Feasibility of Four-dimensional Adaptation of Volumetric Modulated Arc Therapy Based on Volumetric Modulated Arc Therapy-computed Tomography

被引:0
|
作者
Zhao, Xiaodong [1 ]
Zhang, Rui [2 ,3 ]
机构
[1] Washington Univ St Louis, Dept Radiat Oncol, St Louis, MO USA
[2] Louisiana State Univ, Dept Phys & Astron, Baton Rouge, LA 70803 USA
[3] Mary Bird Perkins Canc Ctr, Dept Radiat Oncol, Baton Rouge, LA USA
基金
美国国家卫生研究院;
关键词
Adaptive radiotherapy; computed tomography; four-dimensional; volumetric modulated arc therapy; CELL LUNG-CANCER; BODY RADIATION-THERAPY; DOSE-ESCALATED RADIOTHERAPY; STEREOTACTIC RADIOTHERAPY; CONFORMAL RADIOTHERAPY; THORACIC RADIOTHERAPY; ADAPTIVE RADIOTHERAPY; TOXICITY; TRIAL; SURVIVAL;
D O I
10.4103/jmp.jmp_24_23
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Volumetric modulated arc therapy (VMAT) has been increasingly used for cancer patients due to the fast delivery and improved dose conformity. Adaptive radiotherapy (ART) can significantly decrease dose to normal tissues and allow for dose escalation. However, current imaging techniques cannot provide four-dimensional (4D) patient anatomy or dose information during VMAT, which is critical for ART that involves respiratory motion. A novel imaging tool named VMAT-computed tomography (VMAT-CT) has the potential to reveal intra-fractional patient information. The goal of this study was to evaluate the feasibility of 4D adaptive VMAT based on 4D VMAT-CT. Materials and Methods: A commercial QUASAR respiratory phantom and an in-house deformable lung phantom were used in this study, and lung VMAT plans, including 4D union plan and 4D ART plan, were generated for the phantoms. A real lung patient's plan was also used in this feasibility study. ART plans based on 4D VMAT-CT were created for the phantoms and the real patient when planning goals were not met. Dose escalation plan based on 4D VMAT-CT was also created for the real patient. Results: Planning target volume (PTV) coverage for the QUASAR phantom was 85.5% after breathing pattern being changed, and went up to 95% after adaptive re-planning. PTV coverage for the deformable phantom was 93% after deformation and breathing pattern being changed, and went up to 95% after re-planning. Re-planning and dose escalation were feasible and can spare normal tissues for the real patient. 4D ART plan based on 4D VMAT-CT required smaller margins than 4D union plan while maintaining the same prescription dose coverage. Conclusions: ART based on 4D VMAT-CT is feasible and would potentially facilitate re-planning and PTV dose escalation for VMAT patients who have the motion issue.
引用
收藏
页码:154 / 160
页数:7
相关论文
共 50 条
  • [1] Inverse Planning for Four-dimensional Volumetric Modulated ARC Therapy
    Ma, Y.
    Xing, L.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S766 - S766
  • [2] Four-Dimensional Dose Reconstruction for Lung Cancer in Volumetric Modulated Arc Therapy
    Hashimoto, M.
    Ito, Y.
    Takahashi, R.
    Nakajima, M.
    Matsubayashi, F.
    Saotome, S.
    Kitamura, N.
    Sato, T.
    Kozuka, T.
    Oguchi, M.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (02): : E611 - E611
  • [3] Volumetric Modulated Arc Therapy
    Shepard, D.
    Popple, R.
    [J]. MEDICAL PHYSICS, 2013, 40 (06)
  • [4] Volumetric Modulated Arc Therapy
    Shepard, D.
    Popple, R.
    [J]. MEDICAL PHYSICS, 2012, 39 (06) : 3858 - 3858
  • [5] Inverse planning for four-dimensional (4D) volumetric modulated arc therapy
    Ma, Yunzhi
    Chang, Daniel
    Keall, Paul
    Xie, Yiaoqin
    Park, Jae-yoon
    Suh, Tae-Suk
    Xing, Lei
    [J]. MEDICAL PHYSICS, 2010, 37 (11) : 5627 - 5633
  • [6] Paraspinal volumetric modulated arc therapy
    Bedford, J. L.
    Convery, H. M.
    Hansen, V. N.
    Saran, F. H.
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2012, 85 (1016): : 1128 - 1133
  • [7] Three-dimensional versus four-dimensional dose calculation for volumetric modulated arc therapy of hypofractionated treatments
    Ehrbar, Stefanie
    Lang, Stephanie
    Stieb, Sonja
    Riesterer, Oliver
    Stark, Luisa Sabrina
    Guckenberger, Matthias
    Kloeck, Stephan
    [J]. ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2016, 26 (01): : 45 - 53
  • [8] Volumetric Modulated Arc Therapy for Advanced Pancreatic Cancer„Volumetric modulated arc therapy“ bei lokal fortgeschrittenem Pankreaskarzinom
    Wietse Eppinga
    Frank Lagerwaard
    Wilko Verbakel
    Ben Slotman
    Suresh Senan
    [J]. Strahlentherapie und Onkologie, 2010, 186 (7) : 382 - 387
  • [9] Treatment planning for volumetric modulated arc therapy
    Bedford, James L.
    [J]. MEDICAL PHYSICS, 2009, 36 (11) : 5128 - 5138
  • [10] Portal Imaging for Volumetric Modulated Arc Therapy
    Burman, C.
    Li, J.
    Chan, M.
    [J]. MEDICAL PHYSICS, 2009, 36 (06)