Preliminary study on the orbit cross-calibration of CMODIS by SeaWiFS

被引:8
|
作者
Pan, DL [1 ]
He, XQ [1 ]
Man, TM [1 ]
机构
[1] SOA, Key Lab Ocean Dynam Proc & Satellite Oceanog, Hangzhou 310012, Peoples R China
关键词
CMODIS; SeaWiFS; cross-calibration;
D O I
10.1080/10020070312331344350
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
dChina launched its third spaceship SZ-3 in March, 2002 on which the main remote sensor is the Chinese moderate imaging spectra radiometer (CMODIS). In this paper the properties of CMODIS are firstly introduced briefly. Then, the theory and algorithm of cross-calibration for CMODIS ocean color channels by the sea-viewing wide field-of-view sensor (SeaWiFS) data are discussed in detail. The total radiance (TOA) of four quasi-synchronized crossing ocean areas simulated by SeaWiFS and measured by CMODIS are compared and the calibration coefficients are derived from the relationship between them. Finally, the in-situ water leaving radiance data are used to validate the calibration results. The results show that the cross-calibration method could provide reasonable precision for ocean color measurement.
引用
收藏
页码:745 / 749
页数:5
相关论文
共 50 条
  • [31] Cross-calibration of cluster mass observables
    Cunha, Carlos
    [J]. PHYSICAL REVIEW D, 2009, 79 (06):
  • [32] Online Cross-Calibration of Camera and LIDAR
    Blaga, Bianca-Cerasela-Zelia
    Nedevschi, Sergiu
    [J]. 2017 13TH IEEE INTERNATIONAL CONFERENCE ON INTELLIGENT COMPUTER COMMUNICATION AND PROCESSING (ICCP), 2017, : 295 - 301
  • [33] Static and mobile DXA scanner in-vivo cross-calibration study
    Griffin, J. G. L.
    Knapp, K. M.
    Pearce, G.
    [J]. RADIOGRAPHY, 2013, 19 (01) : 7 - 10
  • [34] Assessment of Spectral, Misregistration, and Spatial Uncertainties Inherent in the Cross-Calibration Study
    Chander, Gyanesh
    Helder, Dennis L.
    Aaron, David
    Mishra, Nischal
    Shrestha, Alok K.
    [J]. IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2013, 51 (03): : 1282 - 1296
  • [35] Universal cross-calibration of bone mineral density
    Hui, SL
    Lu, Y
    Genant, HK
    Glueer, CC
    [J]. JOURNAL OF BONE AND MINERAL RESEARCH, 1996, 11 : S602 - S602
  • [36] Cross-calibration of two small footprint sensors
    GustafsonBold, CL
    Thome, KJ
    [J]. IGARSS '96 - 1996 INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM: REMOTE SENSING FOR A SUSTAINABLE FUTURE, VOLS I - IV, 1996, : 1283 - 1285
  • [37] The On-Orbit Calibration of SeaWiFS: Functional Fits to the Lunar Time Series
    Eplee, Robert E., Jr.
    Meister, Gerhard
    Patt, Frederick S.
    McClain, Charles R.
    [J]. EARTH OBSERVING SYSTEMS XIII, 2008, 7081
  • [38] Uncertainty analysis in cross-calibration and optimization calculation of calibration coefficients
    Gao Shuai
    Li Yuan
    Bai Ting-zhu
    Zhang Yu-xiang
    Zheng Xiao-bing
    [J]. CHINESE OPTICS, 2020, 13 (03): : 568 - 576
  • [39] Radiometric Variations of On-Orbit FORMOSAT-5 RSI from Vicarious and Cross-Calibration Measurements
    Lin, Tang-Huang
    Chang, Jui-Chung
    Hsu, Kuo-Hsien
    Lee, Yun-Shan
    Zeng, Sheng-Kai
    Liu, Gin-Rong
    Tsai, Fu-An
    Chan, Hai-Po
    [J]. REMOTE SENSING, 2019, 11 (22)
  • [40] Total body potassium in healthy Italians and Americans - A cross-calibration study
    De Lorenzo, A
    Andreoli, A
    Puija, A
    Wang, J
    Pierson, RN
    [J]. IN VIVO BODY COMPOSITION STUDIES, 2000, 904 : 366 - 368