Stent Coverage and Neointimal Proliferation in Bare Metal Stents Postdilated With a Paclitaxel-Eluting Balloon Versus Everolimus-Eluting Stents Prospective Randomized Study Using Optical Coherence Tomography at 6-Month Follow-Up

被引:29
|
作者
Poerner, Tudor C. [1 ]
Otto, Sylvia
Gassdorf, Johannes [1 ]
Nitsche, Kristina [1 ]
Janiak, Florian [1 ]
Scheller, Bruno [2 ]
Goebel, Bjoern [1 ]
Jung, Christian [1 ]
Figulla, Hans R. [1 ]
机构
[1] Univ Hosp Jena, Dept Med 1, Div Cardiol, Jena, Germany
[2] Univ Saarland, D-66123 Saarbrucken, Germany
关键词
coronary stenosis; drug-eluting stents; percutaneous coronary intervention; tomography; optical coherence; transluminal coronary balloon dilation; PERCUTANEOUS CORONARY INTERVENTION; DUAL-ANTIPLATELET THERAPY; COATED BALLOON; CONVENTIONAL ANGIOPLASTY; ARTERY-DISEASE; RESTENOSIS; LESIONS; TRIAL; IMPLANTATION; REVASCULARIZATION;
D O I
10.1161/CIRCINTERVENTIONS.113.001146
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-In this randomized trial, strut coverage and neointimal proliferation of a therapy of bare metal stents (BMSs) postdilated with the paclitaxel drug-eluting balloon (DEB) was compared with everolimus drug-eluting stents (DESs) at 6-month follow-up using optical coherence tomography. We hypothesized sufficient stent coverage at follow-up. Methods and Results-A total of 105 lesions in 90 patients were treated with either XIENCE V DES (n=51) or BMS postdilated with the SeQuent Please DEB (n=54). At follow-up, comparable results on the primary optical coherence tomography end point (percentage uncovered struts 5.64+/-9.65% in BMS+DEB versus 4.93+/-9.29% in DES; P=0.366) were found. Thus, BMS+DEB achieved the prespecified noninferiority margin of 5% uncovered struts versus DES (difference between treatment means, 0.71%; one-sided upper 95% confidence interval, 4.14%; noninferiority P=0.04). Optical coherence tomography analysis showed significantly more global neointimal proliferation in the BMS+DEB group (15.7+/-7.8 versus 11.0+/-5.2 mm(3) proliferation volume/cm stent length; P=0.002). No significant focal in-stent stenosis analyzed with angiography (percentage diameter stenosis at follow-up, 22.8+/-11.9 versus 16.9+/-10.4; P=0.014) and optical coherence tomography (peak local area stenosis, 39.5+/-13.8% versus 36.8+/-15.6%; P=0.409) was found. Conclusions-Good stent strut coverage of >94% was found in both therapy groups. Despite greater suppression of global neointimal growth in DES, both DES and BMS+DEB effectively prevented clinically relevant focal restenosis at 6-month follow-up.
引用
收藏
页码:760 / U53
页数:10
相关论文
共 50 条
  • [1] A PROSPECTIVE RANDOMIZED STUDY USING OPTICAL COHERENCE TOMOGRAPHY TO ASSESS ENDOTHELIAL COVERAGE AND NEOINTIMAL PROLIFERATION AT 6 MONTHS AFTER IMPLANTATION OF A CORONARY EVEROLIMUS-ELUTING STENT COMPARED WITH A BARE METAL STENT POSTDILATED WITH A PACLITAXEL-ELUTING BALLOON (OCTOPUS TRIAL)
    Poerner, Tudor C.
    Otto, Sylvia
    Janiak, Florian
    Gassdorf, Johannes
    Figulla, Hans R.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (13) : E281 - E281
  • [2] Six-month follow-up evaluation for everolimus-eluting stents by intracoronary optical coherence tomography: Comparison with paclitaxel-eluting stents
    Takano, Masamichi
    Murakami, Daisuke
    Yamamoto, Masanori
    Kurihara, Osamu
    Murai, Koji
    Inami, Toru
    Kimata, Nakahisa
    Ohba, Takayoshi
    Seino, Yoshihiko
    Mizuno, Kyoichi
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 166 (01) : 181 - 186
  • [3] Optical Coherence Tomography Analysis for Restenosis of Everolimus-Eluting Stents In Comparison with Bare-Metal Stents and Paclitaxel-Eluting Stents
    Kuramitsu, Shoichi
    Iwabuchi, Masashi
    Toyota, Fumitoshi
    Haraguchi, Takuya
    Kazuno, Yoshio
    Enomoto, Soichiro
    Mazaki, Toru
    Domei, Takenori
    Hyodo, Makoto
    Shirai, Shinichi
    Takabatake, Yoshitaka
    Yokoi, Hiroyoshi
    Nobuyoshi, Masakiyo
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 58 (20) : B181 - B181
  • [4] A prospective randomized trial using optical coherence tomography to compare the Xience V everolimus-eluting stent with a bare metal stent postdilated with a paclitaxel-eluting balloon (OCTOPUS Trial)
    Poerner, T. C.
    Otto, S.
    Janiak, F.
    Gassdorf, J.
    Nitsche, K.
    Jung, C.
    Goebel, B.
    Figulla, H. R.
    EUROPEAN HEART JOURNAL, 2012, 33 : 520 - 520
  • [5] Everolimus-Eluting Versus Paclitaxel-Eluting Stents for Treatment of Bare Metal Stent Restenosis
    Almalla, Mohammad
    Schroeder, Joerg W.
    Pross, Verena
    Stegemann, Emilia
    Marx, Nikolaus
    Hoffmann, Rainer
    AMERICAN JOURNAL OF CARDIOLOGY, 2011, 108 (04): : 518 - 522
  • [6] Neointimal coverage of sirolimus-eluting stents at 6-month follow-up: evaluated by optical coherence tomography
    Matsumoto, Daisuke
    Shite, Junya
    Shinke, Toshiro
    Otake, Hiromasa
    Tanino, Yusuke
    Ogasawara, Daisuke
    Sawada, Takahiro
    Paredes, Oscar Luis
    Hirata, Ken-ichi
    Yokoyama, Mitsuhiro
    EUROPEAN HEART JOURNAL, 2007, 28 (08) : 961 - 967
  • [7] Comparison of neointimal coverage between everolimus-eluting stents and sirolimus-eluting stents: an optical coherence tomography substudy of the RESET (Randomized Evaluation of Sirolimus-eluting versus Everolimus-eluting stent Trial)
    Kubo, Takashi
    Akasaka, Takashi
    Kozuma, Ken
    Kimura, Kazuo
    Kawamura, Masaki
    Sumiyoshi, Tetsuya
    Ino, Yasushi
    Morino, Yoshihiro
    Tanabe, Kengo
    Kadota, Kazushige
    Kimura, Takeshi
    EUROINTERVENTION, 2015, 11 (05) : 564 - 571
  • [8] A prospective randomised study using optical coherence tomography to assess endothelial coverage and neointimal proliferation at 6-months after implantation of a coronary everolimus-eluting stent compared with a bare metal stent postdilated with a paclitaxel-eluting balloon (OCTOPUS trial): rationale, design and methods
    Poerner, Tudor C.
    Otto, Sylvia
    Gassdorf, Johannes
    Janiak, Florian
    Danzer, Constance
    Ferrari, Markus
    Figulla, Hans R.
    EUROINTERVENTION, 2011, 7 : K93 - K99
  • [9] Comparison by Optical Coherence Tomography of Paclitaxel-Eluting Stents With Sirolimus-Eluting Stents Implanted in One Coronary Artery in One Procedure - 6-Month Follow-up
    Miyoshi, Naoki
    Shite, Junya
    Shinke, Toshiro
    Otake, Hiromasa
    Tanino, Yusuke
    Ogasawara, Daisuke
    Sawada, Takahiro
    Kawamori, Hiroyuki
    Kato, Hiroki
    Yoshino, Naoki
    Kozuki, Amane
    Hirata, Ken-ichi
    CIRCULATION JOURNAL, 2010, 74 (05) : 903 - 908
  • [10] Serial Changes of Neointimal Coverage Condition and Characteristic are Different between Sirolimus-Eluting Stents, Paclitaxel-Eluting Stents and Zotalolimus-Eluting Stents Implantation: Follow-Up Optical Coherence Tomography Study
    Nakamura, Daisuke
    Nishino, Masami
    Lee, Yasuharu
    Yoshimura, Takahiro
    Taniike, Masayuki
    Makino, Nobuhiko
    Kato, Hiroyasu
    Egami, Yasuyuki
    Shutta, Ryu
    Tanouchi, Jun
    Yamada, Yoshio
    CIRCULATION, 2011, 124 (21)