Early Aortic Transcatheter Heart Valve Thrombosis Diagnostic Value of Contrast-Enhanced Multidetector Computed Tomography

被引:167
|
作者
Leetmaa, Tina [1 ]
Hansson, Nicolaj C. [1 ]
Leipsic, Jonathon [3 ,4 ]
Jensen, Kaare [1 ]
Poulsen, Steen H. [1 ]
Andersen, Henning R. [1 ]
Jensen, Jesper M. [1 ]
Webb, John [3 ,4 ]
Blanke, Philipp [3 ,4 ]
Tang, Mariann [2 ]
Norgaard, Bjarne L. [1 ]
机构
[1] Aarhus Univ Hosp Skejby, Dept Cardiol, Aarhus, Denmark
[2] Aarhus Univ Hosp Skejby, Dept Cardiothorac & Vasc Surg, Aarhus, Denmark
[3] Univ British Columbia, St Pauls Hosp, Div Cardiol, Vancouver, BC V5Z 1M9, Canada
[4] Univ British Columbia, Dept Radiol, St Pauls Hosp, Vancouver, BC, Canada
关键词
aortic valve stenosis; multislice computed tomography; thrombosis; transcatheter aortic valve replacement; IMPLANTATION; REPLACEMENT; POSITION; CT; BIOPROSTHESES; REGURGITATION; THROMBOLYSIS; DYSFUNCTION; RESTENOSIS; STENOSIS;
D O I
10.1161/CIRCINTERVENTIONS.114.001596
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-Early stent valve thrombosis after transcatheter aortic valve implantation (TAVI) is a rare complication, which is diagnosed based on the appearance of clinical symptoms of heart failure and echocardiographic findings. After TAVI, transthoracic echocardiography is performed to assess transcatheter heart valve (THV) function. However, preliminary reports indicate the potential additive clinical value of multidetector computed tomography (MDCT) for the diagnosis of THV thrombosis. We sought to determine the value of MDCT for the diagnosis of THV thrombosis and the frequency of this complication after balloon-expandable TAVI. Methods and Results-MDCT was performed in 140 patients within 1 to 3 months after TAVI with the Edwards Sapien XT THV to assess the presence of THV thrombosis and THV stent geometry. Post-TAVI MDCT identified THV thrombosis in 5 patients (4%). Of note, 4 of these patients were asymptomatic and had a normal transthoracic echocardiographic examination without signs of thrombus formation or flow obstruction. In patients with THV thrombosis, a left ventricular ejection fraction of <35% was present in 3 (60%), whereas 2 (40%) did not receive standard post-TAVI dual-antiplatelet therapy. Neither THV underexpansion nor THV noncircularity was detected in patients with THV thrombosis. Conclusions-Post-TAVI MDCT is a valuable tool for the diagnosis of THV thrombosis, and this complication seems to be more common than previously anticipated. Larger studies are required to identify specific risk factors of THV thrombosis.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] OPTIMIZATION OF CONTRAST-ENHANCED MULTIDETECTOR ABDOMINAL COMPUTED TOMOGRAPHY IN SEDATED CANINE PATIENTS
    Fields, Erica L.
    Robertson, Ian D.
    Brown, James C., Jr.
    VETERINARY RADIOLOGY & ULTRASOUND, 2012, 53 (05) : 507 - 512
  • [32] The Use of Contrast-Enhanced Multidetector Computed Tomography Imaging in Advanced Abdominal Pregnancy
    Chan, Adrian
    Rampersad, Fidel S.
    Ramsundar, Ashton
    Boodram, Anil
    Rampersad, Robbie
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (02)
  • [33] Diagnostic utility of contrast-enhanced computed tomography for ectopic pregnancy
    Iizuka, Takashi
    Yoshida, Kotaro
    Yamazaki, Rena
    Matsuoka, Ayumi
    Fujiwara, Hiroshi
    INTERNATIONAL JOURNAL OF GYNECOLOGY & OBSTETRICS, 2024, 167 (01) : 395 - 402
  • [34] Diagnostic accuracy of 64-slice multidetector computed tomography for the evaluation of aortic root in patients selected for transcatheter aortic valve implantation
    Pontone, G.
    Andreini, D.
    Bertella, E.
    Mushtaq, S.
    Annoni, A. D.
    Tamborini, G.
    Fusari, M.
    Ballerini, G.
    Bartorelli, A. L.
    Pepi, M.
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2011, 13 (0A) : A4 - A4
  • [35] Diagnostic accuracy of 64-slice multidetector computed tomography for the evaluation of aortic root in patients selected for transcatheter aortic valve implantation
    Pontone, G.
    Andreini, D.
    Bertella, E.
    Mushtaq, S.
    Annoni, A. D.
    Tamborini, G.
    Fusari, M.
    Ballerini, G.
    Bartorelli, A. L.
    Pepi, M.
    EUROPEAN HEART JOURNAL, 2010, 31 : 292 - 292
  • [36] Early Transcatheter Aortic Valve Thrombosis
    Greason, Kevin L.
    Mathew, Verghese
    Sarano, Maurice E.
    Maleszewski, Joseph J.
    Suri, Rakesh M.
    Rihal, Charanjit S.
    JOURNAL OF CARDIAC SURGERY, 2013, 28 (03) : 264 - 266
  • [37] Early transcatheter aortic valve thrombosis
    Gil Ramirez, Andreina J.
    Burgos, Lucrecia
    Costabel, Juan Pablo
    Castro, Florencia
    REVISTA DE LA FEDERACION ARGENTINA DE CARDIOLOGIA, 2019, 48 (01): : 35 - 37
  • [38] Assessing diagnostic value of contrast-enhanced ultrasound and contrast-enhanced computed tomography in detecting small hepatocellular carcinoma A meta-analysis
    Huang, Jiasheng
    Chen, Wei
    Yao, Shanwen
    MEDICINE, 2017, 96 (30)
  • [39] An evaluation of the clinical diagnostic value of contrast-enhanced ultrasound combined with contrast-enhanced computed tomography in space-occupying lesions of the kidney
    Tian, Wen
    Lu, Jianbo
    Jiao, Dan
    Cong, Zhibin
    ONCOTARGETS AND THERAPY, 2017, 10 : 3493 - 3499
  • [40] Prognostic value of contrast-enhanced computed tomography in acute pancreatitis
    Jakchairoongruang, Ketsuda
    Arjhansiri, Kiat
    ASIAN BIOMEDICINE, 2013, 7 (03) : 357 - 364