Orthodontic mini-implant stability at different insertion depths Sensitivity of three stability measurement methods

被引:0
|
作者
Nienkemper, Manuel [1 ]
Santel, Natascha [1 ]
Hoenscheid, Ralf [1 ]
Drescher, Dieter [1 ]
机构
[1] Univ Dusseldorf, Dept Orthodont, Moorenstr 5, D-40225 Dusseldorf, Germany
关键词
Orthodontics; Skeletal anchorage; Insertion depth; Mini-implants; Models animal; RESONANCE FREQUENCY-ANALYSIS; DAMPING CAPACITY ASSESSMENT; IN-VITRO; INTERFACE; DIAMETER; IMPACT;
D O I
10.1007/s00056-016-0036-2
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The purpose of this work was to evaluate the influence of insertion depth on the stability of orthodontic mini-implants. Sensitivity of three different methods to measure implant stability based on differences in insertion depth were determined. A total of 82 mini-implants (2 x 9 mm) were inserted into pelvic bone of Swabian Hall pigs. Each implant was inserted stepwise to depths of 4, 5, 6, 7, and 8 mm. At each of these depths, three different methods were used to measure implant stability, including maximum insertion torque (MIT), resonance frequency analysis (RFA), and Periotest(A (R)). Differences between the recorded values were statistically analyzed and the methods tested for correlations. Almost linear changes from each insertion depth were measured with the values of RFA [implant stability quotient (ISQ) values range from 1-100], which increased from 6.95 +/- 2.85 ISQ at 4 mm to 34.63 +/- 5.51 ISQ at 8 mm, and with those of Periotest(A (R)) [periotest values (PTV) range from -8 to 50], which decreased from 13.24 +/- 4.03 PTV to -2.89 +/- 1.87 PTV. Both methods were found to record highly significant (p < 0.0001) changes for each additional millimeter of insertion depth. The MIT increased significantly (p < 0.0001) from 153.67 +/- 69.32 Nmm to 261 +/- 103.73 Nmm between 4 and 5 mm of insertion depth but no further significant changes were observed as the implants were driven deeper. The RFA and Periotest(A (R)) values were highly correlated (r = -0.907). Mini-implant stability varies significantly with insertion depth. The RFA and the Periotest(A (R)) yielded a linear relationship between stability and insertion depth. MIT does not appear to be an adequate method to determine implant stability based on insertion depth.
引用
收藏
页码:296 / 303
页数:8
相关论文
共 50 条
  • [21] Finite element simulation and statistical investigation of an orthodontic mini-implant's stability in a novel screw design
    Pouyafar, Vahid
    Meshkabadi, Ramin
    Sadr Haghighi, Amir Hooman
    Navid, Ali
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2021, 235 (09) : 1046 - 1057
  • [22] The effect of varying healing times on orthodontic mini-implant stability: a microscopic computerized tomographic and biomechanical analysis
    Zhang, Qiang
    Zhao, Lixing
    Wu, Yeke
    Wang, Hui
    Zhao, Zhihe
    Xu, Zhenrui
    Wei, Xing
    Tang, Tian
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2011, 112 (04): : 423 - 429
  • [23] Er:YAG laser, piezosurgery, and surgical drill for bone decortication during orthodontic mini-implant insertion: primary stability analysis—an animal study
    Jacek Matys
    Rafał Flieger
    Gianluca Tenore
    Kinga Grzech-Leśniak
    Umberto Romeo
    Marzena Dominiak
    Lasers in Medical Science, 2018, 33 : 489 - 495
  • [24] A healing period increases mini-implant stability in growing rats
    Yano, Shinya
    Motoyoshi, Mitsuru
    Inaba, Mizuki
    Yano, Saori
    Takenouchi, Hiroyuki
    Son, Seil
    Arai, Yoshinori
    Shimizu, Noriyoshi
    JOURNAL OF ORAL SCIENCE, 2014, 56 (02) : 113 - 118
  • [25] Three-dimensional finite element analysis of the deformation of the human mandible: a preliminary study from the perspective of orthodontic mini-implant stability
    Baek, Sun-Hye
    Cha, Hyun-Suk
    Cha, Jung-Yul
    Moon, Yoon-Shik
    Sung, Sang-Jin
    KOREAN JOURNAL OF ORTHODONTICS, 2012, 42 (04) : 159 - 168
  • [26] Influence of different implant materials on the primary stability of orthodontic mini-implants
    Pan, Chin-Yun
    Chou, Szu-Ting
    Tseng, Yu-Chuan
    Yang, Yi-Hsin
    Wu, Chao-Yi
    Lan, Ting-Hsun
    Liu, Pao-Hsin
    Chang, Hong-Po
    KAOHSIUNG JOURNAL OF MEDICAL SCIENCES, 2012, 28 (12): : 673 - 678
  • [27] How Does Orthodontic Mini-Implant Thread Minidesign Influence the Stability?-Systematic Review with Meta-Analysis
    Jedlinski, Maciej
    Janiszewska-Olszowska, Joanna
    Mazur, Marta
    Grocholewicz, Katarzyna
    Suquia, Pedro Suarez
    Quintanilla, David Suarez
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (18)
  • [28] The effects of different pilot-drilling methods on the mechanical stability of a mini-implant system at placement and removal: a preliminary study
    Cho, Il-Sik
    Choo, HyeRan
    Kim, Seong-Kyun
    Shin, Yun-Seob
    Kim, Duck-Su
    Kim, Seong-Hun
    Chung, Kyu-Rhim
    Huang, John C.
    KOREAN JOURNAL OF ORTHODONTICS, 2011, 41 (05): : 354 - 360
  • [29] Er:YAG laser, piezosurgery, and surgical drill for bone decortication during orthodontic mini-implant insertion: primary stability analysis-an animal study
    Matys, Jacek
    Flieger, Rafa
    Tenore, Gianluca
    Grzech-Lesniak, Kinga
    Romeo, Umberto
    Dominiak, Marzena
    LASERS IN MEDICAL SCIENCE, 2018, 33 (03) : 489 - 495
  • [30] Pre-drilling force and insertion torques during orthodontic mini-implant insertion in relation to root contact
    Wilmes, Benedict
    Su, Yu-Yu
    Sadigh, Lilian
    Drescher, Dieter
    JOURNAL OF OROFACIAL ORTHOPEDICS-FORTSCHRITTE DER KIEFERORTHOPADIE, 2008, 69 (01): : 51 - 58