Comparison of Two Partial Coherence Interferometry Devices for Ocular Biometry

被引:22
|
作者
Liampa, Z.
Kynigopoulos, M. [2 ]
Pallas, G. [2 ]
Gerding, H. [1 ,3 ]
机构
[1] Klin Pallas, Abt Retinol, Dept Retinol, CH-4600 Olten, Switzerland
[2] Klin Pallas, Dept Cataract Surg, CH-4600 Olten, Switzerland
[3] Univ Munster, Dept Ophthalmol, Munster, Germany
关键词
biometry; cataract surgery; partial coherence interferometry; LASER-DOPPLER INTERFEROMETRY; LENGTH; EYE;
D O I
10.1055/s-0029-1245182
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background: An estimation of the repeatability of the Lenstar LS900 biometry parameters and comparison of these measurements to those evaluated with the IOLMaster were carried out. Patients and Methods: Axial length, corneal curvature, anterior chamber depth, central corneal thickness and lens thickness measurements were performed in 145 eyes using the Lenstar LS900, while axial length, corneal curvature and anterior chamber depth were measured using the IOLMaster. The repeatability coefficients and the coefficients of variation were assessed. The Bland-Altman plots and the regression analysis were applied to evaluate the differences between the two methods. Results: Axial length was the most repeatable parameter and lens thickness the most variable. Axial length and corneal curvature measurements by IOLMaster and Lenstar LS900 showed a good correlation (mean differences: 0.03 and 0.01 mm). Anterior chamber depth measurements by the two instruments resulted in a difference of 0.2mm (all p values < 0.0001). Regression analysis showed a highly significant correlation between measurements by the two methods. Correlation coefficients were: axial length 0.999, corneal curvature 0.983, anterior chamber depth 0.925 (p < 0.0001). Bland-Altman plots demonstrated that measurements by the tested devices were closely related without systematic effects in the range of evaluated data. Conclusion: Lenstar measurements yielded a high repeatability and correlate highly significant with the IOLMaster measurements.
引用
收藏
页码:285 / 288
页数:4
相关论文
共 50 条
  • [1] Comparison of Immersion Ultrasound, Partial Coherence Interferometry, and Low Coherence Reflectometry for Ocular Biometry in Cataract Patients
    Montes-Mico, Robert
    Carones, Francesco
    Buttacchio, Antonietta
    Ferrer-Blasco, Teresa
    Madrid-Costa, David
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2011, 27 (09) : 664 - 670
  • [2] Comparison of partial coherence interferometry and ultrasound for anterior segment biometry
    Lara, Francisco
    Fernandez-Sanchez, Vicente
    Lopez-Gil, Norberto
    Cervino, Alejandro
    Montes-Mico, Robert
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (02): : 324 - 329
  • [3] Ocular biometry in dense cataracts: Comparison of partial-coherence interferometry, swept-source optical coherence tomography and immersion ultrasound
    Gonzalez-Godinez, Sara
    Saucedo-Urdapilleta, Roxana
    Mayorquin-Ruiz, Mariana
    Velasco-Barona, Cecilio
    Moragrega-Adame, Eduardo
    Dominguez-Varela, Irving A.
    Gonzalez-Salinas, Roberto
    [J]. INDIAN JOURNAL OF OPHTHALMOLOGY, 2022, 70 (01) : 107 - +
  • [4] Comparison of Ocular Biometry Measurements Using A-Scan Ultrasound and Two Types of Partial Coherence Interferometers
    Ha, Dae Young
    Lee, Kang Won
    Jung, Ji Won
    [J]. JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2016, 57 (05): : 757 - 762
  • [5] Accuracy and reproducibility of biometry using partial coherence interferometry
    Connors, R
    Boseman, P
    Olson, RJ
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (02): : 235 - 238
  • [6] Axial length comparison between two ultrasound devices and a partial coherence interferometry device
    Tran, Hang
    Yum, Kevin
    Taibl, Jessica
    Hjelmstad, David
    Sayegh, Samir I.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [7] Comparative analysis of two optical biometry devices: high wavelength swept source OCT versus partial coherence interferometry
    Szalai, Eszter
    Csutak, Adrienne
    [J]. INTERNATIONAL OPHTHALMOLOGY, 2022, 42 (02) : 627 - 634
  • [8] Comparative analysis of two optical biometry devices: high wavelength swept source OCT versus partial coherence interferometry
    Eszter Szalai
    Adrienne Csutak
    [J]. International Ophthalmology, 2022, 42 : 627 - 634
  • [9] Comparison of ocular biometry in Chinese patients using two swept-source optical coherence tomography devices
    Ho, Vivian Wing -Man
    Nguyen, Hong Chau
    Wong, Siu-Hong
    Li, Anita Lai-Wah
    Li, Kenneth Kai Wang
    [J]. ANNALS OF EYE SCIENCE, 2023, 8
  • [10] Partial coherence interferometry: A novel approach to biometry in cataract surgery
    Drexler, W
    Findl, O
    Menapace, R
    Rainer, G
    Vass, C
    Hitzenberger, CK
    Fercher, AF
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 1998, 126 (04) : 524 - 534