Effects of implant geometry, surface properties, and TGF-β1 on peri-implant bone response: an experimental study in goats

被引:23
|
作者
Schouten, C. [1 ]
Meijer, G. J. [1 ]
van den Beucken, J. J. J. P. [1 ]
Spauwen, P. H. M. [2 ]
Jansen, J. A. [1 ]
机构
[1] Radboud Univ Nijmegen, Med Ctr, Dept Periodontol & Biomat, NL-6525 ED Nijmegen, Netherlands
[2] Radboud Univ Nijmegen, Med Ctr, Dept Plast & Reconstruct Surg, NL-6525 ED Nijmegen, Netherlands
关键词
calcium phosphate coating; electrostatic spray deposition; goat study; implant design; TGF-beta; 1; ELECTROSTATIC SPRAY DEPOSITION; CALCIUM-PHOSPHATE COATINGS; GROWTH-FACTOR-BETA; OSSEOINTEGRATED TITANIUM IMPLANTS; COATED IMPLANTS; BIOLOGICAL-ACTIVITY; CHEMICAL-PROPERTIES; BIOACTIVE GLASS; DENTAL IMPLANTS; TRABECULAR BONE;
D O I
10.1111/j.1600-0501.2008.01657.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Despite the high success rates in implantology, the desire to use oral implants in more challenging clinical situations drives the need for continuing refinements in implant design and surface properties. In the present study, the effect of implant geometry on implant bone response was evaluated using two geometrically different implant types, i.e. screw type (St) and push-in type(Pi). Furthermore, the potential beneficial effect of an electrosprayed calcium phosphate (CaP) coating, either or not enriched with the osteoinductive growth factor TGF-beta 1, on the osteogenic response was examined. A total of 54 implants, divided into six groups (n=9), were inserted into the femoral condyles of nine goats. After an implantation period of 12 weeks, retrieved specimens were evaluated histologically and histomorphometrically. Measurements were statistically evaluated using SPSS 14.0 and analyzed using a linear regression model. With respect to implant design, St-implants showed an overall superior biological healing response compared with Pi-implants. Considering surface properties, the deposition of an electrosprayed CaP (2-3 mu m) coating onto implants significantly increased the amount of bone-implant contact for both implant types. Additional enrichment of the CaP coating with the osteoinductive growth factor TGF-beta 1 did not significantly affect peri-implant bone response. The results of this study indicate that a substantial improvement of the osteogenic response to titanium implants can be achieved by the deposition of an electrosprayed CaP coating. The enrichment of the coating with 1 mu g TGF-beta 1 has only a marginal effect. To cite this article:Schouten C, Meijer GJ, van den Beucken JJJP, Spauwen PHM, Jansen JA. Effects of implant geometry, surface properties and TGF-beta 1 on peri-implant bone response: an experimental study in goats.Clin. Oral Impl. Res. 20, 2009; 421-429.doi: 10.1111/j.1600-0501.2008.01657.x.
引用
收藏
页码:421 / 429
页数:9
相关论文
共 50 条
  • [1] Peri-implant bone response to orthodontic loading: Part 1. A histomorphometric study of the effects of implant surface design
    Oyonarte, R
    Pilliar, RM
    Deporter, D
    Woodside, DG
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2005, 128 (02) : 173 - 181
  • [2] Effect of implant surface properties on peri-implant bone healing: a histological and histomorphometric study in dogs
    Al-Hamdan, Khalid
    Al-Moaber, Samar H.
    Junker, Rudiger
    Jansen, John A.
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2011, 22 (04) : 399 - 405
  • [3] Effect of Implant Surface Properties on Peri-Implant Bone Healing: Implant Stability and Microcomputed Tomographic Analysis
    Al-Moaber, Samar H.
    Al-Hamdan, Khalid
    Junker, Rudiger
    Jansen, John A.
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2012, 27 (01) : 77 - 83
  • [4] Effects of implant geometry and surface modifications on implant bone response
    Schouten, C.
    Meijer, G. J.
    Jansen, J. A.
    [J]. TISSUE ENGINEERING, 2007, 13 (07): : 1682 - 1682
  • [5] Role of the surface in peri-implant bone biology
    Lopez-Valverde, Antonio
    Borges, Tiago
    Vale, Francisco
    De Sousa, Bruno Macedo
    [J]. FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2023, 11
  • [6] Peri-implant bone response to orthodontic loading: Part 2. Implant surface geometry and its effect on regional bone remodeling
    Oyonarte, R
    Pilliar, RM
    Deporter, D
    Woodside, DG
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2005, 128 (02) : 182 - 189
  • [7] Effect of implant surface roughness and loading on peri-implant bone formation
    Vandamme, Katleen
    Naert, Ignace
    Sloten, Jozef Vander
    Puers, Robert
    Duyck, Joke
    [J]. JOURNAL OF PERIODONTOLOGY, 2008, 79 (01) : 150 - 157
  • [8] Effects of alendronate on the peri-implant bone in rats
    Oh, K. C.
    Moon, H. S.
    Lee, J. H.
    Park, Y. B.
    Kim, J-H
    [J]. ORAL DISEASES, 2015, 21 (02) : 248 - 256
  • [9] Effects of Peri-implant Mucosal Characteristics on Clinical Peri-implant Parameters: A Retrospective Study
    Bozkurt, Esra
    Uslu, Mustafa Ozay
    [J]. MEANDROS MEDICAL AND DENTAL JOURNAL, 2023, 24 (02): : 105 - 111
  • [10] Local tissue effects and peri-implant bone healing induced by implant surface treatment: an in vivo study in the sheep
    Rousseau, Nicolas
    Msolli, Ines
    Chabrand, Patrick
    Destainville, Arnaud
    Richart, Olivier
    Milan, Jean-Louis
    [J]. JOURNAL OF PERIODONTAL RESEARCH, 2021, 56 (04) : 789 - 803