Detection efficiency study of an imaging detector for low energy neutrons

被引:1
|
作者
BrauningDemian, A
Deodorico, W
SchmidtBocking, H
Dangendorf, V
Friedrich, H
Breskin, A
Chechik, R
Gibrekhterman, A
机构
关键词
D O I
10.1117/12.267852
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
High accuracy imaging of thermal neutrons has been demonstrated with detectors having solid converters coated with secondary electron emitters and coupled to gaseous electron multipliers. The present work concentrates on study of the neutron detection efficiency of detectors equipped with composite CsI coated Li-6 neutron converters. Monte Carlo simulations of the neutron conversion and the charged particle and electron emission processes permit to optimise the converter parameters. The experimental study of the detection efficiency is described in detail and the results are compared with the theoretical predictions.
引用
收藏
页码:562 / 565
页数:4
相关论文
共 50 条
  • [31] An integrating image detector for high energy neutrons
    Morris, C
    Armijo, V
    Atencio, LG
    Bridge, A
    Gavron, A
    Hart, G
    Morley, K
    Mottershead, T
    Yates, GJ
    Zumbro, J
    NEUTRONS IN RESEARCH AND INDUSTRY, INTERNATIONAL CONFERENCE, 1997, 2867 : 351 - 357
  • [32] A scintillation strip detector for detection of thermal neutrons
    Peresedov, V. F.
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2006, 49 (05) : 629 - 636
  • [33] An aerogel Cherenkov detector for multi-GeV photon detection with low sensitivity to neutrons
    Maeda, Y.
    Kawasaki, N.
    Masuda, T.
    Morii, H.
    Naito, D.
    Nakajima, Y.
    Nanjo, H.
    Nomura, T.
    Sasao, N.
    Seki, S.
    Shiomi, K.
    Sumida, T.
    Tajima, Y.
    PROGRESS OF THEORETICAL AND EXPERIMENTAL PHYSICS, 2015, 2015 (06):
  • [34] Study on the intrinsic detection efficiency of scintillator/Cherenkov detector for monitoring 14MeV neutrons by using foil activation method
    Shan Qing
    Fei Hao
    Li Liang
    Hu Zunhao
    Zhu Hongkui
    Jia Wenbao
    Ling Yongsheng
    Hei Daqian
    APPLIED RADIATION AND ISOTOPES, 2021, 174
  • [35] DETECTION EFFICIENCY OF A PLASTIC SCINTILLATOR FOR NEUTRONS IN THE ENERGY RANGE OF 1 TO 14 MEV
    GRASSLER, H
    TESCH, K
    NUCLEAR INSTRUMENTS & METHODS, 1961, 10 (04): : 353 - 355
  • [36] HIGH-SENSITIVITY SCINTILLATING-FIBER IMAGING DETECTOR FOR HIGH-ENERGY NEUTRONS
    RESS, D
    LERCHE, RA
    ELLIS, RJ
    HEATON, GW
    LEHR, DE
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (10): : 4943 - 4948
  • [37] CdTe hybrid pixel detector for imaging with thermal neutrons
    Jakubek, J
    Mettivier, G
    Montesi, MC
    Pospisil, S
    Russo, P
    Vacik, J
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 563 (01): : 238 - 241
  • [38] DETECTION OF LOW ENERGY NEUTRONS WITH A NAI(TI) CRYSTAL AND TIME OF FLIGHT
    BALLINI, R
    SHAFROTH, SM
    NUCLEAR INSTRUMENTS & METHODS, 1960, 6 (04): : 331 - 336
  • [39] Characterization of a silicon pixel detector for imaging with low energy radiation
    Caria, M
    Cadeddu, S
    Lai, A
    Sesselego, A
    Quarati, F
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 487 (1-2): : 170 - 174
  • [40] A 2 dimensional GMSD based imaging detector for neutrons
    Bateman, JE
    Derbyshire, GE
    Duxbury, DM
    Marsh, AS
    Rhodes, NJ
    Schooneveld, EM
    Spill, EJ
    Stephenson, R
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 470 - 474