Effect of UV system modifications on disinfection performance

被引:25
|
作者
Chiu, KP
Lyn, DA
Savoye, P
Blatchley, ER
机构
[1] Trojan Technol Inc, London, ON N5V 4T7, Canada
[2] Purdue Univ, Sch Civil Engn, W Lafayette, IN 47907 USA
[3] Ctr Int Rech Eau & Environm, Le Pecq, France
来源
关键词
D O I
10.1061/(ASCE)0733-9372(1999)125:5(459)
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Numerical simulations have been performed to gain a better understanding of ultraviolet (UV) disinfection process performance. Similar simulations in previous studies revealed critical paths through which particles moved and experienced low UV doses. In vertical UV systems, these paths generally are found near the channel walls with characteristics of high velocity and low turbulence intensity. Moreover, these paths generally coincide with low UV intensity zones and appear to represent the primary limitation of process performance. Reactor modifications have been designed to eliminate or modify these trajectories, thereby improving process performance. In a pilot-scale open-channel system with a vertical lamp orientation, two geometric modifications with "wave" and "baffle" shapes have been developed and examined. The results of these pilot tests confirmed the improvement of process performance when compared with an unmodified UV system. As in the case of the unmodified UV systems, a numerical model that combines kinetic information from a well-mixed batch reactor with a dose-distribution function was used to predict process performance of the UV system with the wave-shaped modification. A dose-distribution function that incorporates the effects of spatial nonuniformities in both hydrodynamics (through a random-walk model) and UV intensity (through a point-source-summation model) was developed. The dose-response function for microorganisms was obtained from completely mixed batch reactor experiments with a collimated beam. Predictions of disinfection efficacy confirmed the ability of the modified systems to improve microbial inactivation.
引用
收藏
页码:459 / 469
页数:11
相关论文
共 50 条
  • [11] Lightweight UV-C disinfection system
    She, Rosemary C.
    Chen, Dongyu
    Pak, Pil
    Armani, Deniz K.
    Schubert, Andreas
    Armani, Andrea M.
    BIOMEDICAL OPTICS EXPRESS, 2020, 11 (08): : 4326 - 4332
  • [12] A Novel System for Water Disinfection with UV Radiation
    Younis, Bassam A.
    Mahoney, Laura
    Palomo, Nicholas
    WATER, 2018, 10 (09)
  • [13] Modified UV disinfection system meets specifications
    Hymel, Robert
    Public Works, 1998, 129 (02):
  • [14] Disinfection performance using a UV/persulfate system: effects derived from different aqueous matrices
    Moreno-Andres, Javier
    Rios Quintero, Ruben
    Acevedo-Merino, Asuncion
    Nebot, Enrique
    PHOTOCHEMICAL & PHOTOBIOLOGICAL SCIENCES, 2019, 18 (04) : 878 - 883
  • [15] Performance of UV disinfection and the microbial quality of greywater effluent along a reuse system for toilet flushing
    Friedler, Eran
    Gilboa, Yael
    SCIENCE OF THE TOTAL ENVIRONMENT, 2010, 408 (09) : 2109 - 2117
  • [16] Disinfection performance using a UV/persulfate system: effects derived from different aqueous matrices
    Javier Moreno-Andrés
    Rubén Rios Quintero
    Asunción Acevedo-Merino
    Enrique Nebot
    Photochemical & Photobiological Sciences, 2019, 18 : 878 - 883
  • [17] UV-LED disinfection of Coronavirus: Wavelength effect
    Gerchman, Yoram
    Mamane, Hadas
    Friedman, Nehemya
    Mandelboim, Michal
    JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY B-BIOLOGY, 2020, 212
  • [18] The Effect of UV and Combined Chlorine/UV Treatment on Coliphages in Drinking Water Disinfection
    Zyara, Alyaa M.
    Torvinen, Eila
    Veijalainen, Anna-Maria
    Heinonen-Tanski, Helvi
    WATER, 2016, 8 (04):
  • [19] Performance evaluation of the UV disinfection reactors by CFD and fluence simulations using a concept of disinfection efficiency
    Pan, Huachen
    Orava, Marika
    JOURNAL OF WATER SUPPLY RESEARCH AND TECHNOLOGY-AQUA, 2007, 56 (03): : 181 - 189
  • [20] Development of UV distribution model for the non-contact type UV disinfection system
    Kim S.H.
    Choi Y.G.
    Kim D.
    International Journal of Chemical Reactor Engineering, 2011, 9