Improving High-resolution Impedance Manometry Using Novel Viscous and Super-viscous Substrates in the Supine and Upright Positions: A Pilot Study

被引:6
|
作者
Wong, Uni [1 ,2 ]
Person, Erik B. [1 ,2 ]
Castell, Donald O. [3 ]
von Rosenvinge, Erik [1 ,2 ]
Raufman, Jean-Pierre [1 ,2 ]
Xie, Guofeng [1 ,2 ]
机构
[1] Univ Maryland, Sch Med, Div Gastroenterol & Hepatol, 22 South Greene St, Baltimore, MD 21201 USA
[2] Vet Affairs Maryland Hlth Care Syst, Baltimore, MD USA
[3] Med Univ South Carolina, Coll Med, Div Gastroenterol & Hepatol, Charleston, SC 29425 USA
关键词
Esophageal motility disorders; Manometry; Viscous substrates; ESOPHAGEAL MOTILITY DISORDERS; INCOMPLETE BOLUS CLEARANCE; CHICAGO CLASSIFICATION; PRESSURE TOPOGRAPHY; DIAGNOSIS; CRITERIA; LIQUID;
D O I
10.5056/jnm18010
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background/Aims Swallows with viscous or solid boluses in different body positions alter esophageal manometry patterns. Limitations of previous studies include lack of standardized viscous substrates and the need for chewing prior to swallowing solid boluses. We hypothesize that high-resolution impedance manometry (HRiM) using standardized viscous and super-viscous swallows in supine and upright positions improves sensitivity for detecting esophageal motility abnormalities when compared with traditional saline swallows. To establish normative values for these novel substrates, we recruited healthy volunteers and performed HRiM. Methods Standardized viscous and super-viscous substrates were prepared using "Thick-It" food thickener and a rotational viscometer. All swallows were administered in 5-mL increments in both supine and upright positions. HRiM metrics and impedance (bolus transit) were calculated. We used a paired two-tailed t test to compare all metrics by position and substrate. Results The 5-g, 7-g, and 10-g substrates measured 5000, 36 200, and 64 700 mPa.sec, respectively. In 18 volunteers, we observed that the integrated relaxation pressure was lower when upright than when supine for all substrates (P < 0.01). The 10-g substrate significantly increased integrated relaxation pressure when compared to saline in the supine position (P < 0.01). Substrates and positions also affected distal contractile integral, distal latency, and impedance values. Conclusions We examined HRiM values using novel standardized viscous and super-viscous substrates in healthy subjects for both supine and upright positions. We found that viscosity and position affected HRiM Chicago metrics and have potential to increase the sensitivity of esophageal manometry.
引用
收藏
页码:570 / 576
页数:7
相关论文
共 42 条
  • [31] Swallowing function evaluation using high-resolution impedance manometry in patients undergoing anterior cervical discectomy and fusion: A case series study
    Lai, Chih-jun
    Tsuang, Fon-Yih
    NEUROGASTROENTEROLOGY AND MOTILITY, 2020, 32
  • [32] Relationship Between Tongue Pressure and Pharyngeal Function Assessed Using High-Resolution Manometry in Older Dysphagia Patients with Sarcopenia: A Pilot Study
    Kunieda, Kenjiro
    Fujishima, Ichiro
    Wakabayashi, Hidetaka
    Ohno, Tomohisa
    Shigematsu, Takashi
    Itoda, Masataka
    Oshima, Fumiko
    Mori, Takashi
    Ogawa, Nami
    Ogawa, Sumito
    DYSPHAGIA, 2021, 36 (01) : 33 - 40
  • [33] Relationship Between Tongue Pressure and Pharyngeal Function Assessed Using High-Resolution Manometry in Older Dysphagia Patients with Sarcopenia: A Pilot Study
    Kenjiro Kunieda
    Ichiro Fujishima
    Hidetaka Wakabayashi
    Tomohisa Ohno
    Takashi Shigematsu
    Masataka Itoda
    Fumiko Oshima
    Takashi Mori
    Nami Ogawa
    Sumito Ogawa
    Dysphagia, 2021, 36 : 33 - 40
  • [34] The effects of artificial tears on the tear film using a novel, high-resolution tear film imager: a pilot study
    Tessone, Isaac M.
    Antman, Gal
    Rios, Hernan
    Ahsanuddin, Sofia
    MuncharazDuran, Luis
    Vercellin, Alice Chandra Verticchio
    Siesky, Brent A.
    Kellner, Rebecca
    Sidoti, Paul A.
    Chen, Masako
    Ritzer, Lukas
    Mordechaev, Emanuel
    Moy, Ethan
    Chui, Toco Y. P.
    Rosen, Richard B.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (08)
  • [35] Gastric Accommodation Testing Using Hybrid Nuclear Imaging Volumetry and Combined High-Resolution Manometry-Nutrient Drink Test: A Pilot Study in Healthy Individuals
    Tagiling, Nashrulhaq
    Lee, Yeong Yeh
    Rohani, Mohd Fazrin Mohd
    Udin, Muhamad Yusri
    Aziz, Azliani Abdul
    Muhamad, Siti Norhasliza
    Musarudin, Marianie
    Razab, Mohammad Khairul Azhar Abdul
    Zainol, Nurul Ain Shafiqah
    Tan, Phei Oon
    Mat Nawi, Norazlina
    NEUROGASTROENTEROLOGY AND MOTILITY, 2025,
  • [36] Impaired Bolus Transit of Esophageal Swallows May Play an Important Role in Eliciting Non-Cardiac Chest Pain: A Study Using High-Resolution Impedance Manometry
    Min, Yang Won
    Lee, Ji Young
    Kim, Eun Ran
    Min, Byung-Hoon
    Lee, Jun Haeng
    Kim, Jae J.
    Rhee, Jong Chul
    Rhee, Poong-Lyul
    GASTROENTEROLOGY, 2013, 144 (05) : S786 - S786
  • [37] Three-dimensional volume of inverted impedance (VII): a novel method to measure bolus transit using high-resolution impedance manometry and its relationship to key parameters of the Chicago classification based on an asymptomatic normal population
    Jung, K. W.
    Joo, S. G.
    Jung, H. -Y.
    Myung, S. -J.
    Choi, K. D.
    Song, H. J.
    Lee, G. H.
    Kim, J. -H.
    NEUROGASTROENTEROLOGY AND MOTILITY, 2013, 25 : 31 - 31
  • [38] Three-Dimensional Volume of Inverted Impedance (VII): A Novel Method to Measure Bolus Transit Using High-Resolution Impedance Manometry and Its Relationship to Key Parameters of the Chicago Classification Based on an Asymptomatic Normal Population
    Jung, Kee Wook
    Joo, Segyeong
    Jung, Hwoon-Yong
    Myung, Seung-Jae
    Yoon, In Ja
    Seo, So Young
    Koo, Hyun Sook
    Choi, Kee Don
    Song, Ho June
    Lee, Gin Hyug
    Murray, Joseph A.
    Romero, Yvonne
    Kim, Jin-Ho
    GASTROENTEROLOGY, 2013, 144 (05) : S260 - S260
  • [39] In vivo pilot study into superficial microcirculatory characteristics of colorectal adenomas using novel high-resolution magnifying endoscopy with blue laser imaging
    Dong, Hai-Bin
    Chen, Tao
    Zhang, Xiao-Fei
    Ren, Yu-Tang
    Jiang, Bo
    WORLD JOURNAL OF GASTROINTESTINAL ENDOSCOPY, 2024, 16 (04):
  • [40] Oropharyngeal risk index of three-dimensional volume of inverted impedance (ORIV), a novel method to estimate oropharyngeal abnormality: based on comparison between oropharyngeal cancer and asymptomatic normal controls using high-resolution impedance manometry
    Jung, K. W.
    Joo, S. G.
    Jung, H. -Y.
    Myung, S. -J.
    Choi, K. D.
    Song, H. J.
    Lee, G. H.
    Kim, J. -H.
    NEUROGASTROENTEROLOGY AND MOTILITY, 2013, 25 : 31 - 31