Development and Validation of Hematocrit Level Measurement in Dried Blood Spots Using Near-Infrared Spectroscopy

被引:18
|
作者
van de Velde, Daan [1 ]
van der Graaf, Jordy L. [1 ]
Boussaidi, Mariam [1 ]
Huisman, Ruud [1 ]
Hesselink, Dennis A. [2 ]
Russcher, Henk [3 ]
Kooij-Egas, Annelies C. [4 ]
van Maarseveen, Erik [4 ]
de Winter, Brenda C. M. [1 ]
机构
[1] Erasmus MC, Dept Hosp Pharm, Wytemaweg 80,POB 2040, NL-3015 CN Rotterdam, Netherlands
[2] Erasmus MC, Div Nephrol & Transplantat, Dept Internal Med, Rotterdam, Netherlands
[3] Erasmus MC, Dept Clin Chem, Univ Med Ctr Rotterdam, Rotterdam, Netherlands
[4] Univ Med Ctr Utrecht, Dept Hosp Pharm, Utrecht, Netherlands
关键词
PLS; spectroscopy; near-infrared; hematocrit; dried blood spot; PREDICTION; TACROLIMUS; LIPEMIA; HEMOLYSIS; ICTERUS;
D O I
10.1097/FTD.0000000000000834
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Dried blood spots (DBSs) have gained recent popularity as a sampling method for therapeutic drug monitoring. For patients, DBS sampling has several advantages over venous blood sampling. However, technical issues primarily influenced by hematocrit levels, interfere with the implementation of this method in daily clinical practice. The results of concentration measurements of drugs that are influenced by hematocrit should be corrected for hematocrit levels. In this article, we developed a fast, nondestructive, near-infrared (NIR)-based method for measuring the hematocrit in DBSs. Method: Using a partial least squares algorithm, an NIR-based quantification method was developed for measuring hematocrit levels of 0.19-0.49 L/L. Residual venous blood of 522 patients was used to build this partial least squares model. The validity of the method was evaluated using 40 patient samples. DBSs were created by adding a small amount (50 mu L) of blood on a Whatman filter paper and drying for 24 hours in a desiccator cabinet. The robustness was evaluated by measuring 24 additional samples with a high hemolysis, icterus, and lipemia (HIL) index. The hematocrit values obtained using a Sysmex XN hemocytometry analyzer were used as reference. Results: The difference between hematocrit measurements obtained with NIR spectroscopy and a hemocytometry analyzer was <15% for the 40 samples. The accuracy (<= 9%) and precision (<= 7%) for all the quality control samples were within the acceptance criteria of <15%. The intraassay and interassay coefficient of variability was <= 3% and <= 6%, respectively, for the different quality control levels. There were no deviations in the measurements for the samples with high HIL indices. The stability of hematocrit in DBS was up to 14 days for all levels. Conclusions: We developed and validated a hematocrit model using NIR spectroscopy. This nondestructive, accurate, and reproducible method has a short analysis time (51 seconds), and can be used to analyze DBS samples stored for up to 2 weeks in a desiccator cabinet.
引用
收藏
页码:351 / 357
页数:7
相关论文
共 50 条
  • [41] Measurement of cerebral blood flow during cardiopulmonary bypass with near-infrared spectroscopy
    Roberts, IG
    Fallon, P
    Kirkham, FJ
    Kirshbom, PM
    Cooper, CE
    Elliott, MJ
    Edwards, AD
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1998, 115 (01): : 94 - 102
  • [42] Lactate measurement in whole blood using near infrared spectroscopy
    Lafrance, D
    Lands, LC
    Hornby, L
    Rohlicek, C
    Burns, DH
    CANADIAN JOURNAL OF ANALYTICAL SCIENCES AND SPECTROSCOPY, 2000, 45 (02): : 36 - 40
  • [43] MEASUREMENT OF THE BLOOD-SUPPLY TO THE ABDOMINAL TESTIS BY MEANS OF NEAR-INFRARED SPECTROSCOPY
    COLIER, WNJM
    FROELING, FMJA
    DEVRIES, JDM
    OESEBURG, B
    EUROPEAN UROLOGY, 1995, 27 (02) : 160 - 166
  • [44] Study of the FMRI blood oxygen level dependent effect by near-infrared spectroscopy
    Toronov, V
    Webb, A
    Walker, S
    Gupta, R
    Choi, JH
    Gratton, E
    Hueber, D
    SARATOV FALL MEETING 2002: OPTICAL TECHNOLOGIES IN BIOPHYSICS AND MEDICINE IV, 2002, 5068 : 222 - 226
  • [45] Near-Infrared Spectroscopy for Noninvasive Measurement of Blood Glucose: Problems, Progress, Tasks
    K. V. Pozhar
    M. O. Mikhailov
    E. L. Litinskaia
    E. A. Polyakova
    Biomedical Engineering, 2022, 56 : 64 - 68
  • [46] Near-Infrared Spectroscopy for Noninvasive Measurement of Blood Glucose: Problems, Progress, Tasks
    Pozhar, K., V
    Mikhailov, M. O.
    Litinskaia, E. L.
    Polyakova, E. A.
    BIOMEDICAL ENGINEERING-MEDITSINSKAYA TEKNIKA, 2022, 56 (01): : 64 - 68
  • [47] The effect of scalp ischaemia on measurement of cerebral blood volume by near-infrared spectroscopy
    OwenReece, H
    Elwell, CE
    Wyatt, JS
    Delpy, DT
    PHYSIOLOGICAL MEASUREMENT, 1996, 17 (04) : 279 - 286
  • [48] Cerebral Blood Flow Measurement by Near-Infrared Spectroscopy During Carotid Endarterectomy
    Kato, Shinya
    Yoshitani, Kenji
    Ohnishi, Yoshihiko
    JOURNAL OF NEUROSURGICAL ANESTHESIOLOGY, 2016, 28 (04) : 291 - 295
  • [49] Monitoring blood loss with near-infrared spectroscopy
    Torella, F
    Cowley, R
    McCollum, CN
    Thorniley, MS
    BRITISH JOURNAL OF SURGERY, 2001, 88 (05) : 753 - 753
  • [50] Pulsed near-infrared photoacoustic spectroscopy of blood
    Laufer, J
    Elwell, C
    Delpy, D
    Beard, P
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING, 2004, 5320 : 57 - 68