Comparison of different video laryngoscopes for emergency intubation in a standardized airway manikin with immobilized cervical spine by experienced anaesthetists. A randomized, controlled crossover trial

被引:54
|
作者
Wetsch, Wolfgang A. [1 ]
Spelten, Oliver [1 ]
Hellmich, Martin [2 ]
Carlitscheck, Martin [1 ]
Padosch, Stephan A. [1 ]
Lier, Heiko [1 ]
Boettiger, Bernd W. [1 ]
Hinkelbein, Jochen [1 ]
机构
[1] Univ Hosp Cologne, Dept Anaesthesiol & Intens Care Med, D-50937 Cologne, Germany
[2] Univ Cologne, Inst Med Stat Informat & Epidemiol, D-50931 Cologne, Germany
关键词
Intubation; Laryngoscopes; Difficult airway management; Training; IN-LINE STABILIZATION; TRACHEAL INTUBATION; MACINTOSH LARYNGOSCOPE; PENTAX AWS(R); ADVANCED PARAMEDICS; MANAGEMENT; GLIDESCOPE(R); AIRTRAQ(R); VIDEOLARYNGOSCOPE; COMPLICATIONS;
D O I
10.1016/j.resuscitation.2011.11.024
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: The aim of the present study was to evaluate whether different video laryngoscopes (VLs) facilitate endotracheal intubation (ETI) faster or more secure than conventional laryngoscopy in a manikin with immobilized cervical spine. Methods: After local ethics board approval, a standard airway manikin with cervical spine immobilization by means of a standard stiff collar was placed on a trauma stretcher. We compared times until glottic view, ETI, cuff block and first ventilation were achieved, and verified the endotracheal tube position, when using Macintosh laryngoscope, Glidescope Ranger, Storz C-MAC, Ambu Pentax AWS, Airtraq, and McGrath Series5 VLs in randomized order. Wilcoxon signed-rank test and McNemar's test were used for statistical analysis; p < 0.05 was considered as significant. Results: Twenty-three anaesthetists (mean age 32.1 +/- 4.9 years, mean experience in anaesthesia of 6.9 +/- 4.8 years) routinely involved in the management of multitrauma patients participated. The primary study end point, time to first effective ventilation, was achieved fastest when using Macintosh laryngoscope (21.0 +/- 7.6 s) and was significantly slower with all other devices (Airtraq 33.2 +/- 23.9 s, p = 0.002; Pentax AirwayScope 32.4 +/- 14.9 s, p = 0.001; Storz C-MAC 34.1 +/- 23.9 s, p < 0.001; McGrath Series5 101.7 perpendicular to 108.3 s, p < 0.001; Glidescope Ranger 46.3 perpendicular to 59.1 s, p = 0.001). Overall success rates were highest when using Macintosh, Airtraq and Storz C-MAC devices (100%), and were lower in Ambu Pentax AWS and Glidescope Ranger (87%, p = 0.5) and in McGrath Series5 device (72.2%, p = 0.063). Conclusion: When used by experienced anaesthesiologists, video laryngoscopes did not facilitate endotracheal intubation in this model with an immobilized cervical spine in a faster or more secure way than conventional laryngoscopy. However, data was gathered in a standardized model and further studies in real trauma patients are desirable to verify our findings. (C) 2011 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:740 / 745
页数:6
相关论文
共 36 条
  • [1] Comparison of the ETView Single Lumen and Macintosh laryngoscopes for endotracheal intubation in an airway manikin with immobilized cervical spine by novice paramedics A randomized crossover manikin trial
    Gawlowski, Pawel
    Smereka, Jacek
    Madziala, Marcin
    Cohen, Barak
    Ruetzler, Kurt
    Szarpak, Lukasz
    MEDICINE, 2017, 96 (16)
  • [2] Comparison of the VivaSight single lumen endotracheal tube and the Macintosh laryngoscope for emergency intubation by experienced paramedics in a standardized airway manikin with restricted access: a randomized, crossover trial
    Truszewski, Zenon
    Szarpak, Lukasz
    Smereka, Jacek
    Kurowski, Andrzej
    Evrin, Togay
    Czyzewski, Lukasz
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2016, 34 (05): : 929 - 930
  • [3] Comparison of a New Video Intubation Stylet and McGrath® MAC Video Laryngoscope for Intubation in an Airway Manikin with Normal Airway and Cervical Spine Immobilization Scenarios by Novice Personnel: A Randomized Crossover Study
    Park, Jin-Woo
    An, Sungmin
    Park, Seongjoo
    Nahm, Francis Sahngun
    Han, Sung-Hee
    Kim, Jin-Hee
    BIOMED RESEARCH INTERNATIONAL, 2021, 2021
  • [4] Comparison of blind intubation via supraglottic airway devices versus standard intubation during different airway emergency scenarios in inexperienced hand Randomized, crossover manikin trial
    Bielski, Andrzej
    Rivas, Eva
    Ruetzler, Kurt
    Smereka, Jacek
    Puslecki, Mateusz
    Dabrowski, Marek
    Ladny, Jerzy R.
    Frass, Michael
    Robak, Oliver
    Evrin, Togay
    Szarpak, Lukasz
    MEDICINE, 2018, 97 (40)
  • [5] Comparison of Direct and Video Laryngoscopes during Different Airway Scenarios Performed by Experienced Paramedics: A Randomized Cross-Over Manikin Study
    Ruetzler, Kurt
    Szarpak, Lukasz
    Smereka, Jacek
    Dabrowski, Marek
    Bialka, Szymon
    Mosteller, Lauretta
    Szarpak, Agnieszka
    Ludwin, Kobi
    Wojewodzka-Zelezniakowicz, Marzena
    Ladny, Jerzy Robert
    BIOMED RESEARCH INTERNATIONAL, 2020, 2020
  • [6] A Comparison of Different Video Laryngoscopes for Prehospital Emergency Intubation: a Prospective, Randomized Multicenter Study
    Cavus, Erol
    Janssen, Sebastian
    Reifferscheid, Florian
    Caliebe, Amke
    Callies, Andreas
    von der Heyden, Martin
    Knacke, Peer G.
    Doerges, Volker
    NOTARZT, 2019, 35 (01): : 23 - 31
  • [7] Comparison of ETView SL, Airtraq, and Macintosh laryngoscopes for face-to-face tracheal intubation: a randomized crossover manikin trial
    Madziala, Agnieszka
    Majer, Jolanta
    Madziala, Marcin
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2016, 34 (09): : 1893 - 1894
  • [8] Comparison of the Macintosh laryngoscope and blind intubation via the iGEL for Intubation With C-spine immobilization: A Randomized, crossover, manikin trial
    Gawlowski, Pawel
    Smereka, Jacek
    Madziala, Marcin
    Szarpak, Lukasz
    Frass, Michael
    Robak, Oliver
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2017, 35 (03): : 484 - 487
  • [9] Comparison of McGrath, Pentax, and Macintosh laryngoscope in normal and cervical immobilized manikin by novices: a randomized crossover trial
    In Kyong Yi
    Hyun Jeong Kwak
    Kyung Cheon Lee
    Ji Hyea Lee
    Sang Kee Min
    Jong Yeop Kim
    European Journal of Medical Research, 25
  • [10] Comparison of McGrath, Pentax, and Macintosh laryngoscope in normal and cervical immobilized manikin by novices: a randomized crossover trial
    Yi, In Kyong
    Kwak, Hyun Jeong
    Lee, Kyung Cheon
    Lee, Ji Hyea
    Min, Sang Kee
    Kim, Jong Yeop
    EUROPEAN JOURNAL OF MEDICAL RESEARCH, 2020, 25 (01)