Development and Validation of Hematocrit Level Measurement in Dried Blood Spots Using Near-Infrared Spectroscopy

被引:18
|
作者
van de Velde, Daan [1 ]
van der Graaf, Jordy L. [1 ]
Boussaidi, Mariam [1 ]
Huisman, Ruud [1 ]
Hesselink, Dennis A. [2 ]
Russcher, Henk [3 ]
Kooij-Egas, Annelies C. [4 ]
van Maarseveen, Erik [4 ]
de Winter, Brenda C. M. [1 ]
机构
[1] Erasmus MC, Dept Hosp Pharm, Wytemaweg 80,POB 2040, NL-3015 CN Rotterdam, Netherlands
[2] Erasmus MC, Div Nephrol & Transplantat, Dept Internal Med, Rotterdam, Netherlands
[3] Erasmus MC, Dept Clin Chem, Univ Med Ctr Rotterdam, Rotterdam, Netherlands
[4] Univ Med Ctr Utrecht, Dept Hosp Pharm, Utrecht, Netherlands
关键词
PLS; spectroscopy; near-infrared; hematocrit; dried blood spot; PREDICTION; TACROLIMUS; LIPEMIA; HEMOLYSIS; ICTERUS;
D O I
10.1097/FTD.0000000000000834
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Dried blood spots (DBSs) have gained recent popularity as a sampling method for therapeutic drug monitoring. For patients, DBS sampling has several advantages over venous blood sampling. However, technical issues primarily influenced by hematocrit levels, interfere with the implementation of this method in daily clinical practice. The results of concentration measurements of drugs that are influenced by hematocrit should be corrected for hematocrit levels. In this article, we developed a fast, nondestructive, near-infrared (NIR)-based method for measuring the hematocrit in DBSs. Method: Using a partial least squares algorithm, an NIR-based quantification method was developed for measuring hematocrit levels of 0.19-0.49 L/L. Residual venous blood of 522 patients was used to build this partial least squares model. The validity of the method was evaluated using 40 patient samples. DBSs were created by adding a small amount (50 mu L) of blood on a Whatman filter paper and drying for 24 hours in a desiccator cabinet. The robustness was evaluated by measuring 24 additional samples with a high hemolysis, icterus, and lipemia (HIL) index. The hematocrit values obtained using a Sysmex XN hemocytometry analyzer were used as reference. Results: The difference between hematocrit measurements obtained with NIR spectroscopy and a hemocytometry analyzer was <15% for the 40 samples. The accuracy (<= 9%) and precision (<= 7%) for all the quality control samples were within the acceptance criteria of <15%. The intraassay and interassay coefficient of variability was <= 3% and <= 6%, respectively, for the different quality control levels. There were no deviations in the measurements for the samples with high HIL indices. The stability of hematocrit in DBS was up to 14 days for all levels. Conclusions: We developed and validated a hematocrit model using NIR spectroscopy. This nondestructive, accurate, and reproducible method has a short analysis time (51 seconds), and can be used to analyze DBS samples stored for up to 2 weeks in a desiccator cabinet.
引用
收藏
页码:351 / 357
页数:7
相关论文
共 50 条
  • [31] Validation of transcranial near-infrared spectroscopy for evaluation of cerebral blood flow autoregulation
    Olsen, KS
    Svendsen, LB
    Larsen, FS
    JOURNAL OF NEUROSURGICAL ANESTHESIOLOGY, 1996, 8 (04) : 280 - 285
  • [32] A validated method for the determination of hematocrit in dried blood spots using image analysis
    Barroso, Miguel Gambell
    Gustafsson, Louise
    Barclay, Victoria
    Linder, Camilla
    BIOANALYSIS, 2023, 15 (06) : 331 - 341
  • [33] Measurement of cardiac output using near-infrared heating of blood
    Curley, MG
    Hamilton, PS
    Walsh, JT
    LASERS IN SURGERY: ADVANCED CHARACTERIZATION, THERAPEUTICS, AND SYSTEMS VII, PROCEEDINGS OF, 1997, 2970 : 58 - 68
  • [34] An Improved Blood Glucose Measurement Using Near-Infrared Light
    Luong, Duong Trong
    Duc, Nguyen Minh
    Van, Nguyen Thu
    Ha, Nguyen Thai
    SOFT COMPUTING FOR SECURITY APPLICATIONS, ICSCS 2022, 2023, 1428 : 627 - 637
  • [35] Near-Infrared Spectroscopy on a Single Photon Level
    Foertsch, Michael
    Gerrits, Thomas
    Stevens, Martin J.
    Fuerst, Josef U.
    Schunk, Gerhard
    Sedlmeir, Florian
    Schwefel, Harald G. L.
    Strekalov, Dmitry
    Nam, Sae Woo
    Leuchs, Gerd
    Marquardt, Christoph
    2013 CONFERENCE ON LASERS AND ELECTRO-OPTICS PACIFIC RIM (CLEO-PR), 2013,
  • [36] Near-infrared spectroscopy A measurement tool for 'vegetables'?
    Arguelles-Delgado, Placido M.
    Dworschak, Martin
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2019, 36 (06) : 469 - 469
  • [37] Discovery of the near-infrared window into the body and the early development of near-infrared spectroscopy
    Jöbsis-vanderVliet, FF
    JOURNAL OF BIOMEDICAL OPTICS, 1999, 4 (04) : 392 - 396
  • [38] DEVELOPMENT OF A PORTABLE TISSUE OXIMETER USING NEAR-INFRARED SPECTROSCOPY
    SHIGA, T
    TANABE, K
    NAKASE, Y
    SHIDA, T
    CHANCE, B
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1995, 33 (04) : 622 - 626
  • [39] INFLUENCE OF BLOOD GLUCOSE LEVEL ON THE SCATTERING COEFFICIENT OF THE SKIN IN NEAR-INFRARED SPECTROSCOPY
    Kessoku, Sachiko
    Maruo, Katsuhiko
    Okawa, Shinpei
    Masamoto, Kazuto
    Yamada, Yukio
    PROCEEDINGS OF THE ASME/JSME 8TH THERMAL ENGINEERING JOINT CONFERENCE 2011, VOL 1 PTS A AND B, 2011, : 47 - +
  • [40] Measurement of Skeletal Muscle Blood Flow with Near-infrared Diffuse Correlation Spectroscopy
    Rosenberry, Ryan
    Ganesh, Chandan
    Tian, Fenghua
    Nelson, Michael D.
    FASEB JOURNAL, 2017, 31