup. (Nc,LNf0.2)-N-0.8 and (Nc,MNf0.2)-N-0.8 provide the best characterization of the fiber effects on gas holdup in the cocurrent air-water-fiber bubble column. The crowding factor estimated using the model-based average fiber length (N-c,N-M) also provides a good characterization and is better than the other crowding factor definitions. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1408 / 1417
页数:10
相关论文
共 50 条
  • [1] Effect of fiber type on gas holdup in a cocurrent air-water-fiber bubble column
    Tang, CZ
    Heindel, TJ
    CHEMICAL ENGINEERING JOURNAL, 2005, 111 (01) : 21 - 30
  • [2] A gas holdup model for cocurrent air-water-fiber bubble colunms
    Tang, CZ
    Heindel, TJ
    CHEMICAL ENGINEERING SCIENCE, 2006, 61 (10) : 3299 - 3312
  • [3] Study of gas holdup in a cocurrent air/water/fiber system
    Schulz, Thomas H.
    Heindel, Theodore J.
    TAPPI Journal, 2000, 83 (06):
  • [4] A study of gas holdup in a cocurrent air/water/fiber system
    Schulz, TH
    Heindel, TJ
    INTERNATIONAL ENGINEERING CONFERENCE, BOOKS 1-3, 1998, : 957 - 978
  • [5] The effect of bubble column diameter on gas holdup in fiber suspensions
    Su, XF
    Hol, PD
    Talcott, SM
    Staudt, AK
    Heindel, TJ
    CHEMICAL ENGINEERING SCIENCE, 2006, 61 (10) : 3098 - 3104
  • [6] Gas-liquid-fiber flow in a cocurrent bubble column
    Tang, CZ
    Heindel, TJ
    AICHE JOURNAL, 2005, 51 (10) : 2665 - 2674
  • [7] Distribution of gas holdup in a bubble column
    Kato, Yasuo
    Nishinaka, Masayuki
    Morooka, Shigeharu
    Kagaku Kogaku Ronbunshu, 1975, 1 (05) : 530 - 533
  • [8] GAS HOLDUP IN THE BUBBLE COLUMN WITH COCURRENT AND COUNTERCURRENT GAS-LIQUID FLOW
    OTAKE, T
    TONE, S
    SHINOHARA, K
    JOURNAL OF CHEMICAL ENGINEERING OF JAPAN, 1981, 14 (04) : 338 - 340
  • [9] Estimating gas holdup via pressure difference measurements in a cocurrent bubble column
    Tang, Chengzhi
    Heindel, Theodore J.
    INTERNATIONAL JOURNAL OF MULTIPHASE FLOW, 2006, 32 (07) : 850 - 863
  • [10] EFFECT OF PRESSURE ON GAS HOLDUP IN A BUBBLE COLUMN AND A SLURRY BUBBLE COLUMN
    KOJIMA, H
    OKUMURA, B
    NAKAMURA, A
    JOURNAL OF CHEMICAL ENGINEERING OF JAPAN, 1991, 24 (01) : 115 - 117