External beam pulsed low dose radiotherapy using volumetric modulated arc therapy: Planning and delivery

被引:9
|
作者
Tyagi, Neelam [1 ]
Yang, Kai [1 ]
Sandhu, Raminder [1 ]
Yan, Di [1 ]
Park, Sean S. [1 ]
Chen, Peter Y. [1 ]
Marples, Brian [1 ]
机构
[1] William Beaumont Hosp, Dept Radiat Oncol, Royal Oak, MI 48073 USA
关键词
leaf speed; arc length; pulsed low dose RT (PLRT); volumetric modulated arc therapy (VMAT); glioblastomamultiforme (GBM); HYPER-RADIOSENSITIVITY; RETREATMENT STRATEGY; GLIOBLASTOMA; CANCER; IRRADIATION; SURVIVAL; RAPIDARC; QUALITY; IMRT;
D O I
10.1118/1.4769119
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the feasibility of planning and delivering pulsed low dose radiotherapy (PLRT) using volumetric modulated arc therapy (VMAT) on Elektalinacs. Methods: Ten patients previously treated for glioblastomamultiforme (GBM) were replanned using PLRT VMAT to deliver ten 0.2 Gy pulses separated by 3 min intervals with an effective dose rate of 0.067 Gy/min. VMAT parameters such as leaf speed and arc length were investigated to deliver 2 Gy/fraction to a total of 60 Gy to the target volume in ten subfractions or pulses. Plan quality was assessed using conformity and homogeneity indices. Absolute dose distribution for individual pulses was measured using ArcCHECK diode array. Individual pulses were analyzed for reproducibility and stability using machine log files. Machine characteristics at low monitor units and low dose rate were also investigated. Results: An optimal arc length of 140 degrees-160 degrees and a leaf speed of 0.18-0.25 cm/degrees were sufficient to provide equivalent plan coverage and stable delivery. The average time and dose rate required to deliver a single 0.2 Gy pulse was 39.5 +/- 2.3 s and 49 +/- 32.3 cGy/min. Average reductions in MUs for the VMAT PLRT plan compared to IMRT for PTV was 16% (Range: -5.5%-36.1%) and 10.9% (Range: -18.4%-32.3%) for the initial and boost plan. A significant improvement was seen in maximum doses to all sensitive structures when planned with VMAT PLRT. The average absolute dose gamma passing rate for the 10 pulses combined and 2 Gy plan were 91.6 +/- 2.5% and 97.3 +/- 1.2%, respectively. Cumulative monitor units, dose rate, gantry angles, and leaf positions evaluated using machine log files were within 2% for all pulses. Conclusions: Elekta linacs are capable of delivering reproducible and stable PLRT plans. A prospective clinical study employing PLRT is currently in development. (C) 2013 American Association of Physicists in Medicine. [http://dx.doi.org/10.1118/1.4769119]
引用
收藏
页数:9
相关论文
共 50 条
  • [1] External Beam Pulsed Low Dose Radiotherapy Using Volumetric Modulated Arc Therapy: Planning, Delivery and Verification
    Tyagi, N.
    Yang, K.
    Sandhu, R.
    Yan, D.
    [J]. MEDICAL PHYSICS, 2012, 39 (06) : 3997 - 3997
  • [2] Volumetric Modulated Arc Therapy for Spine Radiosurgery: Superior Treatment Planning and Delivery Compared to Static Beam Intensity Modulated Radiotherapy
    Zach, Leor
    Tsvang, Lev
    Alezra, Dror
    Ben Ayun, Maoz
    Harel, Ran
    [J]. BIOMED RESEARCH INTERNATIONAL, 2016, 2016
  • [3] Hippocampal Sparing Radiotherapy Using Intensity Modulated Radiotherapy and Volumetric Modulated Arc Therapy
    Moon, S.
    Kim, D.
    Chung, W.
    Yoon, M.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3437 - 3437
  • [4] DOSE PAINTING USING VOLUMETRIC MODULATED ARC OPTIMIZATION AND DELIVERY
    Korreman, S.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2012, 102 : S122 - S122
  • [5] Potential impact of volumetric modulated arc therapy on the planning and delivery of radiation therapy
    Matuszak, M. M.
    Sui, H.
    Yan, D.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : S651 - S651
  • [6] VOLUMETRIC MODULATED INTENSITY MODULATED ARC THERAPY FOR STEREOTACTIC LUNG RADIOTHERAPY: CONSTANT DOSE RATE VERSUS VARIABLE DOSE RATE DELIVERY
    Dogan, N.
    Wu, Y.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S499 - S499
  • [7] Hippocampal sparing radiotherapy for glioblastoma patients: a planning study using volumetric modulated arc therapy
    Jan Hofmaier
    Steffi Kantz
    Matthias Söhn
    Oliver S. Dohm
    Stefan Bächle
    Markus Alber
    Katia Parodi
    Claus Belka
    Maximilian Niyazi
    [J]. Radiation Oncology, 11
  • [8] Hippocampal sparing radiotherapy for glioblastoma patients: a planning study using volumetric modulated arc therapy
    Hofmaier, Jan
    Kantz, Steffi
    Soehn, Matthias
    Dohm, Oliver S.
    Baechle, Stefan
    Alber, Markus
    Parodi, Katia
    Belka, Claus
    Niyazi, Maximilian
    [J]. RADIATION ONCOLOGY, 2016, 11
  • [9] Volumetric Modulated Arc Therapy for Prostate Radiotherapy
    Moseley, D. J.
    Zhang, B.
    Barnett, E.
    McCann, C.
    Abbas, A.
    Fenkell, L.
    Yeung, I.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S828 - S829
  • [10] A class solution for volumetric-modulated arc therapy planning in postprostatectomy radiotherapy
    Forde, Elizabeth
    Bromley, Regina
    Kneebone, Andrew
    Eade, Thomas
    [J]. MEDICAL DOSIMETRY, 2014, 39 (03) : 261 - 265