Experimental and clinical evaluation of iterative reconstruction (OSEM) in dynamic PET: Quantitative characteristics and effects on kinetic modeling

被引:0
|
作者
Boellaard, R [1 ]
van Lingen, A [1 ]
Lammertsma, AA [1 ]
机构
[1] Univ Hosp Vrije Univ, Clin PET Ctr, NL-1007 MB Amsterdam, Netherlands
关键词
iterative reconstruction; dynamic PET; quantitative accuracy; kinetic modeling;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study was to investigate the quantitative properties and effects of ordered-subset expectation maximization (OSEM) on kinetic modeling compared with filtered backprojection (FBP) in dynamic PET studies. Both phantom and patient studies were performed. Methods: For phantom studies dynamic two-dimensional emission scans with 10-min frames and 20-min scan intervals were acquired over a 14-h period using an HR+ PET scanner. Various phantoms were scanned: 2-, 5-, 10-, and 20-cm-diameter phantoms filled with an F-18 solution (300 kBq/ml) and a NEMA phantom filled with an F-18 background (40 kBq/ml) and a cold or C-11 insert (450 kBq/ml). Transmission (Tx) scans of 5-60 min were acquired. Data were reconstructed using FBP Hanning 0.5 and OSEM with 2-12 iterations and 12 or 24 subsets. Quantitative accuracy and noise characteristics were assessed. For patient studies, five cardiac, three oncologic, and three brain dynamic F-18-FDG scans were used. Five reconstructions were performed: FBP Hanning 0.5, and OSEM 2 x 12 and OSEM 4 x 16 with and without 5-mm full width at half maximum smoothing. Time-activity curves were calculated using volumes of interest. The input function was derived from arterial sampling. Metabolic rate of glucose (MRglu) was calculated with a standard two-tissue compartment model and Patlak analysis. Results: Contribution of Tx noise to the reconstructed image was smaller for OSEM than for FBP. Differences in signal-to-noise ratio between FBP and OSEM depended on number of iterations and phantom size, Bias with OSEM was observed for regions enclosed within a 5- to 10-fold hotter background. For cardiac studies OSEM 2 x 12 and OSEM 4 x 16 resulted in 13% and 21% higher pixel values and 9% and 15% higher MRglu values compared with FBP. Smoothing decreased all these values to 2%, Similar results were found for most tumor studies. For brain studies MRglu of FBP and OSEM 4 x 16 agreed within 2%. Use of OSEM image-derived input functions for cardiac PET studies resulted in a decrease in calculated MRglu of about 15%. Conclusion: For most PET studies OSEM has equal quantitative accuracy as FBP. The higher pixel and MRglu values are explained by the better resolution of OSEM. However, OSEM does not provide accurate image-derived input functions for FDG cardiac PET studies because of bias in regions located within a hotter background.
引用
收藏
页码:808 / 817
页数:10
相关论文
共 50 条
  • [31] Evaluation of dynamic row-action maximum likelihood algorithm reconstruction for quantitative 15O brain PET
    Masanobu Ibaraki
    Kaoru Sato
    Tetsuro Mizuta
    Keishi Kitamura
    Shuichi Miura
    Shigeki Sugawara
    Yuki Shinohara
    Toshibumi Kinoshita
    Annals of Nuclear Medicine, 2009, 23 : 627 - 638
  • [32] Evaluation of dynamic row-action maximum likelihood algorithm reconstruction for quantitative 15O brain PET
    Ibaraki, Masanobu
    Sato, Kaoru
    Mizuta, Tetsuro
    Kitamura, Keishi
    Miura, Shuichi
    Sugawara, Shigeki
    Shinohara, Yuki
    Kinoshita, Toshibumi
    ANNALS OF NUCLEAR MEDICINE, 2009, 23 (07) : 627 - 638
  • [33] Dynamic PET imaging of tetrahedral DNA nanoparticles enables quantitative evaluation of kidney function via mathematical modeling
    Jiang, Dawei
    Ni, Dalong
    Kang, Lei
    Wei, Weijun
    Engle, Jonathan
    Cai, Weibo
    JOURNAL OF LABELLED COMPOUNDS & RADIOPHARMACEUTICALS, 2019, 62 : S357 - S358
  • [34] Kinetic modeling and parametric imaging with dynamic PET for oncological applications: general considerations, current clinical applications, and future perspectives
    Dimitrakopoulou-Strauss, Antonia
    Pan, Leyun
    Sachpekidis, Christos
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2021, 48 (01) : 21 - 39
  • [35] Kinetic modeling and parametric imaging with dynamic PET for oncological applications: general considerations, current clinical applications, and future perspectives
    Antonia Dimitrakopoulou-Strauss
    Leyun Pan
    Christos Sachpekidis
    European Journal of Nuclear Medicine and Molecular Imaging, 2021, 48 : 21 - 39
  • [36] RECONSTRUCTION OF DYNAMIC PET IMAGES USING ACCURATE SYSTEM POINT SPREAD FUNCTION MODELING: EFFECTS ON PARAMETRIC IMAGES
    D'Ambrosio, D.
    Fiacchi, G.
    Marengo, M.
    Boschi, S.
    Fanti, S.
    Spinelli, A. E.
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2010, 10 (01) : 73 - 94
  • [37] Experimental evaluation of filtered back projection versus iterative reconstruction using statistical parametric mapping analysis of PET activation studies.
    Mesina, CT
    Boellaard, R
    Jongbloed, G
    Vaart van Der, AW
    Lammertsma, AA
    JOURNAL OF NUCLEAR MEDICINE, 2002, 43 (05) : 218P - 218P
  • [38] Partial Volume Correction of Small Animal PET Cardiac Dynamic Images Using Iterative Reconstruction: Effects on Glucose Metabolic Rate Measurement
    D'Ambrosio, D.
    Fiacchi, G.
    Cilibrizzi, P.
    Lamberti, C.
    Baldazzi, G.
    Boschi, S.
    Franchi, R.
    Marengo, M.
    Spinelli, A. E.
    COMPUTERS IN CARDIOLOGY 2008, VOLS 1 AND 2, 2008, : 1093 - +
  • [39] Evaluation of Quantitative Whole Body Dynamic FDG-PET Using Block Sequence Regularized Expectation Maximization (BSREM) Reconstruction
    Kaeck, Alexander
    Hurley, Samuel
    Bradshaw, Tyler
    Perlman, Scott
    Cho, Steve
    McMillan, Alan
    JOURNAL OF NUCLEAR MEDICINE, 2019, 60
  • [40] Experimental and kinetic modeling investigation on ignition characteristics of hydrogen: effects of methane co-firing and dilution gas
    Tian, Xiaojing
    Liu, Songlin
    Fang, Jun
    Zhang, Qiying
    Feng, Zhenzhen
    Fang, Qilong
    PROGRESS IN REACTION KINETICS AND MECHANISM, 2024, 49