Comparison of different video laryngoscopes for emergency intubation in a standardized airway manikin with immobilized cervical spine by experienced anaesthetists. A randomized, controlled crossover trial

被引:54
|
作者
Wetsch, Wolfgang A. [1 ]
Spelten, Oliver [1 ]
Hellmich, Martin [2 ]
Carlitscheck, Martin [1 ]
Padosch, Stephan A. [1 ]
Lier, Heiko [1 ]
Boettiger, Bernd W. [1 ]
Hinkelbein, Jochen [1 ]
机构
[1] Univ Hosp Cologne, Dept Anaesthesiol & Intens Care Med, D-50937 Cologne, Germany
[2] Univ Cologne, Inst Med Stat Informat & Epidemiol, D-50931 Cologne, Germany
关键词
Intubation; Laryngoscopes; Difficult airway management; Training; IN-LINE STABILIZATION; TRACHEAL INTUBATION; MACINTOSH LARYNGOSCOPE; PENTAX AWS(R); ADVANCED PARAMEDICS; MANAGEMENT; GLIDESCOPE(R); AIRTRAQ(R); VIDEOLARYNGOSCOPE; COMPLICATIONS;
D O I
10.1016/j.resuscitation.2011.11.024
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: The aim of the present study was to evaluate whether different video laryngoscopes (VLs) facilitate endotracheal intubation (ETI) faster or more secure than conventional laryngoscopy in a manikin with immobilized cervical spine. Methods: After local ethics board approval, a standard airway manikin with cervical spine immobilization by means of a standard stiff collar was placed on a trauma stretcher. We compared times until glottic view, ETI, cuff block and first ventilation were achieved, and verified the endotracheal tube position, when using Macintosh laryngoscope, Glidescope Ranger, Storz C-MAC, Ambu Pentax AWS, Airtraq, and McGrath Series5 VLs in randomized order. Wilcoxon signed-rank test and McNemar's test were used for statistical analysis; p < 0.05 was considered as significant. Results: Twenty-three anaesthetists (mean age 32.1 +/- 4.9 years, mean experience in anaesthesia of 6.9 +/- 4.8 years) routinely involved in the management of multitrauma patients participated. The primary study end point, time to first effective ventilation, was achieved fastest when using Macintosh laryngoscope (21.0 +/- 7.6 s) and was significantly slower with all other devices (Airtraq 33.2 +/- 23.9 s, p = 0.002; Pentax AirwayScope 32.4 +/- 14.9 s, p = 0.001; Storz C-MAC 34.1 +/- 23.9 s, p < 0.001; McGrath Series5 101.7 perpendicular to 108.3 s, p < 0.001; Glidescope Ranger 46.3 perpendicular to 59.1 s, p = 0.001). Overall success rates were highest when using Macintosh, Airtraq and Storz C-MAC devices (100%), and were lower in Ambu Pentax AWS and Glidescope Ranger (87%, p = 0.5) and in McGrath Series5 device (72.2%, p = 0.063). Conclusion: When used by experienced anaesthesiologists, video laryngoscopes did not facilitate endotracheal intubation in this model with an immobilized cervical spine in a faster or more secure way than conventional laryngoscopy. However, data was gathered in a standardized model and further studies in real trauma patients are desirable to verify our findings. (C) 2011 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:740 / 745
页数:6
相关论文
共 36 条
  • [31] Comparison of the paediatric blade of the Pentax-AWS and Ovassapian airway in fibreoptic tracheal intubation in patients with limited mouth opening and cervical spine immobilization by a semi-rigid neck collar: a randomized controlled trial
    Kim, D. H.
    Yoo, J. Y.
    Ha, S. Y.
    Chae, Y. J.
    BRITISH JOURNAL OF ANAESTHESIA, 2017, 119 (05) : 993 - 999
  • [32] Comparison between use of single lightwand and video laryngoscope-guided lightwand for tracheal intubation in simulated cervical spine-immobilized patients: a single-blind randomized study
    Kim, Ha Yeon
    Kum, Eun Jung
    Yoon, Hei Jin
    Ko, Byungwoong
    Choi, Seung Yeon
    Koo, Bon-Nyeo
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2019, 47 (11) : 5632 - 5642
  • [33] Comparison between C-MAC D-blade video laryngoscope and McCoy laryngoscope for nasotracheal intubation in traumatic cervical spine surgery - A randomised controlled trial
    Singh, Swati
    Kumar, Amit
    Kumar, Brajesh
    Singh, Swarnika
    INDIAN JOURNAL OF ANAESTHESIA, 2023, 67 (09) : 821 - 824
  • [34] Comparison of Glidescope(R)Go™, King Vision™, Dahlhausen VL, I-View™and Macintosh laryngoscope use during difficult airway management simulation by experienced and inexperienced emergency medical staff: A randomized crossover manikin study
    Moritz, Andreas
    Leonhardt, Veronika
    Prottengeier, Johannes
    Birkholz, Torsten
    Schmidt, Joachim
    Irouschek, Andrea
    PLOS ONE, 2020, 15 (07):
  • [35] Intubating Laryngeal Mask Airway-assisted Flexible Bronchoscopic Intubation Is Associated With Reduced Cervical Spine Motion When Compared With C-MAC Video Laryngoscopy-guided Intubation: A Prospective Randomized Cross Over Trial
    Swain, Amlan
    Bhagat, Hemant
    Gupta, Vivek
    Salunke, Pravin
    Panda, Nidhi B.
    Sahu, Seelora
    JOURNAL OF NEUROSURGICAL ANESTHESIOLOGY, 2020, 32 (03) : 242 - 248
  • [36] Comparison of the C-MAC video laryngoscope size 2 Macintosh blade with size 2 C-MAC D-Blade for laryngoscopy and endotracheal intubation in children with simulated cervical spine injury: A prospective randomized crossover study
    Sinha, Renu
    Ray, Bikash Ranjan
    Sharma, Ankur
    Pandey, Ravinder Kumar
    Punj, Jyotsna
    Darlong, Vanlalnghaka
    Trikha, Anjan
    JOURNAL OF ANAESTHESIOLOGY CLINICAL PHARMACOLOGY, 2019, 35 (04) : 509 - 514