Improving High-resolution Impedance Manometry Using Novel Viscous and Super-viscous Substrates in the Supine and Upright Positions: A Pilot Study

被引:6
|
作者
Wong, Uni [1 ,2 ]
Person, Erik B. [1 ,2 ]
Castell, Donald O. [3 ]
von Rosenvinge, Erik [1 ,2 ]
Raufman, Jean-Pierre [1 ,2 ]
Xie, Guofeng [1 ,2 ]
机构
[1] Univ Maryland, Sch Med, Div Gastroenterol & Hepatol, 22 South Greene St, Baltimore, MD 21201 USA
[2] Vet Affairs Maryland Hlth Care Syst, Baltimore, MD USA
[3] Med Univ South Carolina, Coll Med, Div Gastroenterol & Hepatol, Charleston, SC 29425 USA
关键词
Esophageal motility disorders; Manometry; Viscous substrates; ESOPHAGEAL MOTILITY DISORDERS; INCOMPLETE BOLUS CLEARANCE; CHICAGO CLASSIFICATION; PRESSURE TOPOGRAPHY; DIAGNOSIS; CRITERIA; LIQUID;
D O I
10.5056/jnm18010
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background/Aims Swallows with viscous or solid boluses in different body positions alter esophageal manometry patterns. Limitations of previous studies include lack of standardized viscous substrates and the need for chewing prior to swallowing solid boluses. We hypothesize that high-resolution impedance manometry (HRiM) using standardized viscous and super-viscous swallows in supine and upright positions improves sensitivity for detecting esophageal motility abnormalities when compared with traditional saline swallows. To establish normative values for these novel substrates, we recruited healthy volunteers and performed HRiM. Methods Standardized viscous and super-viscous substrates were prepared using "Thick-It" food thickener and a rotational viscometer. All swallows were administered in 5-mL increments in both supine and upright positions. HRiM metrics and impedance (bolus transit) were calculated. We used a paired two-tailed t test to compare all metrics by position and substrate. Results The 5-g, 7-g, and 10-g substrates measured 5000, 36 200, and 64 700 mPa.sec, respectively. In 18 volunteers, we observed that the integrated relaxation pressure was lower when upright than when supine for all substrates (P < 0.01). The 10-g substrate significantly increased integrated relaxation pressure when compared to saline in the supine position (P < 0.01). Substrates and positions also affected distal contractile integral, distal latency, and impedance values. Conclusions We examined HRiM values using novel standardized viscous and super-viscous substrates in healthy subjects for both supine and upright positions. We found that viscosity and position affected HRiM Chicago metrics and have potential to increase the sensitivity of esophageal manometry.
引用
收藏
页码:570 / 576
页数:7
相关论文
共 42 条
  • [41] Oropharyngeal Risk Index of Three-Dimensional Volume of Inverted Impedance (ORIV), a Novel Method to Estimate Oropharyngeal Abnormality: Based on Comparison Between Oropharyngeal Cancer and Asymptomatic Normal Controls Using High-Resolution Impedance Manometry
    Jung, Kee Wook
    Joo, Segyeong
    Jung, Hwoon-Yong
    Myung, Seung-Jae
    Kim, Dong Kyu
    Choi, Kyoung Hyo
    Choi, Seung-Ho
    Roh, Jong-Lyel
    Nam, Soon Yuhl
    Kim, Sang Woon
    Ryu, Chang Hwan
    Kwon, Miseon
    Yoon, In Ja
    Seo, So Young
    Koo, Hyun Sook
    Choi, Kee Don
    Song, Ho June
    Lee, Gin Hyug
    Murray, Joseph A.
    Romero, Yvonne
    Kim, Jin-Ho
    GASTROENTEROLOGY, 2013, 144 (05) : S786 - S787
  • [42] Elimination of Intracanal Tissue and Debris through a Novel Laser-activated System Assessed Using High-resolution Micro-computed Tomography: A Pilot Study
    Lloyd, Adam
    Uhles, Jonathan P.
    Clement, David J.
    Garcia-Godoy, Franklin
    JOURNAL OF ENDODONTICS, 2014, 40 (04) : 584 - 587