Feasibility of dose painting using volumetric modulated arc optimization and delivery

被引:45
|
作者
Korreman, Stine S. [1 ,2 ,4 ]
Ulrich, Silke
Bowen, Steve [3 ]
Deveau, Michael [3 ]
Bentzen, Soren M. [2 ]
Jeraj, Robert [2 ,3 ,5 ]
机构
[1] Rigshosp, Dept Radiat Oncol, Finsen Ctr, Sect 3994, DK-2100 Copenhagen O, Denmark
[2] Univ Wisconsin, Dept Human Oncol, Sch Med & Publ Hlth, Ctr Clin Sci, Madison, WI USA
[3] Univ Wisconsin, Dept Med Phys, Sch Med & Publ Hlth, Madison, WI 53706 USA
[4] Univ Copenhagen, Niels Bohr Inst, DK-2100 Copenhagen, Denmark
[5] Jozef Stefan Inst, Ljubljana 1000, Slovenia
关键词
TUMOR-CONTROL PROBABILITY; RADIATION-THERAPY; HETEROGENEOUS TUMORS; NECK-CANCER; RADIOTHERAPY; HYPOXIA; HEAD; PRESCRIPTION; BIOLOGY; IMPT;
D O I
10.3109/0284186X.2010.498440
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose. Dose painting strategies are limited by optimization algorithms in treatment planning systems and physical constraints of the beam delivery. We investigate dose conformity using the RapidArc optimizer and beam delivery technique. Furthermore, robustness of the plans with respect to positioning uncertainties are evaluated. Methods. A head & neck cancer patient underwent a [Cu-61]Cu-ATSM PET/CT-scan. PET-SUVs were converted to prescribed dose with a base dose of 60 Gy, and target mean dose 90 Gy. The voxel-based prescription was converted into 3, 5, 7, 9, and 11 discrete prescription levels. Optimization was performed in Eclipse, varying the following parameters: MLC leaf width (5 mm and 2.5 mm), number of arcs (1 and 2) and collimator rotation (0, 15, 30 and 45 degrees). Dose conformity was evaluated using quality volume histograms (QVHs), and relative volumes receiving within +5% of prescribed dose (Q(0.95-1.05)). Deliverability was tested using a Delta4 (R) phantom. Robustness was tested by shifting the isocenter 1 mm and 2 mm in all directions, and recalculating the dose. Results. Good conformity was obtained using MLC leaf width 2.5 mm, two arcs, and collimators 45/315 degrees, with Q(0.95-1.05)=92.8%, 91.6%, 89.7% and 84.6%. Using only one arc or increasing the MLC leaf width had a small deteriorating effect of 2 5%. Small changes in collimator angle gave small changes, but large changes in collimator angle gave a larger decrease in plan conformity; for angles of 15 and 0 degrees (two arcs, 2.5 mm leaf width), Q(0.95-1.05) decreased by up to 15%. Consistency between planned and delivered dose was good, with similar to 90% of gamma values <1. For 1 mm shift, Q(0.95-1.05) was decreased by 5-15%, while for 2 mm shift, Q(0.95-1.05) was decreased to 55-60%. Conclusions. Results demonstrate feasibility of planning of prescription doses with multiple levels for dose painting using RapidArc, and plans were deliverable. Robustness to positional error was low.
引用
收藏
页码:964 / 971
页数:8
相关论文
共 50 条
  • [21] Initial Experience with the Delivery of Volumetric Modulated Arc Therapy
    Shepard, D. M.
    Cao, D.
    Afghan, M. K. N.
    [J]. MEDICAL PHYSICS, 2008, 35 (06)
  • [22] AN ANALYSIS OF ACCURACY OF DOSE USING THE COMPSS PROGRAM IN VOLUMETRIC MODULATED ARC THERAPY
    Huh, H. D.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S507 - S507
  • [23] Dose Effect of Delivery Errors On Volumetric Modulated Arc Therapy for Nasopharynx Cancer and Cervical Cancer
    Bai, S.
    Yuan, Q.
    Li, G.
    [J]. MEDICAL PHYSICS, 2019, 46 (06) : E638 - E638
  • [24] VOLUMETRIC MODULATED INTENSITY MODULATED ARC THERAPY FOR STEREOTACTIC LUNG RADIOTHERAPY: CONSTANT DOSE RATE VERSUS VARIABLE DOSE RATE DELIVERY
    Dogan, N.
    Wu, Y.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S499 - S499
  • [25] Optimization approaches to volumetric modulated arc therapy planning
    Unkelbach, Jan
    Bortfeld, Thomas
    Craft, David
    Alber, Markus
    Bangert, Mark
    Bokrantz, Rasmus
    Chen, Danny
    Li, Ruijiang
    Xing, Lei
    Men, Chunhua
    Nill, Simeon
    Papp, David
    Romeijn, Edwin
    Salari, Ehsan
    [J]. MEDICAL PHYSICS, 2015, 42 (03) : 1367 - 1377
  • [26] Direct leaf trajectory optimization for volumetric modulated arc therapy planning with sliding window delivery
    Papp, David
    Unkelbach, Jan
    [J]. MEDICAL PHYSICS, 2014, 41 (01)
  • [27] Collimator Angle Optimization in Volumetric Modulated Arc Therapy
    Andersen, A.
    Johnson, C.
    Bartlett, G.
    Das, I.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3627 - 3627
  • [28] Feasibility of Four-dimensional Adaptation of Volumetric Modulated Arc Therapy Based on Volumetric Modulated Arc Therapy-computed Tomography
    Zhao, Xiaodong
    Zhang, Rui
    [J]. JOURNAL OF MEDICAL PHYSICS, 2023, 48 (02) : 154 - 160
  • [29] An algorithm to calculate a collapsed arc dose matrix in volumetric modulated arc therapy
    Arumugam, Sankar
    Xing, Aitang
    Jameson, Michael
    Holloway, Lois
    [J]. MEDICAL PHYSICS, 2013, 40 (07)
  • [30] A Method to Ensure Consistent Delivery of Volumetric Modulated Arc Therapy
    Stenbeck, J.
    Alkhatib, H.
    Gebreamlak, W.
    Oves, S.
    Fontenot, J.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (03): : S791 - S791