Early Aortic Transcatheter Heart Valve Thrombosis Diagnostic Value of Contrast-Enhanced Multidetector Computed Tomography

被引:167
|
作者
Leetmaa, Tina [1 ]
Hansson, Nicolaj C. [1 ]
Leipsic, Jonathon [3 ,4 ]
Jensen, Kaare [1 ]
Poulsen, Steen H. [1 ]
Andersen, Henning R. [1 ]
Jensen, Jesper M. [1 ]
Webb, John [3 ,4 ]
Blanke, Philipp [3 ,4 ]
Tang, Mariann [2 ]
Norgaard, Bjarne L. [1 ]
机构
[1] Aarhus Univ Hosp Skejby, Dept Cardiol, Aarhus, Denmark
[2] Aarhus Univ Hosp Skejby, Dept Cardiothorac & Vasc Surg, Aarhus, Denmark
[3] Univ British Columbia, St Pauls Hosp, Div Cardiol, Vancouver, BC V5Z 1M9, Canada
[4] Univ British Columbia, Dept Radiol, St Pauls Hosp, Vancouver, BC, Canada
关键词
aortic valve stenosis; multislice computed tomography; thrombosis; transcatheter aortic valve replacement; IMPLANTATION; REPLACEMENT; POSITION; CT; BIOPROSTHESES; REGURGITATION; THROMBOLYSIS; DYSFUNCTION; RESTENOSIS; STENOSIS;
D O I
10.1161/CIRCINTERVENTIONS.114.001596
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-Early stent valve thrombosis after transcatheter aortic valve implantation (TAVI) is a rare complication, which is diagnosed based on the appearance of clinical symptoms of heart failure and echocardiographic findings. After TAVI, transthoracic echocardiography is performed to assess transcatheter heart valve (THV) function. However, preliminary reports indicate the potential additive clinical value of multidetector computed tomography (MDCT) for the diagnosis of THV thrombosis. We sought to determine the value of MDCT for the diagnosis of THV thrombosis and the frequency of this complication after balloon-expandable TAVI. Methods and Results-MDCT was performed in 140 patients within 1 to 3 months after TAVI with the Edwards Sapien XT THV to assess the presence of THV thrombosis and THV stent geometry. Post-TAVI MDCT identified THV thrombosis in 5 patients (4%). Of note, 4 of these patients were asymptomatic and had a normal transthoracic echocardiographic examination without signs of thrombus formation or flow obstruction. In patients with THV thrombosis, a left ventricular ejection fraction of <35% was present in 3 (60%), whereas 2 (40%) did not receive standard post-TAVI dual-antiplatelet therapy. Neither THV underexpansion nor THV noncircularity was detected in patients with THV thrombosis. Conclusions-Post-TAVI MDCT is a valuable tool for the diagnosis of THV thrombosis, and this complication seems to be more common than previously anticipated. Larger studies are required to identify specific risk factors of THV thrombosis.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Diagnostic value of contrast-enhanced computed tomography for diagnosing the intraductal component of breast cancer
    Sadako Akashi-Tanaka
    Takashi Fukutomi
    Kunihisa Miyakawa
    Nachiko Uchiyama
    Hitoshi Tsuda
    Breast Cancer Research and Treatment, 1998, 49 : 79 - 86
  • [22] Diagnostic value of contrast-enhanced computed tomography for diagnosing the intraductal component of breast cancer
    Akashi-Tanaka, S
    Fukutomi, T
    10TH INTERNATIONAL CONGRESS ON SENOLOGY - BREAST DISEASES OF THE SENOLOGIC INTERNATIONAL SOCIETY, 1998, : 587 - 591
  • [23] Diagnostic value of contrast-enhanced computed tomography for diagnosing the intraductal component of breast cancer
    Akashi-Tanaka, S
    Fukutomi, T
    Miyakawa, K
    Uchiyama, N
    Tsuda, H
    BREAST CANCER RESEARCH AND TREATMENT, 1998, 49 (01) : 79 - 86
  • [24] Multidetector computed tomography in Transcatheter aortic valve implantation. Where we stand
    Al-Hassan, D.
    Blanke, P.
    Leipsic, J.
    MINERVA CARDIOANGIOLOGICA, 2013, 61 (04): : 407 - 427
  • [25] Diagnostic Efficacy of Dynamic Maneuver in Contrast-Enhanced Computed Tomography Compared With Conventional Contrast-Enhanced Computed Tomography in Imaging the Neck Region
    Sanjaykanth, B.
    Sam, Ajina
    Gunasekaran, Dhivya
    Muralidharan, Yuvaraj
    Natarajan, Paarthipan
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (07)
  • [26] Diagnostic accuracy of multidetector computed tomography coronary angiography in 325 consecutive patients referred for transcatheter aortic valve replacement
    Andreini, Daniele
    Pontone, Gianluca
    Mushtaq, Saima
    Bartorelli, Antonio L.
    Ballerini, Giovanni
    Bertella, Erika
    Segurini, Chiara
    Conte, Edoardo
    Annoni, Andrea
    Baggiano, Andrea
    Formenti, Alberto
    Fusini, Laura
    Tamborini, Gloria
    Alamanni, Francesco
    Fiorentini, Cesare
    Pepi, Mauro
    AMERICAN HEART JOURNAL, 2014, 168 (03) : 332 - 339
  • [27] Congenital anomalies of the coronary arteries: imaging with contrast-enhanced, multidetector computed tomography
    Rainer Schmitt
    Steffen Froehner
    Juergen Brunn
    Matthias Wagner
    Horst Brunner
    Oleg Cherevatyy
    Frank Gietzen
    Georgios Christopoulos
    Sebastian Kerber
    Franz Fellner
    European Radiology, 2005, 15 : 1110 - 1121
  • [28] Studying the complications of bariatric surgery with intravenous contrast-enhanced multidetector computed tomography
    Morandeira, C.
    Barcena, M. V.
    Bilbao, A.
    Perez, M.
    Ibanez, A. M.
    Isusi, M.
    Lecumberri, G.
    RADIOLOGIA, 2018, 60 (02): : 143 - 151
  • [29] Contrast-enhanced multidetector computed tomography: A new prognosticator in acute pulmonary embolism?
    Barra, Sergio
    Providencia, Rui
    Paiva, Luis
    REVISTA PORTUGUESA DE CARDIOLOGIA, 2013, 32 (10) : 839 - 840
  • [30] Congenital anomalies of the coronary arteries: imaging with contrast-enhanced, multidetector computed tomography
    Schmitt, R
    Froehner, S
    Brunn, J
    Wagner, M
    Brunner, H
    Cherevatyy, O
    Gietzen, F
    Christopoulos, G
    Kerber, S
    Fellner, F
    EUROPEAN RADIOLOGY, 2005, 15 (06) : 1110 - 1121