pH-Dependent Equilibrium Isotope Fractionation Associated with the Compound Specific Nitrogen and Carbon Isotope Analysis of Substituted Anilines by SPME-GC/IRMS

被引:47
|
作者
Skarpeli-Liati, Marita [1 ,2 ]
Turgeon, Aurora [4 ,5 ]
Garr, Ashley N. [4 ,5 ]
Arnold, William A. [3 ]
Cramer, Christopher J. [4 ,5 ]
Hofstetter, Thomas B. [1 ,2 ]
机构
[1] Eawag, Swiss Fed Inst Aquat Sci & Technol, CH-8600 Dubendorf, Switzerland
[2] Swiss Fed Inst Technol, Inst Biogeochem & Pollutant Dynam IBP, CH-8092 Zurich, Switzerland
[3] Univ Minnesota, Dept Civil Engn, Minneapolis, MN 55455 USA
[4] Univ Minnesota, Dept Chem, Minneapolis, MN 55455 USA
[5] Univ Minnesota, Inst Supercomp, Minneapolis, MN 55455 USA
基金
瑞士国家科学基金会;
关键词
VOLATILE ORGANIC-COMPOUNDS; RATIO MASS-SPECTROMETRY; AROMATIC-AMINES; ANAEROBIC BIODEGRADATION; NITROAROMATIC COMPOUNDS; DEGRADATION PATHWAYS; CHROMATOGRAPHY; MTBE; TRANSFORMATION; CONTAMINATION;
D O I
10.1021/ac102667y
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Solid-phase microextraction (SPME) coupled to gas chromatography/isotope ratio mass spectrometry (GC/IRMS) was used to elucidate the effects of N-atom protonation on the analysis of N and C isotope signatures of selected aromatic amines. Precise and accurate isotope ratios were measured using polydimethylsiloxane/divinylbenzene (PDMS/DVB) as the SPME fiber material at solution pH-values that exceeded the pK(a) of the substituted aniline's conjugate acid by two pH-units. Deviations of (delta(15)N and delta(13)C-values from reference measurements by elemental analyzer IRMS were small (<0.9 parts per thousand) and within the typical uncertainties of isotope ratio measurements by SPME-GC/IRMS. Under these conditions, the detection limits for accurate isotope ratio measurements were between 0.64 and 2.1 mg L(-1) for delta(15)N and between 0.13 and 0.54 mg L(-1) for delta(13)C, respectively. Substantial inverse N isotope fractionation was observed by SPME-GC/IRMS as the fraction of protonated species increased with decreasing pH leading to deviations of -20 parts per thousand while the corresponding delta(13)C-values were largely invariant. From isotope ratio analysis at different solution pHs and theoretical calculations by density functional theory, we derived equilibrium isotope effects, EIEs, pertinent to aromatic amine protonation of 0.980 and 1.001 for N and C, respectively, which were very similar for all compounds investigated. Our work shows that N-atom protonation can compromise accurate compound-specific N isotope analysis of aromatic amines.
引用
收藏
页码:1641 / 1648
页数:8
相关论文
共 25 条
  • [21] A reliable compound-specific nitrogen isotope analysis of amino acids by GC-C-IRMS following derivatisation into N-pivaloyl-iso-propyl (NPIP)esters for high-resolution food webs estimation
    Zhang, Zhongyi
    Tian, Jing
    Xiao, Hongwei
    Zheng, Nengjian
    Gao, Xiaofei
    Zhu, Renguo
    Xiao, Huayun
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2016, 1033 : 382 - 389
  • [22] A novel high-temperature combustion interface for compound-specific stable isotope analysis of carbon and nitrogen via high-performance liquid chromatography/isotope ratio mass spectrometry
    Federherr, E.
    Willach, S.
    Roos, N.
    Lange, L.
    Molt, K.
    Schmidt, T. C.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2016, 30 (07) : 944 - 952
  • [23] Compound-Specific Carbon, Nitrogen, and Hydrogen Isotope Analysis to Characterize Aerobic Biodegradation of 2,3-Dichloroaniline by a Mixed Enrichment Culture
    Suchana, Shamsunnahar
    Araujo, Sofia Pimentel
    Lomheim, Line
    Mack, E. Erin
    Spain, Jim C.
    Edwards, Elizabeth
    Passeport, Elodie
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2024, : 12042 - 12050
  • [24] Development and Validation of an Universal Interface for Compound-Specific Stable Isotope Analysis of Chlorine (37Cl/35Cl) by GC-High-Temperature Conversion (HTC)-MS/IRMS
    Renpenning, Julian
    Hitzfeld, Kristina L.
    Gilevska, Tetyana
    Nijenhuis, Ivonne
    Gehre, Matthias
    Richnow, Hans-Hermann
    ANALYTICAL CHEMISTRY, 2015, 87 (05) : 2832 - 2839
  • [25] Extraction and derivatization of absorbed lipid residues from very small and very old samples of ceramic potsherds for molecular analysis by gas chromatography-mass spectrometry (GC-MS) and single compound stable carbon isotope analysis by gas chromatography-combustion-isotope ratio mass spectrometry (GC-C-IRMS)
    Papakosta, Vasiliki
    Smittenberg, Rienk H.
    Gibbs, Kevin
    Jordan, Peter
    Isaksson, Sven
    MICROCHEMICAL JOURNAL, 2015, 123 : 196 - 200