Analysis of temperature field and effect of cold-formed stainless steel roof panels

被引:4
|
作者
Wang, Dayang [1 ,3 ]
Xin, Zhiyong [2 ,3 ]
Wang, Mingming [1 ]
Ou, Tong [3 ,4 ]
Mao, Jihua [5 ]
Zhu, Yong [1 ]
Tan, Jian [4 ]
机构
[1] Guangzhou Univ, Sch Civil Engn, Guangzhou 510006, Peoples R China
[2] Zhuhai Envete Engn Testing Co LTD, Guangzhou 519000, Peoples R China
[3] Guangdong Engn Res Ctr Met Cladding & Roofing Syst, Zhaoqing 510006, Peoples R China
[4] Architectural Design & Res Inst Guangdong Prov, Guangzhou 510000, Peoples R China
[5] Guangzhou guangjian construction Engn testing Ctr, Guangzhou 510600, Peoples R China
基金
中国国家自然科学基金;
关键词
Experiments and numerical study; Temperature field; Thermal effects; Solar radiation; Roof panels; THERMAL-BEHAVIOR; BATTENS SUBJECT; MEMBERS;
D O I
10.1016/j.jcsr.2022.107575
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The thermal effects on large-span metal roof systems are significant due to solar radiation. In this paper, the temperature field and variations of monomer stainless steel (MSS) roof panels and continuous welded stainless steel (CWSS) roof panels are investigated. The MSS roof panels are considered different surface roughness, horizontal inclination angle and spatial location, and the CWSS roof panels are studied the influence of hori-zontal inclination angle and spatial location. Based on the test result, the temperature field and variations of the roof panels in a typical day, different light intensities, and wind speeds are analyzed in detail. Numerical simulation is further used to compare with the experimental results. The overall and local stress and deformation characteristics of the CWSS roof are analyzed, and relevant design improvement is proposed. The feasibility of a simplified temperature calculation approach for CWSS roof panels is verified by experimental and numerical results. The experimental and numerical study demonstrates that the temperature field and thermal effects on roof panels are significant. The maximum temperature of the roof panels reached 56.8 degrees C, and the maximum temperature difference is 28.3 degrees C compared with ambient air temperature. The temperature stress can reach 65.8% of the yield strength, and the temperature deformation can reach 1/1600 of the roof span, which will be more obvious in the practical roof system.
引用
收藏
页数:14
相关论文
共 50 条
  • [11] Tensile Tests of Cold-Formed Stainless Steel Tubes
    Chen, Man-Tai
    Young, Ben
    JOURNAL OF STRUCTURAL ENGINEERING, 2020, 146 (09)
  • [12] Tests on cold-formed and welded stainless steel members
    Talja, A
    LIGHT-WEIGHT STEEL AND ALUMINIUM STRUCTURES, 1999, : 531 - 538
  • [13] Design of cold-formed CHS braces for steel roof structures
    Hassanein, M. F.
    Elchalakani, Mohamed
    Elkawas, A. A.
    THIN-WALLED STRUCTURES, 2017, 120 : 249 - 259
  • [14] STRUCTURAL-ANALYSIS AND DESIGN OF SANDWICH PANELS WITH COLD-FORMED STEEL FACINGS
    CHONG, KP
    HARTSOCK, JA
    THIN-WALLED STRUCTURES, 1993, 16 (1-4) : 199 - 218
  • [15] Modelling hysteretic behaviour of cold-formed steel wall panels
    Nithyadharan, M.
    Kalyanaraman, V.
    ENGINEERING STRUCTURES, 2013, 46 : 643 - 652
  • [16] Effective shear modulus trends for cold-formed steel panels
    Keener, JD
    Manbeck, HB
    TRANSACTIONS OF THE ASAE, 1996, 39 (05): : 1817 - 1824
  • [17] Seismic characteristics of hybrid cold-formed steel wall panels
    Usefi, Nima
    Ronagh, Hamid
    STRUCTURES, 2020, 27 : 718 - 731
  • [18] Experimental investigation on composite panels of cold-formed steel and timber
    Kyvelou, Pinelopi
    Reynolds, Thomas P. S.
    Beckett, Christopher T. S.
    Huang, Yuner
    ENGINEERING STRUCTURES, 2021, 247
  • [19] Experimental investigation on composite panels of cold-formed steel and timber
    Kyvelou, Pinelopi
    Reynolds, Thomas P.S.
    Beckett, Christopher T.S.
    Huang, Yuner
    Engineering Structures, 2021, 247
  • [20] Numerical simulation and effect of curling on bolted connections in cold-formed stainless steel
    Kim, Tae Soo
    Han, Byum Seok
    ISIJ INTERNATIONAL, 2007, 47 (06) : 920 - 929