Optimising diffusion-weighted imaging in the abdomen and pelvis: comparison of image quality between monopolar and bipolar single-shot spin-echo echo-planar sequences

被引:22
|
作者
Kyriazi, Stavroula [1 ,2 ,3 ]
Blackledge, Matthew [1 ,2 ,3 ]
Collins, David J. [1 ,2 ,3 ]
deSouza, Nandita M. [1 ,2 ,3 ]
机构
[1] Royal Marsden NHS Fdn Trust, CR UK, Sutton SM2 5PT, Surrey, England
[2] Royal Marsden NHS Fdn Trust, EPSRC Canc Imaging Ctr, Sutton SM2 5PT, Surrey, England
[3] Inst Canc Res, Sutton SM2 5PT, Surrey, England
关键词
Diffusion-weighted imaging DWI; Image quality; Artefact; Eddy currents; Distortion; EDDY-CURRENT ARTIFACTS; COEFFICIENT MEASUREMENTS; MRI; REDUCTION; GRADIENT;
D O I
10.1007/s00330-010-1826-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To compare geometric distortion, signal-to-noise ratio (SNR), apparent diffusion coefficient (ADC), efficacy of fat suppression and presence of artefact between monopolar (Stejskal and Tanner) and bipolar (twice-refocused, eddy-current-compensating) diffusion-weighted imaging (DWI) sequences in the abdomen and pelvis. A semiquantitative distortion index (DI) was derived from the subtraction images with b = 0 and 1,000 s/mm(2) in a phantom and compared between the two sequences. Seven subjects were imaged with both sequences using four b values (0, 600, 900 and 1,050 s/mm(2)) and SNR, ADC for different organs and fat-to-muscle signal ratio (FMR) were compared. Image quality was evaluated by two radiologists on a 5-point scale. DI was improved in the bipolar sequence, indicating less geometric distortion. SNR was significantly lower for all tissues and b values in the bipolar images compared with the monopolar (p < 0.05), whereas FMR was not statistically different. ADC in liver, kidney and sacrum was higher in the bipolar scheme compared to the monopolar (p < 0.03), whereas in muscle it was lower (p = 0.018). Image quality scores were higher for the bipolar sequence (p a parts per thousand currency signaEuro parts per thousand 0.025). Artefact reduction makes the bipolar DWI sequence preferable in abdominopelvic applications, although the trade-off in SNR may compromise ADC measurements in muscle.
引用
收藏
页码:2422 / 2431
页数:10
相关论文
共 50 条
  • [1] Optimising diffusion-weighted imaging in the abdomen and pelvis: comparison of image quality between monopolar and bipolar single-shot spin-echo echo-planar sequences
    Stavroula Kyriazi
    Matthew Blackledge
    David J. Collins
    Nandita M. deSouza
    European Radiology, 2010, 20 : 2422 - 2431
  • [2] Qualitative and quantitative comparison of image quality between single-shot echo-planar and interleaved multi-shot echo-planar diffusion-weighted imaging in female pelvis
    He An
    Xiaodong Ma
    Ziyi Pan
    Hua Guo
    Elaine Yuen Phin Lee
    European Radiology, 2020, 30 : 1876 - 1884
  • [3] Qualitative and quantitative comparison of image quality between single-shot echo-planar and interleaved multi-shot echo-planar diffusion-weighted imaging in female pelvis
    An, He
    Ma, Xiaodong
    Pan, Ziyi
    Guo, Hua
    Lee, Elaine Yuen Phin
    EUROPEAN RADIOLOGY, 2020, 30 (04) : 1876 - 1884
  • [4] Readout-segmented echo-planar imaging improves the image quality of diffusion-weighted MR imaging in rectal cancer: Comparison with single-shot echo-planar diffusion-weighted sequences
    Xia, Chun-chao
    Liu, Xi
    Peng, Wan-lin
    Li, Lei
    Zhang, Jin-ge
    Meng, Wen-jian
    Deng, Xiang-bing
    Zuo, Pan-li
    Li, Zhen-lin
    EUROPEAN JOURNAL OF RADIOLOGY, 2016, 85 (10) : 1818 - 1823
  • [5] Readout-segmented echo-planar imaging in diffusion-weighted imaging of the kidney: comparison with single-shot echo-planar imaging in image quality
    Chen-Jiang Wu
    Qing Wang
    Jing Zhang
    Xiao-Ning Wang
    Xi-Sheng Liu
    Yu-Dong Zhang
    Hai-Bin Shi
    Abdominal Radiology, 2016, 41 : 100 - 108
  • [6] Readout-segmented echo-planar imaging in diffusion-weighted imaging of the kidney: comparison with single-shot echo-planar imaging in image quality
    Wu, Chen-Jiang
    Wang, Qing
    Zhang, Jing
    Wang, Xiao-Ning
    Liu, Xi-Sheng
    Zhang, Yu-Dong
    Shi, Hai-Bin
    ABDOMINAL RADIOLOGY, 2016, 41 (01) : 100 - 108
  • [7] Characterization of focal hepatic lesions on diffusion-weighted MR imaging: Comparison between single-shot echo-planar imaging and single shot fast spin-echo sequence
    Ohgiya, Y
    Gokan, T
    Nobusawa, H
    Hirose, M
    Seino, N
    Munechika, H
    RADIOLOGY, 2001, 221 : 108 - 108
  • [8] Diffusion-weighted imaging of the brain: comparison of stimulated- and spin-echo echo-planar sequences
    Heiland, S
    Dietrich, O
    Sartor, K
    NEURORADIOLOGY, 2001, 43 (06) : 442 - 447
  • [9] Diffusion-weighted imaging of the brain: comparison of stimulated- and spin-echo echo-planar sequences
    S. Heiland
    O. Dietrich
    K. Sartor
    Neuroradiology, 2001, 43 : 442 - 447
  • [10] Evaluation of Thin-slice Coronal Single-shot Turbo Spin-echo Diffusion-weighted Imaging of the Hand: A Comparison with Conventional Echo-planar Diffusion-weighted Imaging
    Ogawa, Masaki
    Nakagawa, Motoo
    Arai, Nobuyuki
    Kan, Hirohito
    Ohba, Shota
    Shibata, Shunsuke
    Maki, Hiroyuki
    Shibamoto, Yuta
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2020, 19 (04) : 382 - 388