Dispersive spread of virtual sources by asymmetric X-ray monochromators

被引:18
|
作者
Huang, X. R. [1 ]
Macrander, A. T. [1 ]
Honnicke, M. G. [2 ,3 ]
Cai, Y. Q. [2 ]
Fernandez, Patricia [1 ]
机构
[1] Argonne Natl Lab, Adv Photon Source, Argonne, IL 60439 USA
[2] Brookhaven Natl Lab, Natl Synchrotron Light Source 2, Upton, NY 11973 USA
[3] Univ Fed Goias, BR-75800000 Jatai, Go, Brazil
关键词
SYNCHROTRON-RADIATION; PERFECT CRYSTALS; OPTICAL-ELEMENTS; SCATTERING; RESOLUTION; DIFFRACTION; BEAMS; DIFFRACTOMETER; REFLECTIONS; COHERENCE;
D O I
10.1107/S0021889812003366
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The principles of the virtual source spread (spatial broadening) phenomenon induced by angular dispersion in asymmetric X-ray Bragg reflections are illustrated, from which the virtual source properties are analyzed for typical high-resolution multiple-crystal monochromators, including inline four-bounce dispersive monochromators, back-reflection-dispersion monochromators and nondispersive nested channel-cut monochromators. It is found that dispersive monochromators can produce spread virtual sources of a few millimetres in size, which may prevent efficient microfocusing of the beam as required by inelastic X-ray scattering spectroscopy and other applications. Possible schemes to mitigate this problem are discussed. The analyses may provide important guidelines for designing and optimizing modern high-precision synchrotron X-ray optics and beamline instrumentation for spectroscopy, imaging and nanofocusing applications.
引用
收藏
页码:255 / 262
页数:8
相关论文