Effect of fiber length distribution on gas holdup in a cocurrent air-water-fiber bubble column

被引:4
|
作者
Tang, Chengzhi [1 ]
Heindel, Theodore J. [1 ]
机构
[1] Iowa State Univ, Dept Mech Engn, Ames, IA 50011 USA
关键词
bubble column; fiber length distribution; fiber suspension; hydrodynamics; multiphase flow; voidage;
D O I
10.1016/j.ces.2006.11.042
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
An experimental investigation is reported on the effect of fiber length distribution on gas holdup in a cocurrent air-water-fiber bubble column. Different combinations of 1 and 3mm Rayon fibers are used to simulate different fiber length distributions. At a constant total fiber mass fraction, gas holdup generally decreases with increasing mass fraction of the 3mm Rayon fiber while other conditions remain constant. Crowding factors estimated using four different methods (N-c = N-c,N-A, N*(c), N-c,N-L, and N-c,N-M) and the parameters (Nc,LNf0.2)-N-0.8 and N-c,M(N,f)0.8(0.2) are tested on their performance to quantify the overall effects of fiber mass fraction and fiber length and its distribution on gas holdup. (Nc,LNf0.2)-N-0.8 and (Nc,MNf0.2)-N-0.8 provide the best characterization of the fiber effects on gas holdup in the cocurrent air-water-fiber bubble column. The crowding factor estimated using the model-based average fiber length (N-c,N-M) also provides a good characterization and is better than the other crowding factor definitions. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1408 / 1417
页数:10
相关论文
共 50 条
  • [21] HEAT-TRANSFER AND GAS HOLDUP STUDIES IN A BUBBLE COLUMN - AIR WATER SAND SYSTEM
    SAXENA, SC
    RAO, NS
    SAXENA, AC
    CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 1992, 70 (01): : 33 - 41
  • [22] Effects of column diameter and liquid height on gas holdup in air-water bubble columns
    Sasaki, Shohei
    Uchida, Kengo
    Hayashi, Kosuke
    Tomiyama, Akio
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2017, 82 : 359 - 366
  • [23] Distribution of gas holdup in a slurry bubble column with radiant orifice gas distributor
    Key Laboratory of Coal Gasification of Ministry of Education, Institute of Clean Coal Technology, East China University of Science and Technology, Shanghai 200237, China
    Huaxue Fanying Gongcheng Yu Gongyi, 2008, 2 (108-114):
  • [24] THE EFFECT OF ELECTROLYTES ON BUBBLE COALESCENCE AND GAS HOLDUP IN BUBBLE-COLUMN REACTORS
    ZAHRADNIK, J
    FIALOVA, M
    KASTANEK, F
    GREEN, KD
    THOMAS, NH
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 1995, 73 (A3): : 341 - 346
  • [25] Effect of gas density on large-bubble holdup in bubble column reactors
    Letzel, MH
    AICHE JOURNAL, 1998, 44 (10) : 2333 - 2336
  • [26] Modeling gas holdup in gas-liquid-fiber semibatch bubble columns
    Su, XF
    Heindel, TJ
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2005, 44 (24) : 9355 - 9363
  • [27] Gas holdup at dynamic equilibrium region of a bubble column: Effect of bubble generator performance
    Gong, Chun-Kai
    Xu, Xiao
    Yang, Qiang
    CHEMICAL ENGINEERING JOURNAL, 2022, 443
  • [28] SIMILITUDE ANALYSIS FOR GAS-LIQUID-FIBER FLOWS IN COCURRENT BUBBLE COLUMNS
    Tang, Chengzhi
    Heindel, Theodore J.
    PROCEEDINGS OF THE ASME FLUIDS ENGINEERING DIVISION SUMMER CONFERENCE, VOL 1, PTS A AND B, 2006, : 1787 - 1798
  • [29] EFFECT OF GAS-DENSITY ON HOLDUP IN A SUPERCRITICAL FLUID BUBBLE COLUMN
    RUSH, BJ
    SHAH, YT
    ABRAHAM, MA
    ACS SYMPOSIUM SERIES, 1993, 514 : 338 - 346
  • [30] A comparative study of gas holdup, bubble size distribution and interfacial area in a downflow bubble column
    Mandal, A
    Kundu, G
    Mukherjee, D
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2005, 83 (A4): : 423 - 428