Feasibility of dose painting using volumetric modulated arc optimization and delivery

被引:45
|
作者
Korreman, Stine S. [1 ,2 ,4 ]
Ulrich, Silke
Bowen, Steve [3 ]
Deveau, Michael [3 ]
Bentzen, Soren M. [2 ]
Jeraj, Robert [2 ,3 ,5 ]
机构
[1] Rigshosp, Dept Radiat Oncol, Finsen Ctr, Sect 3994, DK-2100 Copenhagen O, Denmark
[2] Univ Wisconsin, Dept Human Oncol, Sch Med & Publ Hlth, Ctr Clin Sci, Madison, WI USA
[3] Univ Wisconsin, Dept Med Phys, Sch Med & Publ Hlth, Madison, WI 53706 USA
[4] Univ Copenhagen, Niels Bohr Inst, DK-2100 Copenhagen, Denmark
[5] Jozef Stefan Inst, Ljubljana 1000, Slovenia
关键词
TUMOR-CONTROL PROBABILITY; RADIATION-THERAPY; HETEROGENEOUS TUMORS; NECK-CANCER; RADIOTHERAPY; HYPOXIA; HEAD; PRESCRIPTION; BIOLOGY; IMPT;
D O I
10.3109/0284186X.2010.498440
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose. Dose painting strategies are limited by optimization algorithms in treatment planning systems and physical constraints of the beam delivery. We investigate dose conformity using the RapidArc optimizer and beam delivery technique. Furthermore, robustness of the plans with respect to positioning uncertainties are evaluated. Methods. A head & neck cancer patient underwent a [Cu-61]Cu-ATSM PET/CT-scan. PET-SUVs were converted to prescribed dose with a base dose of 60 Gy, and target mean dose 90 Gy. The voxel-based prescription was converted into 3, 5, 7, 9, and 11 discrete prescription levels. Optimization was performed in Eclipse, varying the following parameters: MLC leaf width (5 mm and 2.5 mm), number of arcs (1 and 2) and collimator rotation (0, 15, 30 and 45 degrees). Dose conformity was evaluated using quality volume histograms (QVHs), and relative volumes receiving within +5% of prescribed dose (Q(0.95-1.05)). Deliverability was tested using a Delta4 (R) phantom. Robustness was tested by shifting the isocenter 1 mm and 2 mm in all directions, and recalculating the dose. Results. Good conformity was obtained using MLC leaf width 2.5 mm, two arcs, and collimators 45/315 degrees, with Q(0.95-1.05)=92.8%, 91.6%, 89.7% and 84.6%. Using only one arc or increasing the MLC leaf width had a small deteriorating effect of 2 5%. Small changes in collimator angle gave small changes, but large changes in collimator angle gave a larger decrease in plan conformity; for angles of 15 and 0 degrees (two arcs, 2.5 mm leaf width), Q(0.95-1.05) decreased by up to 15%. Consistency between planned and delivered dose was good, with similar to 90% of gamma values <1. For 1 mm shift, Q(0.95-1.05) was decreased by 5-15%, while for 2 mm shift, Q(0.95-1.05) was decreased to 55-60%. Conclusions. Results demonstrate feasibility of planning of prescription doses with multiple levels for dose painting using RapidArc, and plans were deliverable. Robustness to positional error was low.
引用
收藏
页码:964 / 971
页数:8
相关论文
共 50 条
  • [1] DOSE PAINTING USING VOLUMETRIC MODULATED ARC OPTIMIZATION AND DELIVERY
    Korreman, S.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2012, 102 : S122 - S122
  • [2] FEASIBILITY OF DOSE PAINTING USING VOLUMETRIC MODULATED ARC (RAPIDARC) OPTIMIZATION
    Korreman, S.
    Ulrich, S.
    Bowen, S.
    Deveau, M.
    Jeraj, R.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S554 - S554
  • [3] DOSE CORRECTION STRATEGY FOR THE OPTIMIZATION OF VOLUMETRIC MODULATED ARC THERAPY
    Mageras, G. S.
    Zhang, P.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2012, 102 : S35 - S35
  • [4] Dose correction strategy for the optimization of volumetric modulated arc therapy
    Zhang, Pengpeng
    Yang, Jie
    Hunt, Margie
    Mageras, Gig
    [J]. MEDICAL PHYSICS, 2010, 37 (06) : 2441 - 2444
  • [5] Continuous aperture dose calculation and optimization for volumetric modulated arc therapy
    Christiansen, Eric
    Heath, Emily
    Xu, Tong
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (21):
  • [6] Dose painting with Volumetric Modulated Arc Therapy (VMAT) can reduce kidney dose in abdominal neuroblastoma
    Pinkham, M. B.
    McWilliam, A.
    Smith, E.
    Chang, Y. C.
    Gattamaneni, H. R.
    Whitfield, G. A.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S686 - S687
  • [7] External beam pulsed low dose radiotherapy using volumetric modulated arc therapy: Planning and delivery
    Tyagi, Neelam
    Yang, Kai
    Sandhu, Raminder
    Yan, Di
    Park, Sean S.
    Chen, Peter Y.
    Marples, Brian
    [J]. MEDICAL PHYSICS, 2013, 40 (01)
  • [8] Feasibility Study of Volumetric Modulated Arc Therapy with Constant Dose Rate for Endometrial Cancer
    Yang, R.
    Wang, J.
    Xu, F.
    Li, H.
    Zhang, X.
    [J]. MEDICAL PHYSICS, 2013, 40 (06)
  • [9] Feasibility Study of Volumetric Modulated Arc Therapy With Constant Dose Rate for Endometrial Cancer
    Yang, R.
    Wang, J.
    Xu, F.
    Li, H.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 87 (02): : S753 - S753
  • [10] Feasibility study of volumetric modulated arc therapy with constant dose rate for endometrial cancer
    Yang, R.
    Wang, J. J.
    Xu, F.
    Li, H.
    Zhang, X. L.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S187 - S188