Precision of maxillo-mandibular registration with intraoral scanners in vitro

被引:46
|
作者
Gintaute, A. [1 ]
Keeling, A. J. [2 ]
Osnes, C. A. [2 ,3 ]
Zitzmann, N. U. [1 ]
Ferrari, M. [4 ,5 ]
Joda, T. [1 ]
机构
[1] Univ Ctr Dent Med Basel, Dept Reconstruct Dent, Hebelstr 7, CH-4056 Basel, Switzerland
[2] Univ Leeds, Sch Dent, Dept Restorat Dent, Leeds, W Yorkshire, England
[3] Univ Siena, Dept Med Biotechnol, Siena, Italy
[4] Univ Siena, Sch Dent Med, Dept Prosthodont & Dent Mat, Siena, Italy
[5] Univ Leeds, Sch Dent, Dent Trial Clin Res Unit DenTCRU, Leeds, W Yorkshire, England
关键词
Intraoral optical scan (IOS); Dental occlusion [MeSH; Bite registration; Digital dentistry; Precision; DENTAL IMPRESSIONS; ACCURACY;
D O I
10.1016/j.jpor.2019.05.006
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To compare the precision of maxillo-mandibular registration and resulting full arch occlusion produced by three intraoral scanners in vitro. Methods: Six dental models (groups A-F) were scanned five times with intraoral scanners (CEREC, TRIOS, PLANMECA), producing both full arch and two buccal maxillo-mandibular scans. Total surface area of contact points (defined as regions within 0.1 mm and all mesh penetrations) was measured, and the distances between four pairs of key points were compared, each two in the posterior and anterior. Results: Total surface area of contact points varied significantly among scanners across all groups. CEREC produced the smallest contact surface areas (5.7-25.3 mm(2)), while PLANMECA tended to produce the largest areas in each group (22.2-60.2 mm(2)). Precision of scanners, as measured by the 95% CI range, varied from 0.1-0.9 mm for posterior key points. For anterior key points the 95% CI range was smaller, particularly when multiple posterior teeth were still present (0.04-0.42 mm). With progressive loss of posterior units (groups D-F), differences in the anterior occlusion among scanners became significant in five out of six groups (D-F left canines and D, F right canines, p <0.05). Conclusions: Maxillo-mandibular registrations from three intraoral scanners created significantly different surface areas of occlusal contact. Posterior occlusions revealed lower precision for all scanners than anterior. CEREC tended towards incorrect posterior open bites, whilst TRIOS was most consistent in reproducing occluding units. (C) 2019 Japan Prosthodontic Society. Elsevier Ltd. All rights reserved.
引用
收藏
页码:114 / 119
页数:6
相关论文
共 50 条
  • [31] Trueness and Precision of Two Intraoral Scanners: A Comparative In Vitro Study
    Rotar, Raul Nicolae
    Jivanescu, Anca
    Ille, Codruta
    Podariu, Angela Codruta
    Jumanca, Daniela Elisabeta
    Matichescu, Ana-Maria
    Balean, Octavia
    Rusu, Laura Cristina
    SCANNING, 2019, 2019
  • [32] Influence of the Number of Teeth and Location of the Virtual Occlusal Record on the Accuracy of the Maxillo-Mandibular Relationship Obtained by Using An Intraoral Scanner
    Revilla-Leon, Marta
    Alonso Perez-Barquero, Jorge
    Zubizarreta-Macho, Alvaro
    Barmak, Abdul B.
    Att, Wael
    Kois, John C.
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2023, 32 (03): : 253 - 258
  • [33] Simultaneous intraoral rotational distraction osteogenesis of the maxillo-mandibular complex for treatment of Treacher-Collins syndrome with sleep apnea
    Takenobu, T
    Mitsugi, M
    Yamanouchi, T
    Alcalde, RE
    Furutani, M
    3RD INTERNATIONAL CONGRESS ON CRANIAL AND FACIAL BONE DISTRACTION PROCESSES: 2001 DISTRACTION ODYSSEY, 2001, : 325 - 328
  • [34] Assessment of Maxillo-Mandibular Implant Sites by Digitized Volumetric Tomography
    Dubey, A.
    Dangorekhasbage, S.
    Bhowate, R.
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2019, 8 (50): : 3780 - 3784
  • [35] Evaluation of dammages to the maxillo-mandibular complex from interpersonal violence
    Frugoli, UO
    Ramos, DG
    Cardozo, HF
    Muñoz, DR
    JOURNAL OF DENTAL RESEARCH, 2001, 80 (04) : 1016 - 1016
  • [36] Syngnathia: a rare case of maxillo-mandibular fusion in an adult patient
    Friscia, Marco
    Bonavolonta, Paola
    Arena, Antonio
    Committeri, Umberto
    Maglitto, Fabio
    Salzano, Giovanni
    Iaconetta, Giorgio
    Califano, Luigi
    CHIRURGIA-ITALY, 2020, 33 (01): : 65 - 69
  • [37] Correlation between the Atlas Morphology and the Maxillo-mandibular Divergence Pattern
    Mahmood, Hafiz Taha
    Fida, Mubassar
    JCPSP-JOURNAL OF THE COLLEGE OF PHYSICIANS AND SURGEONS PAKISTAN, 2018, 28 (09): : 690 - 694
  • [38] An in vitro study in separating tensile loads during maxillo-mandibular fixation using wire and/or elastics
    Pawa, Sudeep
    Visuttiwattanakorn, Surakit
    PLOS ONE, 2024, 19 (03):
  • [39] Impact of maxillo-mandibular advancement on quality of life in OSAS patients
    Lagana, F.
    Rossi, D.
    Beltramini, G.
    Romano, M.
    Russillo, A.
    Gianni, A.
    SLEEP MEDICINE, 2015, 16 : S193 - S193
  • [40] Effect of Different Intraoral Scanners on the Accuracy of Bite Registration in Edentulous Maxillary and Mandibular Arches
    Rutkunas, Vygandas
    Jegelevicius, Darius
    Gedrimiene, Agne
    Auskalnis, Liudas
    Eyuboglu, Tan Firat
    Ozcan, Mutlu
    Husain, Nadin Al-Haj
    Akulauskas, Mykolas
    Pletkus, Justinas
    JOURNAL OF DENTISTRY, 2024, 146