Effect of implant surface properties on peri-implant bone healing: a histological and histomorphometric study in dogs

被引:25
|
作者
Al-Hamdan, Khalid [2 ,3 ]
Al-Moaber, Samar H. [2 ]
Junker, Rudiger [4 ]
Jansen, John A. [1 ,4 ]
机构
[1] King Saud Univ, Coll Dent, Dent Implant & Osseointegrat Res Chair DIORC, Riyadh, Saudi Arabia
[2] King Saud Univ, Coll Dent, Dept Periodontol & Community Dent, Riyadh, Saudi Arabia
[3] King Saud Univ, Eng AB Res Chair Growth Factors & Bone Regenerat, Riyadh, Saudi Arabia
[4] Radboud Univ Nijmegen, Med Ctr, Dept Biomat, NL-6500 HB Nijmegen, Netherlands
关键词
dental implant; bone contact; dog model; NanoTite (TM); resonance frequency analysis; SLActive (R); surface modification; titanium; FRESH EXTRACTION SOCKETS; DEHISCENCE-TYPE DEFECTS; TITANIUM IMPLANTS; INTEGRATION; HYDROPHILICITY; REGENERATION; APPOSITION; STABILITY; ENERGY;
D O I
10.1111/j.1600-0501.2010.02106.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim The present study aimed to evaluate and compare two types of implants, i.e. grit-blasted and acid-etched implants (SLActive (R)) with nano-meter-scale hydroxyapatite surface-modified implants (NanoTite (TM)). Material and methods For histological and histomorphometrical evaluation, 22 SLActive (R) and 22 Nanotite (TM) implants were inserted in eleven Beagle dogs. The animals were divided into three groups of healing (A: 2 weeks; B: 4 weeks and C: 8 weeks). Two, 4 and 8 weeks after implantation, the animals were sacrificed and bone-to-implant contact (BIC %), first implant-bone contact (1st BIC) as well as amount of bone (BV) were assessed. Results For SLActive (R) and Nanotite (TM) implants, BIC% increased significantly over time. No statistically significant differences in BIC% were found between SLActive (R) and Nanotite (TM) at all the respective implantation times. Moreover, for the different healing periods, no significant differences for BV between SLActive (R) and Nanotite (TM) implants were found. Conclusions The present study showed that SLActive (R) and NanoTite (TM) implants induce a similar bone response after implantation for 2, 4 and 8 weeks in a non-submerged position in the mandible of dogs. To cite this article:Al-Hamdan K, Al-Moaber SH, Junker R, Jansen JA. Effect of implant surface properties on peri-implant bone healing: a histological and histomorphometric study in dogs.Clin. Oral Impl. Res. 22, 2011; 399-405.
引用
收藏
页码:399 / 405
页数:7
相关论文
共 50 条
  • [41] Morphogenesis of the peri-implant mucosa: an experimental study in dogs
    Berglundh, Tord
    Abrahamsson, Ingemar
    Welander, Maria
    Lang, Niklaus P.
    Lindhe, Jan
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2007, 18 (01) : 1 - 8
  • [42] Effects of implant geometry, surface properties, and TGF-β1 on peri-implant bone response: an experimental study in goats
    Schouten, C.
    Meijer, G. J.
    van den Beucken, J. J. J. P.
    Spauwen, P. H. M.
    Jansen, J. A.
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2009, 20 (04) : 421 - 429
  • [43] Effect of collagen fibril orientation on the anisotropic properties of peri-implant bone
    Lucas Colabella
    Salah Naili
    Sophie Le Cann
    Guillaume Haiat
    [J]. Biomechanics and Modeling in Mechanobiology, 2024, 23 : 879 - 891
  • [44] Influence of different implant surfaces on peri-implant osteogenesis: Histomorphometric analysis in sheep
    Franchi, Marco
    Bacchelli, Beatrice
    Giavaresi, Gianluca
    De Pasquale, Viviana
    Martini, Desiree
    Fini, Milena
    Giardino, Roberto
    Ruggeri, Alessandro
    [J]. JOURNAL OF PERIODONTOLOGY, 2007, 78 (05) : 879 - 888
  • [45] Effect of collagen fibril orientation on the anisotropic properties of peri-implant bone
    Colabella, Lucas
    Naili, Salah
    Le Cann, Sophie
    Haiat, Guillaume
    [J]. BIOMECHANICS AND MODELING IN MECHANOBIOLOGY, 2024, 23 (03) : 879 - 891
  • [46] HISTOLOGICAL PERSPECTIVES ON DENTAL IMPLANT FAILURE: A CASE REPORT AND ANALYSIS OF PERI-IMPLANT BONE HISTOLOGY
    Aggarwal, Dipanshu
    Pallavi, Kriti
    Narasimhan, Shashank
    Tyagi, Varun Kumar
    [J]. ACTA BIOCLINICA, 2024, 14 (27): : 280 - 290
  • [47] Diagnostic accuracy of the implant stability quotient in monitoring progressive peri-implant bone loss: An experimental study in dogs
    Monje, Alberto
    Insua, Angel
    Monje, Florencio
    Munoz, Fernando
    Salvi, Giovanni E.
    Buser, Daniel
    Chappuis, Vivianne
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2018, 29 (10) : 1016 - 1024
  • [48] Influence of forces on peri-implant bone
    Isidor, Flemming
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2006, 17 : 8 - 18
  • [49] Titanium implant with nanostructured zirconia surface promotes maturation of peri-implant bone in osseointegration
    Dusad, Anand
    Chakkalakal, Dennis A.
    Namavar, Fereydoon
    Haider, Hani
    Hanisch, Brock
    Duryee, Michael J.
    Diaz, April
    Rensch, Adam
    Zhang, Yijia
    Hess, Ryan
    Thiele, Geoffrey M.
    Fehringer, Edward V.
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2013, 227 (H5) : 510 - 522
  • [50] Influence of Implant Neck Design on Peri-Implant Tissue Dimensions: A Comparative Study in Dogs
    Luis Calvo-Guirado, Jose
    Jimenez-Soto, Raul
    Perez Albacete-Martinez, Carlos
    Fernandez-Dominguez, Manuel
    Alexandre Gehrke, Sergio
    Eduardo Mate-Sanchez de Val, Jose
    [J]. MATERIALS, 2018, 11 (10)