Comparison of Immersion Ultrasound, Partial Coherence Interferometry, and Low Coherence Reflectometry for Ocular Biometry in Cataract Patients

被引:25
|
作者
Montes-Mico, Robert [1 ]
Carones, Francesco [2 ]
Buttacchio, Antonietta [2 ]
Ferrer-Blasco, Teresa [1 ]
Madrid-Costa, David [1 ]
机构
[1] Univ Valencia, Optometry Res Grp, Valencia, Spain
[2] Carones Ophthalmol Ctr, Milan, Italy
关键词
LENS POWER CALCULATION; AXIAL LENGTH; DEVICE; ACCURACY; CONTACT;
D O I
10.3928/1081597X-20110202-01
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare ocular biometry parameters measured with immersion ultrasound, partial coherence interferometry, and low coherence reflectometry in cataract patients. METHODS: Measurements of axial length and anterior chamber depth were analyzed and compared using immersion ultrasound, partial coherence interferometry, and low coherence reflectometry. Keratometry (K), flattest axis, and white-to-white measurements were compared between partial coherence interferometry and low coherence reflectometry. Seventy-eight cataract (LOCS II range: 1 to 3) eyes of 45 patients aged between 42 and 90 years were evaluated. A subanalysis as a function of cataract degree was done for axial length and anterior chamber depth between techniques. RESULTS: No statistically significant differences were noted for the study cohort or within each cataract degree among the three techniques for axial length and anterior chamber depth (P>.05, ANOVA test). Measurements between techniques were highly correlated for axial length (R=0.99) and anterior chamber depth (R=0.90 to 0.96) for all methods. Keratometry, flattest axis, and white-to-white measurements were comparable (paired t test, P>.1) and correlated well between partial coherence interferometry and low coherence reflectometry (K1 [R=0.95], K2 [R=0.97], flattest axis [R=0.95], and white-to-white [R=0.92]). CONCLUSIONS: Immersion ultrasound, partial coherence interferometry, and low coherence reflectometry provided comparable ocular biometry measurements in cataractous eyes. [J Refract Surg. 2011;27(9):665-671.] doi:10.3928/1081597X-20110202-01
引用
收藏
页码:664 / 670
页数:7
相关论文
共 50 条
  • [1] Comparison of immersion ultrasound and low coherence reflectometry for ocular biometry in cataract patients
    Yan Li
    Hong-Xun Li
    Yang-Chen Liu
    Ya-Tu Guo
    Jian-Min Gao
    Bin Wu
    Nan Zhang
    Dong Liu
    Xiao-Yong Yuan
    [J]. International Journal of Ophthalmology, 2018, (06) : 966 - 969
  • [2] Comparison of immersion ultrasound and low coherence reflectometry for ocular biometry in cataract patients
    Li, Yan
    Li, Hong-Xun
    Liu, Yang-Chen
    Guo, Ya-Tu
    Gao, Jian-Min
    Wu, Bin
    Zhang, Nan
    Liu, Dong
    Yuan, Xiao-Yong
    [J]. INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2018, 11 (06) : 966 - 969
  • [3] A new optical low coherence reflectometry device for ocular biometry in cataract patients
    Buckhurst, P. J.
    Wolffsohn, J. S.
    Shah, S.
    Naroo, S. A.
    Davies, L. N.
    Berrow, E. J.
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2009, 93 (07) : 949 - 953
  • [4] Ocular biometry in dense cataracts: Comparison of partial-coherence interferometry, swept-source optical coherence tomography and immersion ultrasound
    Gonzalez-Godinez, Sara
    Saucedo-Urdapilleta, Roxana
    Mayorquin-Ruiz, Mariana
    Velasco-Barona, Cecilio
    Moragrega-Adame, Eduardo
    Dominguez-Varela, Irving A.
    Gonzalez-Salinas, Roberto
    [J]. INDIAN JOURNAL OF OPHTHALMOLOGY, 2022, 70 (01) : 107 - +
  • [5] Comparison of Partial Coherence Interferometry and Optic Low Coherence Reflectometry for Intraocular Lens Power Calculation in Cataract Patients
    Dogan, Mustafa
    Polat, Onur
    Karadas, Mahmut
    Kusbeci, Tuncay
    Yavas, Guliz Fatma
    Inan, Sibel
    Inan, Umit Ubeyt
    [J]. TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2014, 44 (06): : 419 - 423
  • [6] Comparison of Two Partial Coherence Interferometry Devices for Ocular Biometry
    Liampa, Z.
    Kynigopoulos, M.
    Pallas, G.
    Gerding, H.
    [J]. KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2010, 227 (04) : 285 - 288
  • [7] Comparison of immersion ultrasound biometry and partial coherence interferometry for intraocular lens calculation according to Haigis
    W. Haigis
    B. Lege
    N. Miller
    B. Schneider
    [J]. Graefe's Archive for Clinical and Experimental Ophthalmology, 2000, 238 : 765 - 773
  • [8] Comparison of immersion ultrasound biometry and partial coherence interferometry for intraocular lens calculation according to Haigis
    Haigis, W
    Lege, B
    Miller, N
    Schneider, B
    [J]. GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2000, 238 (09) : 765 - 773
  • [9] Comparison of partial coherence interferometry and ultrasound for anterior segment biometry
    Lara, Francisco
    Fernandez-Sanchez, Vicente
    Lopez-Gil, Norberto
    Cervino, Alejandro
    Montes-Mico, Robert
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (02): : 324 - 329
  • [10] Meta-analysis of optical low-coherence reflectometry versus partial coherence interferometry biometry
    Jinhai Huang
    Colm McAlinden
    Yingying Huang
    Daizong Wen
    Giacomo Savini
    Ruixue Tu
    Qinmei Wang
    [J]. Scientific Reports, 7