Electrocatalytic Sensor for Hydrogen Peroxide Based on Immobilized Benzoquinone

被引:5
|
作者
Laroussi, Arwa [1 ,2 ]
Raouafi, Noureddine [1 ]
Mirsky, Vladimir M. [2 ]
机构
[1] Univ Tunis El Manar, Fac Sci Tunis, Chem Dept, Lab Analyt Chem & Electrochem LR99ES15, Campus Univ Tunis El Manar, Tunis El Manar 2092, Tunisia
[2] Brandenburg Univ Technol Cottbus Senftenberg, Inst Biotechnol, Dept Nanobiotechnol, D-01968 Senftenberg, Germany
关键词
Hydrogen peroxide; Chemical sensor; Electrocatalysis; Benzoquinone; Self-assembled monolayer; SELF-ASSEMBLED MONOLAYERS; FERROCENE-FUNCTIONALIZED GRAPHENE; GOLD; OXIDATION; ELECTRODE; COMPOSITE; H2O2; REDUCTION; BEHAVIOR; FILM;
D O I
10.1002/elan.202100113
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An amperometric chemosensor for the detection of hydrogen peroxide is reported. The sensor is based on 1,4-benzoquinone immobilized on the gold electrode using self-assembled monolayer of short chain symmetrical dithiol as an anchor layer. Sensor analysis was performed by cyclic voltammetry at the potential range from -0.6 V till +0.9 V as well as in the anodic or cathodic potential ranges only. The results indicate oxidative electrochemical decomposition of hydrogen peroxide at the potential of similar to+0.4 V leading to the formation of oxygen while at cathodic potentials a reduction of the formed oxygen as well as of the hydrogen peroxide occur. A decrease in the oxidation potential of hydrogen peroxide on the gold electrode coated by self-assembled monolayer with 1,4-benzoquinone in comparison with that measured on the electrodes coated by the same self-assembled monolayer without 1,4-benzoquinone, indicates electrocatalytic effect of this moiety on oxidative decomposition of hydrogen peroxide. Analytical evaluation of the sensor performance was done in the voltammetric as well as in the chronoamperometric mode. The sensor exhibited linear response over the concentration range till 2.5 mM with a limit of detection similar to 4 mu M.
引用
收藏
页码:2062 / 2070
页数:9
相关论文
共 50 条
  • [1] Hydrogen peroxide sensor based on horseradish peroxide (HRP) immobilized PANI electrode with Au nanoparticles
    Seo, Kang-Deuk
    Oh, Seong-Dae
    Choi, Seong-Ho
    Oh, Sang-Hyub
    Woo, Jin-Chun
    Park, Hae-Jun
    ASBM7: ADVANCED BIOMATERIALS VII, 2007, 342-343 : 865 - +
  • [2] A hydrogen peroxide sensor based on myoglobin immobilized in DNA films on a gold electrode
    Wu, Wei-Li
    Zhang, Da-Peng
    Chen, Xi
    Liu, Yun-Chun
    Yang, Zhou-Sheng
    CANADIAN JOURNAL OF ANALYTICAL SCIENCES AND SPECTROSCOPY, 2008, 53 (01): : 1 - 11
  • [3] Hydrogen peroxide sensor based on horseradish peroxidase immobilized nanostructured cerium oxide film
    Ansari, Anees A.
    Solanki, Pratima R.
    Malhotra, B. D.
    JOURNAL OF BIOTECHNOLOGY, 2009, 142 (02) : 179 - 184
  • [4] Horse radish peroxidase immobilized polyaniline for hydrogen peroxide sensor
    Solanki, Pratima R.
    Kaushik, Ajeet
    Ansari, Anees A.
    Sumana, G.
    Malhotra, B. D.
    POLYMERS FOR ADVANCED TECHNOLOGIES, 2011, 22 (06) : 903 - 908
  • [5] Hydrogen peroxide sensor using immobilized maganese dioxide membrane
    Nagata, R
    Gondo, S
    Uemura, Y
    Hatate, Y
    KAGAKU KOGAKU RONBUNSHU, 2000, 26 (01) : 108 - 111
  • [6] Hydrogen peroxide sensor based on horseradish peroxidase immobilized on a silver nanoparticles/cysteamine/gold electrode
    Chunbo Ren
    Yonghai Song
    Zhuang Li
    Guoyi Zhu
    Analytical and Bioanalytical Chemistry, 2005, 381 : 1179 - 1185
  • [7] A novel hydrogen peroxide sensor based on horseradish peroxidase immobilized in DNA films on a gold electrode
    Song, YH
    Wang, L
    Ren, CB
    Zhu, GY
    Li, Z
    SENSORS AND ACTUATORS B-CHEMICAL, 2006, 114 (02) : 1001 - 1006
  • [8] Hydrogen peroxide sensor based on horseradish peroxidase immobilized on a silver nanoparticles/cysteamine/gold electrode
    Ren, CB
    Song, YH
    Li, Z
    Zhu, GY
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 381 (06) : 1179 - 1185
  • [9] HYDROGEN-PEROXIDE SENSOR SYSTEM USING IMMOBILIZED LUMINOUS BACTERIUM
    SAGA, K
    KOBAYASHI, T
    SHIMIZU, S
    AGRICULTURAL AND BIOLOGICAL CHEMISTRY, 1981, 45 (12): : 2895 - 2897
  • [10] Flow-injection chemiluminescence sensor for hydrogen peroxide with immobilized reagents
    Li, BX
    Qin, W
    Zhang, ZJ
    CHINESE CHEMICAL LETTERS, 1998, 9 (05) : 471 - 472