Chemiluminescent flow-through sensor for hydrogen peroxide based on sol-gel immobilized hemoglobin as catalyst

被引:33
|
作者
Li, BX [1 ]
Zhang, ZJ [1 ]
Zhao, LX [1 ]
机构
[1] Shaanxi Normal Univ, Dept Chem, Xian 710062, Peoples R China
基金
中国国家自然科学基金;
关键词
chemiluminescence; flow-through sensor; sol-gel method; hydrogen peroxide; hemoglobin;
D O I
10.1016/S0003-2670(01)01284-3
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel chemiluminescence (CL) flow-through sensor for hydrogen peroxide is described. It is prepared by immobilizing hemoglobin (Hb) with the sol-gel method on the flow cell, and by electrostatically immobilizing luminol on strongly basic anion-exchange resin. Hydrogen peroxide is sensed by the CL reaction with Hb sensitive membrane and luminol bleeding from the ion-exchange column with immobilized luminol by hydrolysis. The calibration graph is linear in the range of 6 x 10(-5) to 4 x 10(-7) mol l(-1) with a detection limit of 1.3 x 10(-7) mol l(-1) (3 sigma). A complete analysis could be performed in I min with a relative standard deviation of 1.7% for 5 x 10(-6) mol l(-1) H2O2 (n = 9). The sensor has been applied successfully to the determination of hydrogen peroxide in rainwater. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:161 / 167
页数:7
相关论文
共 50 条
  • [41] Sol-gel immobilized biocatalyst for continuous-flow enantioselective acylation
    Paul, Cristina
    Borza, Paula
    Todea, Anamaria
    Peter, Francisc
    NEW BIOTECHNOLOGY, 2016, 33 : S104 - S104
  • [42] Amperometric enzyme electrode for the determination of hydrogen peroxide based on sol-gel/hydrogel composite film
    Wang, BQ
    Zhang, JZ
    Cheng, GJ
    Dong, SJ
    ANALYTICA CHIMICA ACTA, 2000, 407 (1-2) : 111 - 118
  • [43] Silica sol-gel immobilized amperometric enzyme electrode for peroxide determination in the organic phase
    Li, J
    Tan, SN
    Oh, JT
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1998, 448 (01): : 69 - 77
  • [44] Electrocatalytic Sensor for Hydrogen Peroxide Based on Immobilized Benzoquinone
    Laroussi, Arwa
    Raouafi, Noureddine
    Mirsky, Vladimir M.
    ELECTROANALYSIS, 2021, 33 (09) : 2062 - 2070
  • [45] Silicate sol-gel stabilized silver nanoparticles for sensor applications toward mercuric ions, hydrogen peroxide and nitrobenzene
    Rameshkumar, Perumal
    Viswanathan, Perumal
    Ramaraj, Ramasamy
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 202 : 1070 - 1077
  • [46] Behavior of immobilized Alizarin Red S into sol-gel matrix as pH sensor
    Zaggout, Farid R.
    Qarraman, Abed El-Fattah A.
    Zourab, Shehata M.
    MATERIALS LETTERS, 2007, 61 (19-20) : 4192 - 4195
  • [47] Chemiluminescent flow-through sensor for 1,10-phenanthroline based on the combination of molecular imprinting and chemiluminescence
    Lin, JM
    Yamada, M
    ANALYST, 2001, 126 (06) : 810 - 815
  • [48] Sol-gel based optical sensor for dissolved ammonia
    Lobnik, A
    Wolfbeis, OS
    SENSORS AND ACTUATORS B-CHEMICAL, 1998, 51 (1-3) : 203 - 207
  • [49] Sol-gel based optical sensor for dissolved ammonia
    Lobnik, Aleksandra
    Wolfbeis, Otto S.
    Sensors and Actuators, B: Chemical, 1998, B51 (1-3): : 203 - 207
  • [50] Sol-gel based sensor for selective formaldehyde determination
    Bunkoed, Opas
    Davis, Frank
    Kanatharana, Proespichaya
    Thavarungkul, Panote
    Higson, Seamus P. J.
    ANALYTICA CHIMICA ACTA, 2010, 659 (1-2) : 251 - 257