Analysis of temperature field and effect of cold-formed stainless steel roof panels

被引:4
|
作者
Wang, Dayang [1 ,3 ]
Xin, Zhiyong [2 ,3 ]
Wang, Mingming [1 ]
Ou, Tong [3 ,4 ]
Mao, Jihua [5 ]
Zhu, Yong [1 ]
Tan, Jian [4 ]
机构
[1] Guangzhou Univ, Sch Civil Engn, Guangzhou 510006, Peoples R China
[2] Zhuhai Envete Engn Testing Co LTD, Guangzhou 519000, Peoples R China
[3] Guangdong Engn Res Ctr Met Cladding & Roofing Syst, Zhaoqing 510006, Peoples R China
[4] Architectural Design & Res Inst Guangdong Prov, Guangzhou 510000, Peoples R China
[5] Guangzhou guangjian construction Engn testing Ctr, Guangzhou 510600, Peoples R China
基金
中国国家自然科学基金;
关键词
Experiments and numerical study; Temperature field; Thermal effects; Solar radiation; Roof panels; THERMAL-BEHAVIOR; BATTENS SUBJECT; MEMBERS;
D O I
10.1016/j.jcsr.2022.107575
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The thermal effects on large-span metal roof systems are significant due to solar radiation. In this paper, the temperature field and variations of monomer stainless steel (MSS) roof panels and continuous welded stainless steel (CWSS) roof panels are investigated. The MSS roof panels are considered different surface roughness, horizontal inclination angle and spatial location, and the CWSS roof panels are studied the influence of hori-zontal inclination angle and spatial location. Based on the test result, the temperature field and variations of the roof panels in a typical day, different light intensities, and wind speeds are analyzed in detail. Numerical simulation is further used to compare with the experimental results. The overall and local stress and deformation characteristics of the CWSS roof are analyzed, and relevant design improvement is proposed. The feasibility of a simplified temperature calculation approach for CWSS roof panels is verified by experimental and numerical results. The experimental and numerical study demonstrates that the temperature field and thermal effects on roof panels are significant. The maximum temperature of the roof panels reached 56.8 degrees C, and the maximum temperature difference is 28.3 degrees C compared with ambient air temperature. The temperature stress can reach 65.8% of the yield strength, and the temperature deformation can reach 1/1600 of the roof span, which will be more obvious in the practical roof system.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] High temperature tests of cold-formed stainless steel double shear bolted connections
    Cai, Yancheng
    Young, Ben
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2015, 104 : 49 - 63
  • [22] Effect of high temperature on mechanical properties of cold-formed structural steel
    Outinen, J
    Mäkeläinen, P
    TUBULAR STRUCTURES IX, 2001, : 439 - 444
  • [23] Cold-formed stainless steel sections subjected to web crippling
    Zhou, F
    Young, B
    JOURNAL OF STRUCTURAL ENGINEERING, 2006, 132 (01) : 134 - 144
  • [24] WEB CRIPPLING OF STAINLESS-STEEL COLD-FORMED BEAMS
    KORVINK, SA
    VANDENBERG, GJ
    VANDERMERWE, P
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 1995, 34 (2-3) : 225 - 248
  • [25] Behaviour of cold-formed lean duplex stainless steel sections
    Huang, Y.
    Young, B.
    TUBULAR STRUCTURES XIV, 2012, : 399 - 405
  • [26] Behavior of cold-formed high strength stainless steel sections
    Young, B
    Lui, WM
    JOURNAL OF STRUCTURAL ENGINEERING, 2005, 131 (11) : 1738 - 1745
  • [27] Behaviour of cold-formed stainless steel beams at elevated temperatures
    Ju Chen
    Wei-liang Jin
    Journal of Zhejiang University-SCIENCE A, 2008, 9 : 1507 - 1513
  • [28] Structural behavior of cold-formed stainless steel bolted connections
    Cai, Yancheng
    Young, Ben
    THIN-WALLED STRUCTURES, 2014, 83 : 147 - 156
  • [29] Tests of cold-formed stainless steel tubular flexural members
    Zhou, F
    Young, B
    THIN-WALLED STRUCTURES, 2005, 43 (09) : 1325 - 1337
  • [30] Behavior and design for component and system of cold-formed steel roof trusses
    Reda, M.
    Sharaf, T.
    ElSabbagh, A.
    ElGhandour, M.
    THIN-WALLED STRUCTURES, 2019, 135 : 21 - 32