Simultaneous determinations of Cu, Cd and Pb in river-water samples by multielement isotope dilution/ICP-MS with the aid of chelating resin preconcentration

被引:4
|
作者
Yamada, H
Ji, S
Itoh, A
Chiba, K
Haraguchi, H
机构
[1] Nagoya Univ, Grad Sch Engn, Dept Appl Chem, Chikusa Ku, Nagoya, Aichi 4648603, Japan
[2] Nagoya Univ, Waste Treatment Facil, Chikusa Ku, Nagoya, Aichi 4648603, Japan
关键词
river water; multielement isotope dilution analysis; ICP-MS; chelating resin preconcentration; copper; cadmium; lead;
D O I
10.2116/bunsekikagaku.50.433
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The simultaneous determinations of Cu, Cd and Pb in river-water samples were investigated by multielement ID (isotope dilution)/ICP-MS (inductively coupled plasma mass spectrometry). A mixed and enriched spiked solution of Cu (Cu-63, 0.3%; Cu-65, 99.7%), Cd (Cd-110, 0.63%; Cd-111, 96.44%; Cd-112, 1.82%; Cd-113, 0.43%; Cd-114, 0.59%; Cd-116, 0.10%) and Pb (Pb-204, 0.0342%; Pb-206, 92.1497%; Pb-207, 6.5611%; Pb-208, 1.2550%) was added into the river-water samples, and kept standing overnight to achieve isotope equilibria. Since the concentrations of Cu, Cd and Pb in river water were extremely low, they were preconcentrated using a chelating resin (Chelex 100) at pH 9 before an isotope ratio measurement. The isotope ratios of Cu-63/Cu-65, Cd-114/Cd-111 and Pb-208/Pb-206 were then simultaneously measured for the spiked and standard solutions, respectively. Polyatomic ion interferences of (MoO)-Mo-95-O-16 and (MoO)-Mo-98-O-16 with Cd-111 and Cd-114, respectively, could be avoided by chelating resin preconcentration, because Mo was hardly recovered in the preconcentration, while Cd could be recovered by almost 100%. As a consequence, Cu, Cd and Pb in a river-water certified reference material (JAC 0031, issued from the Japan Society for Analytical Chemistry) and a river-water sample collected from the Kiso River were determined with fairly good precision by the present multielement ICP-MS method, simultaneously.
引用
收藏
页码:433 / 439
页数:7
相关论文
共 50 条
  • [31] Determination of Fe, Ni, Cu, Zn, Cd and Pb in seawater by isotope dilution automatic solid-phase extraction-ICP-MS
    Ge, Yuncong
    Zhang, Ruifeng
    Jiang, Ziyuan
    Shen, Zhan
    Yan, Maojun
    ACTA OCEANOLOGICA SINICA, 2022, 41 (08) : 129 - 136
  • [32] Optimized ultrasound-assisted dispersive liquid-liquid microextraction for simultaneous trace multielement determination of heavy metals in environmental water samples by ICP-MS
    Wang, Xiaojun
    Chen, Jingjing
    Zhou, Ying
    Wang, Lijia
    TOXICOLOGY LETTERS, 2014, 229 : S132 - S132
  • [33] Contribution to the certification of B, Cd, Cu, Mg and Pb in a synthetic water sample, by use of isotope-dilution ICP–MS, for Comparison 12 of the International Measurement Evaluation Programme
    J. Diemer
    C. Quétel
    P. Taylor
    Analytical and Bioanalytical Chemistry, 2002, 374 : 220 - 225
  • [34] Investigation of Adverse Effect of Coexisting EDTA during Chelating-resin Solid Phase Extraction on the Determination of Trace Elements in Environmental Water Samples by ICP-MS
    Fujimori, Eiji
    Kumata, Hidetoshi
    Umemura, Tomonari
    BUNSEKI KAGAKU, 2021, 70 (1-2) : 31 - 37
  • [35] Extraction induced by microemulsion breaking as a novel tool for the simultaneous determination of Cd, Mn, Pb and Sb in gasoline samples by ICP-MS and discrete sample introduction
    Vicentino, Priscila O.
    Cassella, Ricardo J.
    Leite, Diego
    Resano, Martin
    TALANTA, 2020, 206
  • [36] Extraction induced by microemulsion breaking as a novel tool for the simultaneous determination of Cd, Mn, Pb and Sb in gasoline samples by ICP-MS and discrete sample introduction
    Vicentino P.O.
    Cassella R.J.
    Leite D.
    Resano M.
    Talanta, 2020, 206
  • [37] Estimation of uncertainties of the method to determine the concentrations of Cd, Cu, Fe, Pb, Sn and Zn in tomato paste samples analysed by high resolution ICP-MS
    Yenisoy-Karakas, Serpil
    FOOD CHEMISTRY, 2012, 132 (03) : 1555 - 1561
  • [38] Determination of Cd, Pb, Zn and Cu in sediment compartments by sequential extraction and isotope dilution inductively coupled plasma mass spectrometry (ID-ICP-MS)
    Gardolinski, PCFC
    Packer, AP
    de Almeida, CR
    Giné, MF
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2002, 13 (03) : 375 - 381
  • [39] Development of an accurate, sensitive, and robust isotope dilution laser ablation ICP-MS method for simultaneous multi-element analysis (chlorine, sulfur, and heavy metals) in coal samples
    Sergei F. Boulyga
    Jens Heilmann
    Thomas Prohaska
    Klaus G. Heumann
    Analytical and Bioanalytical Chemistry, 2007, 389 : 697 - 706
  • [40] Development of an accurate, sensitive, and robust isotope dilution laser ablation ICP-MS method for simultaneous multi-element analysis (chlorine, sulfur, and heavy metals) in coal samples
    Boulyga, Sergei F.
    Heilmann, Jens
    Prohaska, Thomas
    Heumann, Klaus G.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2007, 389 (03) : 697 - 706