Cardiovascular effects at multi-detector row CT colonography compared with those at conventional endoscopy of the colon

被引:18
|
作者
Taylor, SA
Halligan, S
O'Donnell, C
Morley, S
Mistry, H
Saunders, BP
Vance, M
Bassett, P
Windsor, A
Stern, Y
Bethel, H
Atkin, W
Bartram, CI
机构
[1] St Marks Hosp, Dept Intestinal Imaging, London HA1 3UJ, England
[2] St Marks Hosp, Wolfson Inst Endoscopy, London HA1 3UJ, England
[3] St Marks Hosp, Dept Cardiol, London HA1 3UJ, England
[4] St Marks Hosp, Canc Res UK Colorectal Canc Unit, London HA1 3UJ, England
关键词
colon; colonscopy; heart; arrhythmia;
D O I
10.1148/radiol.2293021537
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To compare the cardiovascular effects of computed tomographic (CT) colonography and conventional endoscopy in a group of patients undergoing both procedures. MATERIALS AND METHODS: A total of 144 patients underwent CT colonography followed by flexible sigmoidoscopy (40 patients) or colonoscopy (104 patients). Pulse, blood pressure, and oxygen saturation were measured before, during, and after the procedures. Forty patients also underwent continuous Holter electrocardiographic (ECG) monitoring. Periprocedural pain was assessed by using a handheld counting device. Outcome variables were assessed by using a combination of paired t testing and multilevel linear regression. RESULTS: When a spasmolytic was not used, CT colonography was associated with only a small increase in oxygen saturation (P = .03), while use of a spasmolytic caused an increase in pulse (mean increase, 19.9 beats per minute; P < .001) and diastolic blood pressure (mean increase, 5 mm Hg; P < .001). Compared with that at CT, oxygen saturation decreased significantly during and after colonoscopy and sigmoidoscopy (mean decrease after colonoscopy with sedation, 1.0%; P < .001). Systolic and diastolic blood pressure also decreased during and after colonoscopy (mean systolic decrease after colonoscopy with sedation, 16.6 mm Hg, P < .001; mean diastolic decrease after colonoscopy with sedation, 7.5 mm Fig, P < .001). Patients were 30.3 times more likely to develop bradycardia after endoscopy (95% CI: 2.65, 346; P =.006). Ventricular couplets were significantly higher at endoscopy than at CT in patients with a history of cardiac disease (odds ratio: 72.5 and 95% CI: 4.56, 1,153 at CT vs odds ratio: 14.6 and 95% CI: 0.96, 222 at endoscopy; P = .002). Patients were 1.89 times more likely to register pain during colonoscopy than during CT (95% CI: 1.06, 3.38; P = .03). CONCLUSION: CT colonography had no significant cardiovascular effect other than spasmolytic-induced tachycardia. Endoscopy-and colonoscopy in particular-causes cardiovascular effects that are largely related to sedation. CT colonography is less painful than colonoscopy and is comparable to flexible sigmoidoscopy. (C) RSNA, 2003.
引用
收藏
页码:782 / 790
页数:9
相关论文
共 50 条
  • [21] Pitfalls in multi detector row CT colonography: A systematic approach
    Mang, Thomas
    Maier, Andrea
    Plank, Christina
    Mueller-Mang, Christina
    Herold, Christian
    Schima, Wolfgang
    RADIOGRAPHICS, 2007, 27 (02) : 431 - 454
  • [22] Optimizing colonic distention for multi-detector row CT colonography: Effect of hyoscine butylbromide and rectal balloon catheter
    Taylor, SA
    Halligan, S
    Goh, V
    Morley, S
    Bassett, P
    Atkin, W
    Bartram, CI
    RADIOLOGY, 2003, 229 (01) : 99 - 108
  • [23] Benefits of contrast-enhanced multi-detector row CT colonography for preoperative staging in colorectal cancer patients
    Iinuma, G
    Moriyama, N
    Satake, M
    Miyakawa, K
    Muramatsu, Y
    Tateishi, U
    Akasu, T
    Otake, Y
    Fujii, T
    Kobayashi, T
    MEDICAL IMAGING 2003: PHYSIOLOGY AND FUNCTION: METHODS, SYSTEMS, AND APPLICATIONS, 2003, 5031 : 398 - 404
  • [24] False-negative results at multi-detector row CT colonography: Multivariate analysis of causes for missed lesions
    Park, SH
    Ha, HK
    Kim, MJ
    Kim, KW
    Kim, AY
    Yang, DH
    Lee, MG
    Kim, PN
    Shin, YM
    Yang, SK
    Myung, SJ
    Min, YI
    RADIOLOGY, 2005, 235 (02) : 495 - 502
  • [25] Multi-detector row CT colonography: Effect of collimation, pitch, and orientation on polyp detection in a human colectomy specimen
    Taylor, SA
    Halligan, S
    Bartram, CI
    Morgan, PR
    Talbot, IC
    Fry, N
    Saunders, BP
    Khosraviani, K
    Atkin, W
    RADIOLOGY, 2003, 229 (01) : 109 - 118
  • [26] Science to practice - What multi-detector row CT parameters are best for detection of colon polyps?
    Brink, JA
    RADIOLOGY, 2003, 229 (01) : 1 - 2
  • [27] Bronchial and nonbronchial systemic arteries at multi-detector row CT angiography: Comparison with conventional angiography
    Remy-Jardin, M
    Bouaziz, N
    Dumont, P
    Brillet, PY
    Bruzzi, J
    Remy, J
    RADIOLOGY, 2004, 233 (03) : 741 - 749
  • [28] Diagnosis of venous thromboembolism by single-detector row and multi-detector row CT angiography
    Koyuncu, Abdullah
    Bozlar, Ugur
    Ustunsoz, Bahri
    Ors, Fatih
    Tasar, Mustafa
    Deniz, Omer
    Balkan, Arzu
    Somuncu, Ibrahim
    TUBERKULOZ VE TORAK-TUBERCULOSIS AND THORAX, 2007, 55 (01): : 24 - 33
  • [29] Multi-detector row spiral CT pulmonary angiography: Comparison with single-detector row spiral CT
    Raptopoulos, V
    Boiselle, PM
    RADIOLOGY, 2001, 221 (03) : 606 - 613
  • [30] Multi-detector row CT of mesenteric ischemia: Can it be done?
    Horton, KM
    Fishman, EK
    RADIOGRAPHICS, 2001, 21 (06) : 1463 - 1473