Microdosimetric specification of the radiation quality of a d(48.5)+Be fast neutron therapy beam produced by a superconducting cyclotron

被引:9
|
作者
Kota, C [1 ]
Maughan, RL [1 ]
机构
[1] WAYNE STATE UNIV,DETROIT,MI 48201
关键词
radiotherapy; neutrons; microdosimetry; radiation quality;
D O I
10.1118/1.597896
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The proportional counter microdosimetric technique has been employed to quantify variations in the quality of a d(48.5)+Be fast neutron beam passing through a homogeneous water phantom. Single event spectra have been measured as a function of spatial location in the water phantom and field size. The measured spectra have been separated into component spectra corresponding to the gamma, recoil proton and alpha plus heavy recoil ion contribution to the total absorbed dose. The total absorbed dose normalized to the ''monitor units'' used in daily clinical use has been calculated from the measured spectra and compared to the data measured with calibrated ion chambers. The present measurements agree with the ion chamber data to within 5%. The RBE of the neutron beam is assumed to be proportional to the microdosimetric parameter gamma* for the dose ranges pertinent to fractionated neutron therapy. The relative variations in gamma*, assumed to be representative of variations in the RBE are mapped as a function of field size and spatial location in the phantom. A variation in the RBE of about 4% for points within and 8% for points outside a 10 cmX10 cm field is observed. The variations in the RBE within the beam are caused by an increase in the gamma component with depth. An increase in the RBE of about 4% is observed with increasing field size which is attributed to a change in the neutron spectrum. Compared to the uncertainties in the prescribed dose, associated with uncertainties in the clinically used RBE, variation in the RBE between various tissues, and other dosimetric uncertainities caused by factors such as patient inhomogeneities, patient setup errors, patient motion, etc., the measured spatial RBE variations are not considered significant enough to be incorporated into the treatment planning scheme. (C) 1996 American Association of Physicists in Medicine.
引用
收藏
页码:1591 / 1599
页数:9
相关论文
共 38 条
  • [21] FAST-NEUTRON THERAPY BEAM PRODUCED BY 26 MEV PROTONS ON BERYLLIUM
    GOODHEAD, DT
    BERRY, RJ
    BANCE, DA
    GRAY, P
    STEDEFORD, B
    PHYSICS IN MEDICINE AND BIOLOGY, 1978, 23 (01): : 144 - 148
  • [22] Study of microdosimetric parameters of mixed radiation fields produced by D-T neutron generators of different designs - a comparison
    Dawn, Sandipan
    Bakshi, A. K.
    Raja, Alagu
    Patel, Tarun
    Sarkar, P. S.
    Datta, D.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 944
  • [23] PHYSICAL CHARACTERISTICS OF NRL FAST-NEUTRON BEAM FOR RADIATION-THERAPY
    THEUS, RB
    BONDELID, RO
    ATTIX, FH
    AUGUST, LS
    SHAPIRO, P
    SURRATT, RE
    ROGERS, CC
    CANCER, 1974, 34 (01) : 17 - 32
  • [24] FAST-NEUTRON BEAM RADIATION-THERAPY IN THE UNITED-STATES
    GRIFFIN, TW
    LARAMORE, GE
    HUSSEY, DH
    HENDRICKSON, FR
    RODRIGUEZANTUNEZ, A
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1982, 8 (12): : 2165 - 2168
  • [25] PRIMARY SHIELDING FOR A FAST-NEUTRON BEAM TO BE USED FOR RADIATION-THERAPY
    BICHSEL, H
    EENMAA, J
    GLASS, G
    LEWELLEN, TK
    WILLIAMS, DL
    WOOTTON, P
    WYCKOFF, WG
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1972, 17 (12): : 1181 - 1181
  • [26] ANALYTICAL DESCRIPTION OF THE d(14)+Be NEUTRON BEAM SOURCE AT THE ESSEN FAST NEUTRON THERAPY FACILITY
    Morand, Josselin
    Hentschel, Reinhard
    Wittig, Andrea
    Moss, Raymond
    Hachem, Sabet
    Liu, Yuan-Hao
    Sauerwein, Wolfgang
    NUCLEAR TECHNOLOGY, 2009, 168 (02) : 456 - 461
  • [27] EARLY ASSESSMENT OF NORMAL TISSUE TOLERANCE OF FAST-NEUTRON BEAM RADIATION-THERAPY
    PARKER, RG
    BERRY, HC
    GERDES, AJ
    CANCER, 1976, 38 (03) : 1118 - 1123
  • [28] ACTIVATION OF THE MAJOR CONSTITUENTS OF TISSUE AND AIR BY A FAST-NEUTRON RADIATION-THERAPY BEAM
    TENHAKEN, RK
    AWSCHALOM, M
    ROSENBERG, I
    MEDICAL PHYSICS, 1983, 10 (05) : 636 - 641
  • [29] RADIATION SOURCES, BEAM QUALITY, DOSIMETRY AND SPECTROSCOPY IN NEUTRON-CAPTURE THERAPY - AN OVERVIEW
    KANDA, K
    STRAHLENTHERAPIE UND ONKOLOGIE, 1989, 165 (2-3): : 67 - 69
  • [30] EFFECT OF VARIATION IN THE ENERGY-SPECTRUM OF A CYCLOTRON-PRODUCED FAST-NEUTRON BEAM IN A PHANTOM RELEVANT TO ITS APPLICATION IN RADIOTHERAPY
    BONNETT, DE
    PARNELL, CJ
    BRITISH JOURNAL OF RADIOLOGY, 1982, 55 (649): : 48 - 55