A quantum dot-based lateral flow immunoassay for the sensitive detection of human heart fatty acid binding protein (hFABP) in human serum

被引:42
|
作者
Savin, Mihaela [1 ,2 ]
Mihailescu, Carmen-Marinela [3 ]
Matei, Iulia [4 ,5 ]
Stan, Dana [2 ]
Moldovan, Carmen Aura [6 ]
Ion, Marian [6 ]
Baciu, Ion [1 ]
机构
[1] Univ Bucharest, Fac Chem, Regina Elisabeta Bd 4-12, Bucharest, Romania
[2] Telemedica, Jean Louis Calderonno 28, Bucharest, Romania
[3] DDS Diagnost, Vatra Luminoasa 45, Bucharest 031563, Romania
[4] Romanian Acad, Ilie Murgulescu Inst Phys Chem, 202 Splaiul Independentei, Bucharest 060021, Romania
[5] Univ Bucharest, Fac Chem, Dept Phys Chem, Bd Regina Elisabeta 4-12, Bucharest, Romania
[6] Natl Inst R&D Microtechnol IMT Bucharest, 126 A,Erou Iancu Nicolae St, Bucharest, Romania
关键词
Lateral flow immuno assay; H-FABP; Acute myocardial infarction; Quantum dots; Fluorescence detection; ACUTE MYOCARDIAL-INFARCTION; H-FABP; CDTE; BIOSENSOR;
D O I
10.1016/j.talanta.2017.10.045
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We describe the preparation and validation of a novel lateral flow immunoassay test for the detection of human heart fatty acid binding protein (hFABP). Water-soluble CdTe quantum dots (QDs) were selected as the fluorescent label and were linked covalently to anti-hFABP antibodies. Upon conjugation, the secondary structure of the anti-hFABP was preserved and the fluorescence quantum yield of the CdTe QDs increased. The labelled antibodies were transferred to the immunoassay test strip and the antigen-antibody reaction was successfully performed. This evidenced the preserved antibody activity of QD-labelled anti-hFABP towards hFABP, and provided a rapid means for the quantitation of hFABP in human serum within the range of 0-160 ng . ml(-1), with a much lower detection limit of 221 pg.ml(-1) compared with other rapid tests based on lateral flow immunoassays. This new immunoassay test has been successfully used for the early detection of acute myocardial infarction.
引用
收藏
页码:910 / 915
页数:6
相关论文
共 50 条
  • [1] Quantum dot-based lateral flow immunoassay for detection of chloramphenicol in milk
    Anna N. Berlina
    Nadezhda A. Taranova
    Anatoly V. Zherdev
    Yuri Y. Vengerov
    Boris B. Dzantiev
    Analytical and Bioanalytical Chemistry, 2013, 405 : 4997 - 5000
  • [2] Quantum dot-based lateral flow immunoassay for detection of chloramphenicol in milk
    Berlina, Anna N.
    Taranova, Nadezhda A.
    Zherdev, Anatoly V.
    Vengerov, Yuri Y.
    Dzantiev, Boris B.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2013, 405 (14) : 4997 - 5000
  • [3] Development of Quantum Dot-Based Lateral Flow Immunoassay System for Rapid Quantitative Detection of Human Chorionic Gonadotropin
    Yang Qiu-Hua
    Wang Xin
    Yang Jiu-Min
    Li Xue
    Song Tao
    Gong Xiao-Qun
    Zhang Bing-Bo
    Chang Jin
    PROGRESS IN BIOCHEMISTRY AND BIOPHYSICS, 2014, 41 (05) : 497 - 507
  • [4] Rapid lateral-flow immunoassay for the quantum dot-based detection of puerarin
    Qu, Huihua
    Zhang, Yue
    Qu, Baoping
    Kong, Hui
    Qin, Gaofeng
    Liu, Shuchen
    Cheng, Jinjun
    Wang, Qingguo
    Zhao, Yan
    BIOSENSORS & BIOELECTRONICS, 2016, 81 : 358 - 362
  • [5] A New Quantum Dot-Based Lateral Flow Immunoassay for the Rapid Detection of Influenza Viruses
    Kim, Soo-Kyung
    Sung, Heungsup
    Hwang, Sang-Hyun
    Kim, Mi-Na
    BIOCHIP JOURNAL, 2022, 16 (02) : 175 - 182
  • [6] A New Quantum Dot-Based Lateral Flow Immunoassay for the Rapid Detection of Influenza Viruses
    Soo-Kyung Kim
    Heungsup Sung
    Sang-Hyun Hwang
    Mi-Na Kim
    BioChip Journal, 2022, 16 : 175 - 182
  • [7] Development of carbon quantum dot-based lateral flow immunoassay for sensitive detection of aflatoxin M1 in milk
    Singh, Harpreet
    Singh, Shalini
    Bhardwaj, Sanjeev K.
    Kaur, Gurjeet
    Khatri, Madhu
    Deep, Akash
    Bhardwaj, Neha
    FOOD CHEMISTRY, 2022, 393
  • [8] Simple and sensitive progesterone detection in human serum using a CdSe/ZnS quantum dot-based direct binding assay
    Oh, Sung-Duk
    Duong, Hong Dinh
    Rhee, Jong Il
    ANALYTICAL BIOCHEMISTRY, 2015, 483 : 54 - 61
  • [9] Quantum Dot-Based Aptasensor for Sensitive Protein Detection
    Shin, Seonmi
    Kim, Yea Seul
    Kang, Ho-Jung
    Hah, Sang Soo
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2010, 31 (07): : 2091 - 2093
  • [10] A quantum dot-based optical immunosensor for human serum albumin detection
    Tu, Meng-Che
    Chang, Yun-Tzu
    Kang, Yu-Ting
    Chang, Hwan-You
    Chang, Pin
    Yew, Tri-Rung
    BIOSENSORS & BIOELECTRONICS, 2012, 34 (01): : 286 - 290